Title: July 8 2003, FPD integration meeting, Carlos Avila


1
  • FPD noise pattern on AFE is due to TPP layout
  • Location of GNDA layer seems to be the cause of
    getting noise on AFE.

TPP layer design
One channel basic circuit
2
Tests on AFE phase 5 stand
Primary ground out
  • Used an empty TPP board and added transformers
    to only one ribbon connector.
  • Took out the primary ground of transformers.
  • extended one ribbon cable from pw08 to phase 5
    test stand
  • Tested different ground configurations

3
PW08 cable connected to MCM4 on phase 5 stand
9.0
MCM4
2.5
MCM4
3.5
MCM4
4
RMS on MCM2 with pw08 cable connected on MCM4
10.0
MCM2
1.6
MCM2
3.0
MCM2
5
Another Possibility is not connecting primary
ground to any layer, just connect primary ground
to the ground on input ribbon cable.
4.0
MCM4
MCM4
July 3
July 6
2.0
MCM2
6
SUMMARY AND CONCLUSIONS
  • Two possible TPP configurations to reduce noise
  • Not connecting primary ground to a layer plane
    reduces noise pickup on different lines.
  • Waiting for Collision Hall access to perform
    tests at Pw08
  • If we want new boards made, it would take about
    one week to get new Gerber file if we just swap
    VBB and GNDA layers. It would take about a month
    to make major modifications time of making the
    boards time to stuff them.

We could also just rewire the board