Title: Categorizers CAT Team Workshop
1Categorizers (CAT) Team Workshop 2007-03
2OUR AGENDA!
- Workshop Goals
- Today's Quotes Its About Time!
- ORPS Trending
- Define
- ORPS World DOE Proposed Changes
-
- Programmatic Bins
- Meeting Evaluation and Wrap-up
- Â Â Â Â Â
3CAT Team Workshop
- Workshop Goals
- To EVALUATE and CONTINUOUSLY IMPROVE the BNL
Occurrence Reporting Program.
- To MAINTAIN a baseline categorization process
such that reportability decisions are both VALID
and CONSISTENT.
- To REVIEW/ EVALUATE data to determine if repeat
events should be identified as potentially
RECURRING occurrences.
- To PROMPT (via accurate categorization) DEEP and
LASTING value-added CHANGE, which results in new
ways of THINKING and ACTING.
-
CAT
4Today's Quotes Its About Time!
- Better three hours too soon, than one minute too
late.     - William Shakespeare
- Killing time is like committing slow
suicide.     - Anonymous
- Time is the wisest counselor of all.     -
Pericles
- Don't let yesterday use up too much of
today.     - Will Rogers
- You cannot do a kindness too soon, for you never
know how soon it will be too late.     - Ralph
Waldo Emerson
- Time is what we want most, but what we use
worst.     - William Penn
- Years of love have been forgot,In the hatred of
a minute.     - Edgar Allan Poe
- The common man is not concerned about the passage
of time, the man of talent is driven by it.  -
Shoppenhauer
5BNL ORPS by Calendar Year Report Submitted
As of 11/30
6Event Categorizer Electronic Entries
74th Qtr FY 07
84th Qtr FY 07
9ORPS Corrective Action StatusFY 2007 (End of
Month)
10CY 2007 SCBNL Reports (22)
- 02/04 KK, Minor Electrical Fire in Building
1007-W
- 02/09 PB, Torn ligament on left thumb from
moving boxes for office relocation
- 02/12 PB, Overheated Bearing on Main Magnet
Water Supply Pump
- 03/05 KS, Small brush fire
- 03/13 SM, Smoldering debris near Cooling Tower
4 by B912A
- 03/15 SM, Plumber Injures Tooth
- 03/19 MD, B-197 evacuation due to fire alarm
- 05/01 AP, Contamination in HFBR fuel vault
- 05/02 AP, Minor brush fire in Front of building
911
- 05/03 AP, Minor fire in ventilation system at
NSLS
- 05/05 AP, Cigarette butt results in smoldering
mulch bed near B-735
- 05/15 MD, Fire in Building 120 Butt Stop
- 05/24 KS, Brush fire at remote location in the
SE corner of site
- 05/31 MZ, Fire in portable generator during
preventive maintenance
- 06/18 AP, Fractured Finger Tip T-87
-
11CY 2007 SCBNL Reports (22)
- 06/27 KK, Electrical fire inside the cab of
Rescue Vehicle at Building 599
- 06/28 KK, Butt Can Fire at Building 153
- 07/17 KS, B-912A Diesel Engine Exhaust
Ignites a Small Patch of Grass
- 08/09 AP, Smoking air compressor electrical box
_at_ B-902
- 09/28 Al, Motor pool worker injures back while
lifting a forty pound starter
- 10/08 RK, Brush Fire at Dear Leap Road (dirt
road) at North side of RHIC Ring
- 11/14 MZ, Condensate Tank Motor Fire at B-555
-
12CY 2007 ORPS Reports (22)
- Coffee-Room Microwave Oven Fire Causes Building
Evacuation
- Security Patrol Officer Injures Knee
- Copper Sheets Pin Worker Against Work Bench
- Irritant in Air from Cleaning Floor Tile - Bldg
400 Lobby
- Employee Grazed by Truck
- PISA and USQ for DOE review of Waste Management
Facility Documented Safety Analysis
- Firefighter drops exercise weight plate on left
foot causing fracture
- Ungrounded Neutral Discovered in wye connected
output of 13.8kV/208V Transformer
- Laser Status Indicators at the Accelerator Test
Facility (ATF) Not Functioning Properly
- Operational Emergency - Severe Weather
- Cable Fault Causes Power Outage
- Firefighter's Hand Injured during Patient
Transport
- Bunsen Burner Ignites Disposable Lab Coat
- Unexpected Discovery of an Uncontrolled
Electrical Energy Source in Building 490
- Simultaneous Degradation of Fire Alarm System and
Water Supplies for the Apartment Area
- Researcher Contamination (Nitrogen -13)
