Title: Pumping Systems Division
1Pumping Systems Division Olive Branch, Mississippi
2Fabrication Shop
3Fabrication Shop
4Control Panel Shop
5Powder Coating Facility
6Pump Shop
7Test Pit Facility
8Test Pit Facility
9National Packaged SystemVFD Pump
StationsareAvailable in these configurations
Centrifugal Pumps
Submersible Pumps
10National Packaged System Standard Pump Station
Models
- NPSII Multiple Main Pumps ( Indoor )
up to 1000 gpm max. 50hp -
- NPSIII Multiple Main Pumps w/PM (Outdoor)
up to 1000 gpm max. 75hp -
- NPSIV Two Main Pumps w/PM
up to 2000 gpm max. 75hp -
- NPSV Two,Three,Four Main Pumps w/PM
up to 4000 gpm max. 100hp -
- NPSVI Two, to Six Main Pumps w/ PM
up to 6000 gpm max. 125hp -
- NPSR Retrofit for VFD Control Panels
all applications max. 125hp -
- NPSX Custom Packages
all applications max. 125hp
11(No Transcript)
12NPSII Multiple Main Pumps, VFD Pump Station Flow
Range 250-1000 GPM 25HP 50 HP Main Pump
- Standard Features
- VFD Drive with on board processor
- Main Circuit Breaker Disconnect
- U.L Listed complete pump station
- Start up Ramp Restart
- Lightning Arrestor
- Low level or low inlet safety
- Bypass Contactor ( 3 phase only )
- Cla-Val Pressure Relief Valve
- High Low discharge safety
- High pump temp safety ( centrifugal )
- Deep well start-up program capability
- Available Options
- Single Phase Capability
- Powder-coated aluminum, lockable station
- enclosure
- Flow meter with totalizer
- Lake Level control
- Station Heater
13(No Transcript)
14NPSIII Multiple Main Pumps w/PM Pump, VFD Pump
Station Flow Range 300-1000 GPM 30HP 75 HP Main
Pump with 5HP or 15HP PM Pump
- Standard Features
- NEMA 12 Enclosed Drive with on board
- processor and heat exchanger
- Main Circuit Breaker Disconnect
- U.L Listed complete pump station
- Start up Ramp Restart
- Lightning Arrestor
- Low level or low inlet safety
- Bypass Contactor ( 3 phase only )
- Cla-Val Pressure Relief Valve
- High Low discharge safety
- High pump temp safety ( centrifugal )
- Deep well start-up program
- capability
- Available Options
- Single Phase Capability
- Powder-coated aluminum, lockable station
- enclosure
- Flow meter with totalizer
- Lake Level control
- Station Heater
15(No Transcript)
16NPSIV Two Main Pumps w/ PM Pump, VFD Pump
Station Flow Range 600-2000 GPM 2x30 HP 2x75HP
Main Pumps w/ 5hp PM Pump
- Standard Features
- Main Circuit Breakers HMCP Motor Protection
- Lightning Arrestor
- Low level or low inlet Safety
- NEMA 4 Enclosed Drive with Heat Exchanger
- U.L Listed complete pump station
- Reversing Contactors
- ClaVal Pressure Relief Valve
- Start-up Ramp Restart
- Emergency Bypass
- High Low discharge safety
- High pump temp safety ( centrifugal )
- Flow meter with Totalizer
- Inlet and Discharge isolation valves
- Integrated filter and Auxiliary Pump Controls
- Deep well start-up program
- capability
- Hand / Off / Auto pump
- control switches
- Two Line DTAM operator
- interface terminal (OIT)
- Available Options
- Power Zone
- Zee-Pipe
- Pump View Remote
- Access software
- Lake level Control
- Station Heater
17(No Transcript)
18NPSV Two, Three, or Four Main Pumps w/PM Pump,
VFD Pump Station Flow Range 1000-4000 GPM 2,3,or
4 x 30HP-2,3,or 4 x 100HP with 5HP PM Pump
- Standard Features
- NEMA 4 Enclosed Drive with Heat Exchanger
- Lightning Arrestor
- Low level or low inlet Safety
- U.L Listed complete pump station
- Reversing Contactors
- Relief Valve
- Start-up Ramp Restart
- Emergency Bypass
- High Low discharge safety
- High pump temp Safety ( centrifugal )
- Flow meter with totalizer
- Emergency Bypass
- Inlet and Discharge isolation valves
- Integrated filter and Auxiliary Pump Controls
- Touch Screen Operator
- interface Terminal
- Available Options
- Power Zone
- Zee-Pipe
- Pump View True Remote Access
- software
- Lake level control
- Station Heater
19(No Transcript)
20(No Transcript)
21(No Transcript)
22(No Transcript)
23(No Transcript)
24(No Transcript)
25NPSVI Two to Six Main Pumps w/PM Pump, VFD Pump
Station Flow Range 1000-6000 GPM
- Standard Features
- NEMA 4 Enclosed Drive with Heat Exchanger
- Lightning Arrestor
- Low level or low inlet Safety
- U.L Listed complete pump station
- Reversing Contactors
- Relief Valve
- Start-up Ramp Restart
- Emergency Bypass
- High Low discharge safety
- High pump temp Safety ( centrifugal )
- Multiple Flow Meter capability
- Emergency Bypass
- Inlet and Discharge isolation valves
- Integrated filter and Auxiliary Pump Controls
- Touch screen Operator
- interface Terminal
- Available Options
- Power Zone
- Zee-Pipe
- Pump View Remote
- Access software
- Lake level control
- Station Heater
Product in development, Projected completion Date
Q402
26NPSR Retrofit Application mainly used for
upgrading control systems while utilizing the
existing pumps and motors. Major Benefit is in
converting existing Deep Well applications to
VFD Operations
27www.nationalpumpcompany.com
www.nationalpumpcompany.com
www.nationalpumpcompany.com
www.nationalpumpcompany.com
www.nationalpumpcompany.com