Transcript and Presenter's Notes

Title: Folie 1


1
Testing- and Calibration Technology Calibration
Software EasyCal
Pressure and Temperature Measurement
2
Screenshot demo-version of a calibration
procedure with software EasyCal
  • Advantages demo-version
  • Interactive presentation with Powerpoint
  • no admin rights are necessary
  • with explanation text and red marks will lead
    through the calibration
  • procedure

Example sheet from demo-version
3
Screenshot demo-version of a calibration
procedure with software EasyCal
EasyCal calibration assistant will lead in 6
steps through the calibration. There are 2
different possibilities of a calibration with
EasyCal.
  • Fully-automated computer aided calibration of
    pressure transmitters with EasyCal. (The
    Pressure controller CPC 8000 automatically
    generates the pressure values given by EasyCal.
    Both measurement values will be given
    by EasyCal imported to EasyCal and
    evaluated.)
  • Semi-automated computer aided calibration of
    pressure gauges with EasyCal. (The pressure
    values have to set via a pressure source
    (test pump) acc. to the display of the test
    item and confirmed by a mouse-click.)

4
Semi-automated computer aided calibration of
pressure gauges with EasyCal
Application Calibration of a pressure gauge with
accuracy 1,0. As reference item there is a CPH
6200 with accuracy 0,2.
Interface cable
Test item accuracy 1,0
Test-pump to generate pressure
Calibration item accuracy 0,2
5
Semi-automated computer aided calibration of
pressure gauges with EasyCal
General A calibration is done by a direct
comparison between the measured values of the
calibration object (test item) and those of the
reference or working standard, which is directly
or indirectly traceable to a national
standard. Calibration procedure The pressure
values of the Test Cycle will be calculated by
the Software EasyCal. Each time the recommended
pressure value has to be set via a pressure
source (test pump) acc. to the display of the
test item. (Notice the pressure should not
over-shoot to detect the hysteresis of the test
item) . Is the respective pressure set, user
informs the software via a mouse-click/Enter-key
and the value of the reference/CPH 6200 is read
in via the RS-232/USB interface and stored next
to the recommended pressure value, which is
currently shown by the test item. After all
pressure values are likewise produced the
software automatically do the evaluation
(calculation of uncertainty and hysteresis),
stores the data in an ACCESS-Databank and a
printable Certificate is produced, which can be
designed by the user (own Logo, etc). if
needed the recommended pressure values can be
changed.
6
Semi-automated computer aided calibration of
pressure gauges with EasyCal
  • Set Powerpoint to ltpresentationgt
  • Please press the red circles with your mouse
    button

7
(No Transcript)
8
1. step Please fill in the basic data
9
2. step Choice of a reference instrument
Select the reference instrument
10
3. step Choice of a calibration item
Select the calibration item
How to set up a new calibration item, will be
shown in the appendix
11
4. step Data for calibration procedure
Select the calibration method
990
5
The values of measurement points will be defined
automatically. The generation of these points are
influenced by the range and accuracy of the test
item.
12
5. step Calibration procedure
Calibration circuit
Calibration method Read measurement value on
test item. The set value is set on the test item
and is compared with the actual value of the
reference item.
13
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
14
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
15
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
16
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
17
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
18
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
19
5. step Calibration procedure
defined hold-time runs down
20
5. step Calibration procedure
definedhold-time runs down
21
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
22
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
23
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
24
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
25
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
26
5. step Calibration procedure
Calibration circuit
Generate pressure with test pump. If set value is
reached on calibration item (test item), press
the OK button
27
5. step Calibration procedure
All measurement values of the test item have the
required accuracy of 1,0
28
5. step Calibration procedure
29
6. step Store measurement data and create test
certificate
Notes can be add, which will be shown in the
calibration report.
30
6. step Store measurement data and create test
certificate
31
6. step Store measurement data and create test
certificate
32
Your company logo
Here could your company logo be placed
33
(No Transcript)
34
Appendix
1.) Fully automated calibration with EasyCal 2.)
Installation of a new calibration item 3.) The
calibration item does not match the calibration
class 4.) Product Support
35
1.) Fully-automated computer aided calibration of
pressure transmitters with EasyCal.
Up to the 5. step (the calibration procedure),
the fully-automated calibration runs analog to
the semi-automated procedure, but the set values
are generated automatically by the pressure
controller and the measurement values are
stored.The calibration report is also created
automatically.
36
1.) Fully-automated computer aided calibration of
pressure transmitters with EasyCal.
Pressure supply (110 FS)
Test item
multimeter (with shunt)
PC with EasyCal
IEEE-interface cable
CPC 8000
Calibration procedure The CPC 8000 will control
automatically all pressure steps (one after
another), recommended / calculated by the
Software EasyCal. Is one pressure controlled and
stable the software will read the signal of the
test item via the multimeter and will give the
signal to start to control the next
pressure. After all pressure values are likewise
produced the software automatically do the
evaluation (calculation of uncertainty and
hysteresis), stores the data in an
ACCESS-Databank and a printable Certificate is
produced.
37
2.) Installation of a new calibration item
Window calibration item
38
2.) Installation of a new calibration item
to essential characteristics
39
2.) Installation of a new calibration item
to output signal
40
2.) Installation of a new calibration item
to specified test cycle
41
2.) Installation of a new calibration item
The values of the measuring points are created
automatically to chosen measurement range.The
quantity of the measuring points are created to
chosen accuracy
42
2.) Installation of a new calibration item
User interface calibration item
New calibration item is installed and can be
chosen
43
3.) The calibration item does not match the
calibration class
The calibration item does not match the
calibration class of 1. It has a tolerance of
1.1. The calibration has to be stopped and the
calibration item has to be adjusted.After
adjustment, the calibration item can be
calibrated again.
44
4.) Product Support
For product order please contact
Heike ScherfGB-PI-PKTel 09372 / 132-473Fax
09372 / 132-217E-Mail h.scherf_at_wika.de
Daniela Berberich GB-PI-PKTel 09372 / 132-9986
Fax 09372 / 132-217E-Mail d.berberich_at_wika.de
For product information please contact
Christian Elbert GB-PI-PKTel 09372 /
132-299Fax 09372 / 132-217E-Mail
c.elbert_at_wika.de