- Employee Trips and Fractures Left Foot
- Minor Electrical Shock
- Employee Fractures Rib During Pick-up Truck Lift
Gate Operation
13CY 2007 ORPS Reports (22)
- 02 Maintenance
- 03 -- Normal Operations
- 09 -- Emergency Response
- 10 -- Inspection/Monitoring
- 12 -- Research
14CY 2007 ORPS Reports (22)
15CY 2007 ORPS Reports (22)
- A3B1C02 -- Step was omitted due to distraction
- A3B1C03 -- Incorrect performance due to mental
lapse
- A3B2C04 -- Previous success in use of rule
reinforces continued use of rule
16CAT Electronic Entries
- 08/21 KK, Building 830 hot cell door open and
adjacent safe not locked
- 08/23 KK, ERP's LOTO Program questioned in
regard to SBMS requirements
- 08/23 KK, Work Proceeds at HFBR Without BHSO
Approval
- 08/23 KK, Flammable Mat Locker (2) contents
dont match Inventory sheets _at_ BGRR
- 08/27 KK, Material Blown from Building Roof
Causes Minor Damage to Automobiles
- 08/27 KK, Radioactive Samples Freeze Resulting
in Cracked Containers
- 08/29 MD, Small Antifreeze Spill on Pavement
behind B-599
- 08/30 MD, Employee bumps elbow on door at NSLS
- 08/30 AL, Multiple Rad Sources Exposed in
Irradiator during maintenance
- 09/05 SM, Lab Coat Sleeve burned by contact
with Bunsen burner flame, SC3
- 09/06 SM, Bldg 400 Stop Work for less than
Confirmed Imminent Danger
- 09/11 KS, Grounds worker receives minor injury
(from thorn) while trimming trees
- 09/12 KS/ES, Partial Loss of Site Fire Alarm
System, SC3
- 09/12 KS, Exposed Wiring Electrical Hazard in
Building 490, SC3
- 09/12 KS, Worker Exposure to Excessive Noise
During Vacuuming
- 09/13 KS, Research assistant suffers mild
allergic reaction to chemicals
- 09/14 KS, Installation Error in Manufactured
Modular Wall Assembly
- 09/17 MZ, Employee working offsite in Oklahoma
steps in hole and injures ankle
- 09/19 MZ, Employee injures hand closing
elevator _at_ B-911
17CAT Electronic Entries
- 09/21 MZ, Lawn Maintenance Results in AC unit
Falling onto Mower, SC3
- 09/21 MZ, Hydraulic fluid discovered in
elevator shaft casing
- 09/24 MZ, Empty sharps container found in
animal bedding during disposal
- 09/28 AL, BNL retiree injured when arm grazes
door strike plate
- 09/28 Al, Motor pool worker injures back while
lifting a forty pound starter, SCBNL
- 99/28 AL, Researcher Contamination at PET
(Nitrogen -13), SC4
- 09/28 AL, NSLS fuse burns out resulting in
smoke
- 09/28 AL, Contractor vehicle spills hyd fluid
onto pavement in front of B-911
- -------------------------------------1st QTR, FY
08------------------------------------------------
-----------------------
- 10/01 ES, Trip/fall when walking in grass
results in ankle fracture, SC3
- 10/08 RK, Suspicious suit case outside B555 -
precautionary evacuation
- 10/08 RK, Brush Fire at Deer Leap Road (dirt
road) at North side of RHIC Ring, SCBNL
- 10/11 RK, Worker not feeling well was
transported to local hospital and released
- 10/17 SM, Senior Stationary Engineer incurs
muscle strain
- 10/17 SM, Auto Truck Mechanic incurs contusion
to elbow
- 10/17 SM, Admin assist incurs contusion to heal
of hand
- 10/18 SM, Admin assist climbing stairs and
tripped, resulting in a bruised knee
- 10/22 KK, ground near the Southgate borrow pit
- 10/22 AL, Loss of Am-241 Source, less than an
accountable quantity
18CAT Electronic Entries
- 10/25 KK, Jars of Environmental Soil Samples
Arrives at Analytical Laboratory Damaged
- 10/29 MD, Worker cuts Fingers at Central Shops
- 10/30 MD, Employee Injures Hand While Using
Hammer
- 11/06 KS, Minor (most editorial) Deficiencies
Identified in ERD Operating Procedures
- 11/06 KS, Worker injury (minor contusion) from
falling picture frame
- 11/07 KS, ITD employee tripped on a gas/water
access pipe and fell to the ground
- 11/09 KS/ES, Contaminated Wire Identified
During Routine Masslinn Survey at BGRR
- 11/14 MZ, Condensate Tank Motor Fire at B-555,
SCBNL
- 11/15 MZ, Bare Deenergized Electrical leads
discovered during Tier I inspection
