LR6 LevelMASTER Pump Controller - PowerPoint PPT Presentation

1 / 20
About This Presentation
Title:

LR6 LevelMASTER Pump Controller

Description:

Suitable for use with any probe set. PROBE INPUTS ... Domestic Cellar. Stormwater Pit. Septic Tank. Sewer Pit. Overflow pit. LR6. 2 Pump with MultiTrode ... – PowerPoint PPT presentation

Number of Views:185
Avg rating:3.0/5.0
Slides: 21
Provided by: brad195
Category:

less

Transcript and Presenter's Notes

Title: LR6 LevelMASTER Pump Controller


1
LR6 LevelMASTERPump Controller
Techsys Corporation
2
APPLICATIONS
Tank Filling or Sum Applications
Suitable for use with any pump
3
LevelMASTER
  • Auto-Off-Manual Switch for two pumps
  • Run lights
  • Flashing Beacon
  • Inner door construction
  • Main switch behind outer door
  • Vandal Proof
  • IP65 Construction
  • Up to 1000kW standard

4
LR6
Output Relays
Input/Output Indicators
Telemetry Output terminals
Delay Timers
Sensitivity Adjustment
Float/Probe Inputs
Power Supply
5
SENSOR TYPES
  • PROBES
  • PROBES
  • NO/NC Probes
  • NO Probes

6
Power Supply
  • LR6 can be powered by multiple voltages
  • 240VAC
  • 12-25VAC
  • 15-35VDC

7
STARTING OPTIONS
  • DOL
  • Star - Delta
  • Soft Start
  • All Options Are Menu Selectable

8
OPERATION MODES
  • Tank Filling or Empting
  • Floats or Probes

Suitable for use with any probe set
9
PROBE INPUTS
Connection to EARTH possible if the tank is
conductive and connected to earth
?
10
SENSITIVITY ADJUSTMENT
Sensitivity adjustment for various liquids and
for switches that carry a resistance when open
For use with different liquids or cable run
lengths
11
DELAY TIMERS
Sensitivity adjustment for various liquids and
for switches that carry a resistance when open
Cut Out Delay
Cut In Delay
12
MULTITRODE COMPATIBLE
13
TELEMETRY
  • 4 x Voltage Free Outputs for telemetry
  • Any Alarm
  • Pump 1 Run
  • Pump 2 Run
  • Any Pump Run

14
INDIVIDUAL PUMP PROTECTION
  • Temperature sensor
  • Moisture Sensor
  • Under current relay
  • Circuit breaker trip relay
  • Wiring fault
  • Thermal overload
  • Individual Level switch
  • Thermistor relay
  • Flow switch

15
Single Phase
  • Up to 0.55kW single phase without Contactors

16
Single Float Operation
  • Single Float Operation

17
LR6
1 Pump with Probes
  • APPLICATIONS
  • Domestic Cellar
  • Stormwater Pit
  • Septic Tank
  • Sewer Pit
  • Overflow pit

18
LR6
2 Pump with MultiTrode
  • APPLICATIONS
  • Stormwater Pit
  • Sewer Pit
  • Overflow pit
  • Flood mitigation

19
LR6
2 Pump with Probes
  • APPLICATIONS
  • Stormwater Pit
  • Sewer Pit
  • Overflow pit
  • Flood mitigation

20
LR6
2 Pump Probe Tank Filling
  • APPLICATIONS
  • Water Supply
  • Multi story building
  • Reservoir supply
  • Mining Sites
Write a Comment
User Comments (0)
About PowerShow.com