Title: Dr. Mustafa Fatih ABASIYANIK
1Dr. Mustafa Fatih ABASIYANIK
- Biology Department
- 212 8663300 / 2020
- mfatih_at_fatih.edu.tr
2Education
- PhD, Gebze Institute of Technology,
Chemisty-2004, Kocaeli-Turkey - MS, FFatih University, Institute of Science,
Biology-2000, Istanbul, Turkey - BS, Ankara University, Faculty of Agriculture,
Zootechnics-1991, Ankara-Turkey
3My Projects
- Hemadiyaliz üniteleri diyalizatlarinda üre
miktarinin sürekli tayininde yeni biyosensör
modellemesi, DPT-, Dec 2006-Dec 2009, Ana
Yönetici Amount 504.000 YTL - Mide Kanseri, Peptik Ülser ve Gastritli Türk
Hastalardan Elde Edilen Helicobacter Pylori
Izolatlari cagA Genlerinin Moleküler
Tiplendirilmesi, DPT-, Dec 2006-Dec 2008,
Yardimci Yönetici Amount 201.000 YTL - On the origin of food The species identification
of meat products by modern DNA techniques,
Üniversite Arastirma Proje Fonu-, Oct 2006-Oct
2007, Ana Yönetici Amount 5200YTL - Oksidatif Stresin Mide Kanserindeki Rolü,
TUBITAK-, May 2006-May 2009, Yardimci Yönetici
Amount 227400YTL - Polikatyonik Grup Içeren Yeni Makrosiklik
Bilesiklerin Sentezi, Antibakteriyel
Özelliklerinin Analizi ve Biyolojik
Makromoleküllerle (DNA ve Protein)
Etkilesimlerinin Spektroskopik Ve Moleküler
Biyol, TUBITAK-, Feb 2006-Feb 2008, Yardimci
Yönetici Amount 100000YTL
4A novel Biosensor Modelling to screen urea
concentraion in hemadializing units
- Supported by DPT (359000YTL), Fatih University
and Institute of Gebze Technology - Start Dec 2006
- End Dec 2009
- Budget 504.000 YTL
5A novel Biosensor Modelling to screen urea
concentraion in hemadializing units
- Sensor A device that responds to a physical
stimulus (heat, light, sound, pressure, motion,
flow, and so on), and produces a corresponding
electrical signal.
6A novel Biosensor Modelling to screen urea
concentraion in hemadializing units
- Biosensor A device that uses a biological
element, such as an immobilized enzyme or cell,
as a sensor.
Substrate that is not easy to detect
enzyme
Detector Signaling when product touches
7A novel Biosensor Modelling to screen urea
concentraion in hemadializing units
- Example
- Substrate is not detected by any detector
- Enzyme catalyzes it
- Products can be detected easly
- Detector can detect them easly
- Estimate the amount of substrate
8A novel Biosensor Modelling to screen urea
concentraion in hemadializing units
- In our study, We desing a new biosensor to screen
urea concentration in dialysate solutins - Urea?not easy to detect
- Ammonia ? easy to detect
- Urease?immobilized enzyme to degrade it.
9(No Transcript)
10(No Transcript)
11(No Transcript)