- 11/15 MZ, Guest researcher brings liquid
nitrogen onsite in personal vehicle
- 11/15 MZ, Minor elbow injury at NSLS when
worker contacts tool chest
- 11/16 MZ, Burst disc ruptures on liquid
nitrogen dewar before relief valves
- 11/18 MZ, Contractor rigger climbs over rad
shielding wall at C-AD
- 11/20 AL, Work package review identifies lack
of compliance with procedure
- 11/21 AL, Shock, Near miss to an occupational
injury, SC 3
- 11/26 AL, Radio controlled model airplane hits
exterior wall of building
- 11/28 AP, Non work related illness
- 11/29 AP, Discovery of contaminated tape on
pipe in the building 811 yard
- 11/30 AP, Minor Back Strain from Material
Handling in B-479
19CAT Electronic Entries
- 12/04 MZ, Police Officer re-injures shoulder
opening trailer
- 12/04 RK, Worker falls walking on wooden pallet
and bruises elbow outside B1000P
- 12/05 RK, 1 quart spill of vehicle battery acid
on pavement outside B860
20Assessment of BSA Contractor Assurance Program
- Problem Statement Event Categorizers indicated
that they use discretion relative to entering
events/issues into the database this may be due
in part to the lack of clear standards for
defining events/issues below SCBNL. - Â
- Action 1 In collaboration with the BNL Event
Categorizers, define process of recording events/issues (E/I), which shall be recorded in
the E/I database. -
- Action 2 Revise the QMO Event Categorizers
Procedure to include the process that will define
recorded in the E/I database.Â
21Proposed Revision of DOE M 231.1-2, Occurrence
Reporting Criteria HS-30 is reviewing and fina
lizing proposed changes to the occurrence
reporting criteria. Will submit for REVCOM
review in early 2008.
- Separate and clarify the Criteria for Fires and
Explosions.
- New Criteria for Hazardous Electrical Energy
Control using the Electrical Severity Measurement
Tool and for Other Hazardous Energy Control.
- Technical Safety Requirements (TSR) - revised to
remove criticality
- Criticality Safety revised to capture TSR
violations
- Facility Operations revised
- Management Concerns revised
22Proposed Revision of DOE M 231.1-2, Occurrence
Reporting Criteria (contd)
Near Misses - Revised Definition
10 (3) 1-3 A near miss to an otherwise ORPS
reportable event, where something physically
happened that was unexpected or unintended and
significant consequences were avoided only by
chance because either a) no controls or prote
ctive equipment were in place to prevent more
severe consequences, or b) the controls or pro
tective equipment were ineffective.
The significance category assigned to the near
miss should be based on an evaluation of the
potential risks and planned or anticipated
corrective actions. The proposed changes are int
ended to correct known reporting problems and
enhance the Corporate Safety Indicator Process.
23 Programmatic Bins
- Personnel Contamination
- Medical Department
- NSLS
- Physics
- CA-D
- BGRR Project
- Plant Engineering
- Utilities Struck
- Material Transportation
- Electrical Shock Hazards
- Material Handling Issues
- Waste Management
- Chemistry
- Environmental Restoration
- Railroad Tracks
- New Construction
- Noise
-
- Site Fire Alarm System (new)
- Butt Fires (new)
- CFN (new)
24Programmatic Review
- Personnel Contamination 2006
- 02/23 Personnel Cont at Building 901
- 03/22 Cont Detected on Employee's Shoes at PET
- 03/28 Cont of two workers at B-801 during
removal of BLIP target filter
- Personnel Contamination 2007
- 04/26 F-18 finger contamination at PET
- 09/28 Researcher Contamination at PET, B-901
(Nitrogen -13), SC4
-
-
25Programmatic Review
- Medical department, 2006
- 03/07 Rad Cont Outside a Controlled Area at
B-490 (SC3)
- 03/10 Survey Meter/Frisker Taken Outside
Controlled Area _at_ B490
- 03/13 PB, Shock from terminal in legacy
installed light timer (SC4)
- 03/28 Cont of two workers _at_ B801 during removal
of BLIP target filter
