Title: Cooking Measures


1
Cooking Measures
  • Hot Food Holding Cabinets, Steamers, and Fryers
  • RTF Meeting 5/5/2009

2
Project Goal
  • Goal Verify the electrical savings and cost
    difference between standard units (CEE Tier
    I/Energy Star) and high efficiency (Tier II)
    units by using a developed energy savings
    spreadsheet for all three measures.

3
Project Timeline/History
  • Started in October of 2008
  • First Goal was to try and determine current
    standard practice
  • We hit the streets and determined large percent
    roughly 50 of market is used. However, we
    decided not to include based on discussion with
    RTF. Re-sales/Efficiency/Cost
  • We then pursued new equipment and found some
    surprising data.
  • Based on Discussion with Vendors and Best in
    Class Study we found that a large percent of new
    equipment being purchased is already Energy Star
    or CEE Tier I rated.
  • We believe over 75 of new standard fryers and
    HFHCs are Energy Star, however approximately only
    30 to 40 of steamers are Energy Star (Boiler
    Based vs. Connectionless)

4
Energy Baseline
5
Steamers Baseline (Actual)
  • Approximately 30 to 40 of Market is
    Connectionless (Discussion with Vendors)
  • Best in Practice Report does not include AccuTemp
    (Developer of Connectionless Unit, Large
    portion of Connectionless Market)
  • FSTC believes that approximately 60 of
    compartment steamers can be replaced with
    connectionless (Increased Potential)

6
Project Timeline/History
  • EMP2, Inc. then developed a Tier II rating and
    incremental cost for all three measures.
  • HFHC already had a CEE Tier II rating.
  • EMP2, Inc. developed Tier II rating based on
    market penetration, vendor participation, and
    comparison to other Tier II programs.

7
Tier II Development
  • The Tier II was developed from the Energy Star
    list of equipment for Fryers and Steamers. Hot
    Food Holding Cabinets were already divided into
    Tier I and Tier II.
  • The selection process would be one that we could
    implement for both Fryers and Steamers.
  • In general, the efficiencies of Fryers and
    Steamers are broken into Cooking Energy
    Efficiency (HCE for Fryers and CEE for Steamers)
    and Idle Energy Rate (IER) with the two
    parameters not necessarily correlating to one
    another. Therefore our process would try to
    address both components.
  • It was decided that 50 of the top Cooking Energy
    Efficiency and the top 50 of the Idle Energy
    Rate would be the cutoffs, and then this would
    ensure that units within those two ranges would
    be the most efficient units within the population
    in both parameters. Then, the actual efficiencies
    would be adjusted to simpler and more usable
    values (i.e. 80.3 HCE rounded to 83).
  • In addition, Incremental Cost would be determined
    for Fryers, Steamers and Hot Food Holding
    cabinets. There are many factors that affect
    equipment pricing that may or may not be directly
    energy related (i.e. components of computer
    controls, auto lift features) so incremental
    costs has to be determined on an individual
    measure basis and it is useful to compare like
    products from like manufacturers.

8
Fryers
  • Applying the selection process yielded the
    following distribution for Fryers
  • The HCE was rounded down to 83 from the original
    83.7 and then for incremental cost reasons, the
    IER was adjusted from the original 891 IER to 850
    IER.

9
Fryer Incremental Costs
  • Many factors affect the pricing of fryers such as
    computer controls that may increase efficiency
    such as modulating heating elements and the timed
    heating of oil as are present in the Fry Masters
    TC units (Tier II). Some aspects of computer
    controls are not energy efficiency related such
    as language settings, multiple programmable cook
    cycles, and display and voice features that are
    all included in the cost of computer controls.
  • Other factors that increase costs are auto lift
    features
  • Increased insulation is definitely an energy
    improvement feature along with shorter cook
    times, and higher production rates (Energy Star).
  • Because there are so many factors that contribute
    to pricing it is useful to concentrate on like
    products from like manufacturers.

10
Fryer Incremental Costs
  • If we looked at the Fry Master list of products
    well find some like items that we can compare
  • Factors that increase energy efficiency in fryers
    include Frypot insulation, low-watt density
    elements, modulating power controls
  • According to Fry Master, the TC units (Tier II)
    have computer controls, as opposed to just solid
    state controls, that as a part of their function
    will modulate the heating elements to improve
    demand control. The Tier II units will start out
    with less power. They go through a subroutine to
    slowly heat the oil to save energy. These
    aspects, according to Fry Master, contribute to
    the increase in cooking energy efficiency. The TC
    (Tier II) units also have insulated fry pots
    while the standard units (Tier I) do not. Both
    Tier I and Tier II units are equipped with low
    watt density heating elements
  • Solid state controls are an improvement over
    mechanical controls

11
Steamers
  • Applying the selection process yielded the
    following distribution for Steamers
  • For the 4-pan units, there is only one unit on
    the Energy Star list and so we can either
    disregard the 4-pan category entirely or use
    non-Energy Star units as the Tier I

