SSI Binary Gradient Pump
  • Modular Simplicity

2
Ideal Gradient Characteristics
  • Modular design
  • Small foot print
  • Easy Maintenance
  • Compatible with stand alone control Data
    systems
  • 1ml to 5ml/min flow range with 1 resolution

3
Integrated Binary Gradient Pump
  • Small footprint
  • Integrates fluidics
  • Simple control
  • Low dead volume
  • High precision

4
Easy Maintenance
  • Modular design
  • Simple seal changes
  • Self flush is standard
  • Pumps are on pull out drawers
  • Each pump is independently serviceable

5
Fluid Path Fully Accessible
  • Easy Set up
  • Connect inlet lines
  • Connect line to Injector
  • Prime pump
  • 200ml Delay
  • Ez Prime in head PPV

6
Simple Front Panel Control
  • Can select and set
  • Flow
  • Max pressure limit
  • Low pressure limit
  • Allows monitoring
  • Pressure
  • Flow
  • Start or stop the pump

7
EZ Prime
  • Allows each head to be primed independently
  • Can prime head while other pump is running

8
High Performance
  • Dead volume is minimized
  • 0.001ml/min flow resolution
  • Out gassing effects minimized since mixing is on
    high pressure side of pump
  • Precise digital control of each solvents flow
  • Use data system interface for control or keypad
    controller

9
Low Delay Volume
Flow 0.5ml/min step at 3.0 min
200ml Delay
10
2 Gradient Steps at 0-10
520
500
480
Millivolts
460
35.0
40.0
45.0
50.0
55.0
Minutes
11
Fast Gradients at 3 mL/min
180
135
90
Millivolts
45
0
0.00
0.95
1.90
2.85
3.80
4.75
5.70
6.65
7.60
8.55
Minutes
100A for 2 minutes 0-100B in 1 min, 3 min
12
Linear and Step Binary Gradient Profile, 250
mL/min Two Runs Superimposed
100A for 2 min 0-100B over 25 min. Gradient
Accuracy was determined to be 1 absolute (of set
value)
13
Easy System Configuration
  • Add a detector
  • Choose a manual injection valve or Autosampler
  • Choose a column
  • Choose your data collection system
  • Begin

14
Wide Variety of Controllable Detectors
  • Fluorescence
  • UV/Vis
  • Single Channel
  • Multi Channel
  • Diode Array
  • Conductivity
  • Evaporative Light Scattering

15
Works With All Analog Detectors
  • Use EZ Chrom SI with 35900E A to D box
  • Use a keypad controller and a strip chart recorder

16
Application Specific Systems
  • Amino Acid Systems
  • Carbamate Systems
  • Clinical assay systems
  • Genetic Variant system
  • Aflatoxin System
  • Glyphosate system