- 05/19 Cont found outside a posted area _at_ B490
- 07/31 Trit cont on unposted benchtop in a
posted RMA at B490
- 08/24 Painter's spackling knife contacts aband
live electrical wiring _at_ 490
- 11/16 KK, Contamination at PET Facility, (SC3)
- 10/31 BLIP cooling water leak detection system
did not function during testing
- Medical department, 2007
- 04/26 F-18 finger contamination at PET
- 05/16 Medical Student Passes Out after seeing
blood at B-490
- 05/16 Employee lacerates arm while cleaning a
microtome at B-490
- 05/22 First-degree chemical burn due to small
hole in glove _at_ B-490
- 07/05 Building 801 D Tank Leak, 5mL
- 09/12 Exposed Wiring Electrical Hazard in
Building 490, SC3
- 09/24 Empty sharps container found in animal
bedding during disposal
26Programmatic Review
- NSLS, 2006
- 02/21 X17C Laser Procedure Violation (Door left
open while laser in operation)
- 05/08 Improper work sequence during lead
shielding removal at beam line
- 06/09 XSXD Power Supply Shut-off Failure
- 07/17 Chemical Spill in Wet Chemistry
Laboratory (SC3)
- 08/21 AL/ES, Accidental cutting of energized
power tool line cord (SC3)
- 11/16 Spent Fluorescent Bulbs Found Outside
Waste Storage Area
-
- NSLS, 2007
- 05/03 Minor fire in ventilation system
- 06/12 Aluminum plate pinches beamline User
finger tips
- 07/03 Employee Sustains Injury to Ankle
Tripping on Stairs
-
27Programmatic Review
- Physics, 2006
- 07/07 Employee fractured metatarsal after
tripping over rug/mat
- 08/09 Stop Work Order issued due to antennae at
edge of B510 roof
- Physics, 2007
- 06/11 Improper Status provided by Laser/Shutter
Indicators at ATF, SC3
- 10/01 Trip/fall when walking in grass results
in ankle fracture, SC3
-
28Programmatic Review
- CA-D, 2006
- 03/06 Discovery of Radiation Monitor in
Interlock-Bypass-Mode (SC3)
- 03/29 Lack of admin approval (non-safety
related) for NASA NSRL experiment
- 04/14 400 Amp Electrical Switch Failure (OE,
SC2, SC4)
- 05/04 CA-D Chipmunks read high and alarms at a
lower dose rate than intended
- 06/02 onto the workers pant-leg _at_ RHIC
- 06/09 3 gals of heat transfer fluid (oil)
spilled on Storage Yard pavement by B-924
- 07/20 Pulling cable along floor results in back
strain
- 08/14 200 gal spill from 902 Cooling Towers
to parking lot and grass
- 08/21 Leg laceration while descending ladder at
B1005
- 09/05 Non-standard installation of electrical
disconnect temp wiring (SC3)
- 09/13 Trip on stairs results in 1 qt. spill
of H2SO4 from battery at B901A
- 10/12 Worker hit in head/injured by shelf while
moving a workbench
- 11/02 Fire Protection Impairment Process Not
Properly Followed _at_ B1004B
- 11/06 Man lift damaged during tree cutting
operations
- 11/08 Loose 120 VAC wires on a terminal block
results in sparking
- 11/27 Minor finger laceration
29Programmatic Review
- CA-D, 2007
- 05/02 Minor brush fire in Front of building
911
- 05/10 Power Supplies for Booster to AGS trip
- 05/15 Microwave fire in Building 1005, SC3
- 08/09 Hand caught in freight elevator door at
911, SC4
- 09/19 Employee injures hand closing elevator at
911
- 11/18 Contractor rigger climbs over rad
shielding wall at C-AD
- 12/04 RK, Worker falls walking on wooden pallet
bruises elbow outside B1000P
30Programmatic Review
- BGRR Project, 2006
- 08/03 Removal of fuel anchor (BGRR) not
approved by work procedure
- 09/26 Cont (80, 000 dpm) found outside the BGRR
RCA (SC3)
- BGRR Project, 2007
- 07/20 5,000dpm found on Workers Glove at BGRR
-
-
31Programmatic Review
- Plant Engineering, 2006
- 01/27 Burning Cotton Apron In PPE/Tool Bag
Causes Evac _at_B197 (SC3)
- 05/10 Vehicle window damaged during concrete
sidewalk removal work (SC3)
- 06/16 Asbestos discovered during demolition of
B-422
- 10/13 Silica Exposure During Concrete Crushing
Machine Operation, (SC3)
- 12/05 PE groundskeeper received a minor injury
to the chin
- 12/13 Pump leak results in 100 gal spill of
propylene glycol _at_ B729
-