12
Steamers Incremental Costs
  • For 3-pan Steamers we compared Market Forge units
    because Market Forge has a unit on Tier I and
    Tier II and found that the incremental cost
    between the Tier I and Tier II units are
    approximately 132. The difference being that the
    Tier II unit has a fully insulated cooking
    compartment while the Tier I unit does not.
  • For 5-pan Steamers, we did not have similar
    manufacturers with like products to compare
    pricing. We compared the Blodgett SBF-5 (Tier II)
    against the Vulcan Hart VPX5 (Tier I) because
    these two are very comparable units and the
    incremental cost was approximately 215.
    According to the cutsheets there was very little
    difference in the options except the fact that
    the IER for the Tier I unit was over twice the
    IER of the Tier II unit (550w vs. 220w). This can
    be reasonably attributed to both better
    insulation and possibly the controls during
    idling periods. Both units had the same cooking
    efficiency (68).
  • For 6-pan Steamers, if we compared Accutemp which
    have units on both Tier II and Tier I then the
    incremental cost is 800.00. The Tier II unit is
    a higher power unit that allows for faster
    startup and cook time (17 kW versus 6 kW).
    However, to have this incremental cost more
    inline with the 3-pan and 5-pan we interpolated
    the incremental costs using the 3-pan and 5-pan
    pricing and are proposing 209 as the incremental
    cost for the 6-pan units.

13
HFHC
  • HFHC are already divided into Tier I and Tier II
    based on the IER only. Up to 20 watts/ft³
    qualifies for Tier II and up to 40 watts/ft³
    qualifies for Tier I.
  • We chose to divide the population into half,
    three-quarters and full sizes with the following
    requirements
  • Half up to 12ft³
  • Three-quarters 12ft³ to 20ft³
  • Full 20ft³ and above
  • Then the distribution would be as follows

14
HFHC Incremental Costs
  • HFHC increase in efficiencies can come from
    better insulation, magnetic door gaskets, auto
    door closures and Dutch doors.
  • For HFHC cabinets, we averaged the pricing of
    each categories from Tier II and compared them to
    costs from Tier I and we get the following
    incremental costs
  • The Incremental Cost for the Half-size HFHC
    (10) 788.00
  • We looked at a Cambro CMBH (Tier II) and a Hatco
    FSHC (Tier I). Both units are insulated but the
    insulation on the Tier II unit may be better than
    the Tier I. Also, the energy draw for the Tier I
    unit was just simply larger (rated 14.1 amps
    versus 9.1).
  • The Incremental Cost for the Three-quarter-size
    HFHC (4) 710.00
  • We looked at a Cambro CMBH (Tier II) and a Henny
    Penny HHC-900 (Tier I). Both units are well
    insulated, have magnetic door gaskets, and Dutch
    doors. However, the energy draw for the Tier I
    unit was just simply larger (rated 17 amps versus
    13.7).
  • The Incremental Cost for the Full-size HFHC
    (10) 1505.00
  • For the Full-size units we looked at two
    InterMetro units that are roughly the same size,
    C569L (Tier II) and the C539 (Tier I). Both units
    were equipped with Dutch doors but only the Tier
    II unit had insulated doors. This could explain
    the difference in the IER of 14.8 versus an IER
    of 33.1.

15
Calculator
  • Modified ASTM Calculation (Two-Mode Model, based
    on Heavy Cooking Load, Idle Energy Rate, and
    Preheat Energy.
  • This was done due to current high efficiency
    parameters which was narrowed down to idle energy
    and cooking energy. If we want to include
    additional parameters such as light load cooking
    energy we will need to develop another Tier I and
    Tier II capacity rating and efficiency rating.
  • This information is very difficult to obtain.
    Only selected units energy efficiency is given
    on FSTC website.
  • Hours of Operation based on ADL and Steamer
    Report

16
Hours of Operation
  • Hours of Operation based on ADL Report for
    Steamers and Fryers and compared to other
    programs.
  • Hours of Operation for HFHC is basically a
    conservative number when compared to other
    programs.
  • 93 of Market between Restaurants (Fast Food/
    Dine-In), Lodging, and Retail. Feel comfortable
    using a deemed value.

17
Calculator (Hours of Operation)
18
Sensitivity Analysis
  • HFHC
  • Hours of Operation (Conservative at 12 hrs/day
    instead of 15)
  • Size of Units (Based on other models may want to
    include larger units)

19
Sensitivity Analysis
  • Fryers
  • Hours of Operation (Conservative at 10 hrs/day
    instead of 12)
  • Utilization Factor (15 instead of 20)
  • Conservative lbs of Food Cooked
  • Found that Light vs. Heavy Load Cooking doesnt
    really vary savings since the efficiency curve is
    relatively flat until very low loads lt10

20
Sensitivity Analysis
  • Steamers
  • Hours of Operation (Conservative at 7.5 hrs/day
    instead of 12)
  • Utilization Factor (20)
  • Conservative lbs of Food Cooked
  • Found that Light Load increases energy
    consumption due to lower efficiencies.
  • Found that other product (frozen peas) increases
    cooking efficiciency and increases cooking time.
    (Red Potato consumes more energy)

21
Savings
22
Discussion
  • Open Items.