Title: RELIABILTY AND OF EDDY CURRENT TESTING
1RELIABILTY AND OF EDDY CURRENT TESTING
- ANMOL BIRRING
- NDE ASSOCIATES, INC
- WWW.NDE.COM
2MY PERSONAL EXPERIENCE
- PERFORMING ECT FOR OVER 15 YEARS
- WORKED IN SEVERAL PETROCHEMICAL AND FOSSIL PLANTS
- CONDUCTED ECT TRAINING IN USA, KOREA, JAPAN,
MEXICO, TAIWAN
3PAPER ADDRESSES
- INSPECTION IN PETROCHEMICAL PLANTS
- INSPECTION OF HEAT EXCHANGER TUBING
4TUBING INSPECTION METHODS
5CONVENTIONAL ECTNON-FERROMAGNETIC TUBING
- STARTED IN 1950s
- FIRST MAJOR APPLICATIONS BY NAVY NUCLEAR
- STEAM GENERATOR INSPECTIONS IN THE 1960s
6ECT INSPECTION
7DEFECT TYPES
8OD CRACK
9ECT STRIP CHART
10CALIBRATION
11ECT INSPECTION
12ID PITTING BRASS TUBING
13FINAL RESULTS
14DEFINITION - RELIABILTY
- POD PROBABABILTY OF DETECTION. MUST BE HIGH
- POFA PROBABILTY OF FALSE ALARMS. MUST BE LOW
- RELIABILTY POD x (1-POFA). MUST BE HIGH
- ACCURACY SIZING ERRORS
15EPRI AND SHELL TESTS ON RELIABILTY
- POD CAN VARY 50 TO 95
- POFA CAN VARY 0 TO 20
- RELIABILTY POD x (1-POFA) CAN VARY 40 TO 90
- TECHNICIAN DEPENDENT
- NOT EQUIPMENT DEPENDENT
16PETROCHEMICAL VS. NUCLEAR
- NUCLEAR - WELL DEFINED MATERIALS
- NUCLEAR WELL DEFINED DAMAGE MECHANISMS
- PETROCHEMICAL RANGE OF MATERIALS AND DAMAGE
MECHANISMS WE HAVE OVER 150 CAL TUBES AND WE
STILL ADD
17MAJOR PROBLEM WITH ECT INSPECTIONS
- LARGE VARIATION AMONG TECHNICIANS IN RELIABILTY
AND ACCURACY
18WHAT CAUSES SUCH VARIATIONS
- EDUCATION ?
- TRAINING ?
- TESTING ?
- CERTIFICATION ?
- APTITUDE ?
19CERTIFICATIONS AND EXPERIENCE
- LEVEL II AND III DO NOT MEAN ANYTHING IN TUBE
TESTING - PAST EXPERIENCE MAY NOT BE OF MUCH SIGNIFICANCE
20EDUCATIONHOW MUCH ?
- MUST HAVE HIGH SCHOOL EDUCATION
- BASIC MATH SKILLS MUST BE GOOD
- COMPUTER SKILLS ARE A NECESSITY
- Note I have run into students who do not know
what is 20 of 80 - This is the problem of our
high school students
21TRAINING
- GENERAL ECT TRAINING - OK
- SPECIFIC ECT TRAINING
- PRACTICAL ECT TRAINING
22GENERAL TRAINING
- MUST UNDERSTAND IMPEDANCE PLANE
23SPECIFIC TRAININGTECHNIQUE SELECTION
- CONVENTIONAL ECT
- REMOTE FIELD ECT
- IRIS
- MFL
- TECHNIQUES AND LIMITATIONS
24SPECIFIC TRAINING
- SELECTION OF PROBE FREQUENCY AND SIZE
- CALIBRATION TUBE MUST BE SAME MATERIAL AND SIZE
- HOW TO VERIFY TUBE MATERAIL
- DETERMING ECT FREQUENCY WITHOUT KNOWING MATERIAL
CONDUCTIVITY
25VERIFY TUBE MATERIAL
26PRACTICAL ECT TRAININGMUST ADDRESS REAL WORLD
PROBLEMS
- MATERIALS
- DEFECT TYPES
- METALLIC DEPOSITS
27MATERIALS
- STAINLESS STEEL, HASTELLOY, INCONEL
- AD. BRASS, Cu-Ni Alloys MOST DIFFICULT
- TITANIUM
- ALLOY 2205
28DEFECT TYPES
- PITTING
- CRACKING AXIAL AND CIRC
- WALL LOSS
- DAMAGE AT SUPPORTS
29METALLIC DEPOSITSWEAKEST AREA
- METALLIC DEPOSITS IN TUBES CAN JUST LOOK LIKE
DEFECT SIGNALS - THIS ARE IS RARELY ADDRESSED IN ANY TRAINING
- MAJOR CAUSE OF POFA
30METALLIC DEPOSITS
31ID GROOVE
32METALLIC DEPOSITS CAN LOOK LIKE ID DEFECTS
33SIZNG ACCURACY
- ASME CAL CURVE IS NOT ACCURATE
- ECT PHASE DEPENDS BOTH ON DEFECT DEPTH AND
DIAMETER
34CURRENT PRACTICAL TRAINING
- BASICALLY THERE IS MINIMAL PRACTICAL TRAINING
- LIMITED TO ASME CAL TUBES
35PRACTICAL TRAINING
- MUST BE ON ACTUAL DATA
- MULTIPLE ID PITS
- DEFECTS UNDER SUPPORTS
- METALLIC DEPOSITS
- RANGE OF MATERIALS
36TRAINING ON TEST BUNDLESNOT EFFECTIVE
- THIS APPROACH IS VERY LIMITED
- LIMITED SAMPLES
- LIMITED DEFECTS
37WHAT ABOUT TESTS ON BUNDLES ?LIMITED TESTS
- MOST OF THEM HAVE MACHINED FLAWS
- MOST OF THEM TEST CAPABILTY TO TEST UNDER
SUPPORTS
38WHAT IS NEEDED ?
- MORE INTENSE PRACTICAL TRAINING ON ACTUAL DATA
OVER 10,000 SIGNALS - TESTING ON ACTUAL TUBE DATA
39PRACTICAL TEST ON ACTUAL DATA20 SIGNALS EACH
- MULTIPLE ID DEFECTS IN BRASS
- ID DEFECTS IN BRASS
- OD DEFECTS IN BRASS
- WEAR AT SUPPORTS
- CRACKS AT SUPPORTS
- METALLIC DEPOSITS
- VIBRATION DAMAGE
40CONCLUSIONS
- ECT IN PETRMOCHEMICAL PLANTS IS CHALLENGING
- RANGE OF MATERIALS
- VARIETY OF DAMAGE MECHANISMS
- PRACTICAL TRAINING AND TESTING THAT ADDRESSS
THESE ISSUES IS THEREFORE REQUIRED
41FINALLY !!
- IT BOILS DOWN TO THE ATITUDE OF THE INSPECTOR
- WILLINGNESS TO LEARN
- SELF MOTIVATON
- INTEGRITY
42FOR MORE INFORMATIONWWW.NDE.COM