- Plant Engineering, 2007
- 09/21 Lawn Maintenance Results in AC unit
Falling onto Mower, SC3
32Programmatic Review
- Utilities struck, 2006
- 08/08 Fiber-Optic Cable inadvertently severed
at B707A, HFBR pump house swgear
- Utilities struck, 2007
33Programmatic Review
- Material Transportation, 2007
-
34Programmatic Review
- Electrical Shock, 2006
- 03/13 - Shock from terminal in legacy installed
light timer (SC4)
- 09/06 AP, Table lamp electrical fault at
apartment 4B results in finger tingle
- Electrical Shock, 2007
- 07/20 Tech receives minor electrical shock when
B-452 struck by lighting
- 11/21 Shock, Near miss to an occupational
injury, SC 3
35 Programmatic Review
- Material Handling Issues, 2006
- 01/17, Tennelec smear counter falls during
transport, (SC3)
- 06/30, Computer server unit falls out of BNL box
truck grazing workers leg (SC3)
- 07/20, Pulling cable along floor results in back
strain
- 08/28, During transport a forklift dropped a
secured aerial lift (SC3)
- Manual Material Handling Issues, 2007
- 09/28 Motor pool worker injures back while
lifting a forty pound starter, SCBNL
- 11/30 Minor Back Strain from Material Handling
in B-479
-
36 Programmatic Review
- Waste Management, 2006
- 01/20 USQ on rusting HEPA exhaust stack _at_ B860
(SC3)
- 02/22 Lapse in USQ training qualification
- 08/04 HFBR Dumpster alarms BNL Radiation Truck
Monitor (SC3)
- 08/16 Walk through of HFBR identifies
rad/non-rad items that are not segregated
- Waste Management, 2007
-
-
-
37 Programmatic Review
- Chemistry, 2006
- 01/17 Energ ckt disc in cut conduit in floor
slab _at_ B555, (SC3)
- 02/23 Personnel Cont at Building 901
- 03/22 Cont Detected on Employee's Shoes at PET
- Chemistry, 2007
- 08/02 BNL employee trips on asphalt lip near
B-555 and bruises knee
- 10/08 Suspicious suit case outside B555 -
precautionary evacuation
- 11/14 Condensate Tank Motor Fire at B-555,
SCBNL
38 Programmatic Review
- Environmental Restoration Projects, 2006
- 09/22 HFBR air conditioning water pump seal
leak (SC3)
- 10/30 Flaw in ERP calculation of total
recordable injury statistics
- 11/30 SM, Failure to Maint Config Control of
DOE-SER specified Documents (SC3)
-
- Environmental Restoration Projects, 2007
- 05/01 Contamination in HFBR fuel vault
- 06/14 Tool Bag at HFBR Measures above Rad
Release Limits
- 07/09 Untrained Personnel Entry into Confined
Space at HFBR
- 07/17 Inappropriate Change to Work Procedure at
HFBR
- 08/23 Work Proceeds at HFBR Without BHSO
Approval
-
39Programmatic Review
40Programmatic Review
- New Construction, 2006
- 04/21 Sub incurs severe laceration of leg at
CFN (SC3)
- 07/31 A/C mechanic cuts arm at RSB Construction
Site
- New Construction, 2007
41Programmatic Review
- Noise, 2006
- 01/18 Noise over exposure per ACGIH TLV _at_ B902
(SC3)
- 03/07 Over-exposure to noise hazard _at_ Motor
Pool Repair Facility (SC3)
- Noise, 2007
- 09/12 Worker Exposure to Excessive Noise During
Vacuuming
42 Programmatic Review
- CFN, 2007
- 05/04 Discovery of smoldering mulch bed on
south side of CFN
- 08/01 Rain water intrusion into CFN
- 09/14 Installation Error in Manufactured
Modular Wall Assembly
43 Programmatic Review
- Site Fire Alarm System
- 06/14 Site-wide Fire Alarm Communications
Malfunction, SC4
- 07/05 Site Fire Alarm System Loop 1 Bldgs not
Reporting
- 08/17 Loss of BNL Fire Alarm Loops to
Firehouse
- 09/12 Partial Loss of Site Fire Alarm System,
SC3
44 Programmatic Review
- Butt Fires, 2007
- 05/02 Minor brush fire in Front of building
911
- 05/04 Discovery of smoldering mulch bed on
south side of CFN
- 05/15 Fire in Building 120 Butt Stop
- 05/24 Brush fire at remote location in the SE
corner of site
- 06/15 Issued Fact-finding/Causal
Analysis/Preventive Actions No. QMO-2007-0001,
ATS 3788
- 06/28 Butt Can Fire at Building 153
- 10/08 RK, Brush Fire (cause unknown) at North
side of RHIC Ring, SCBNL
45CAT Team Workshop
- CAT Team Action Item Review