Title: Joachim Frank
1Topic 3
2Generation of initial models, and fitting methods
- Initial models usually generated by hand, using O
as stereo modeling environment - Fitting methods
- A) single component rigid-body search using
locally normalized CC - B) multiple component flexible fitting
- 1) real-space refinement
- 2) NMFF (normal mode-based flexible fitting)
- 3) (when applicable) MD simulations with CC
against observed density map
J. Frank
3Example NMFF of protein-conducting channel
SecYEG channel bound to the translating
ribosome One model (front to front arrangement
of SecYEG heterotrimers) explains densities for
both inactive and active channels. Application
of NMFF (normal mode-based flexible fitting).
(see next slide)
J. Frank
Mitra et al., Nature, in press
4J. Frank
Mitra et al., Nature, in press
5Quality of fitted model
- Subjective criteria
- (i) the extent to which the model explains all
observed density is any density left
unexplained? - (ii) do any parts of the atomic model stick
out of the observed density? - (iii) for unreconciled multi-component docking
are different parts of the model in steric
conflict? Can the conflict be removed by
postulating conformational changes? - Objective/quantitative criteria
- Real-space refinement and NMFF return measures
for goodness of fit, from which the final
quality can be gauged - Correlation coefficient, R-factor, and Error
Residual (see examples in next slide)
J. Frank
6Goodness of fit by real-space refinement, as a
function of the number of pieces used In the
flexible fitting of the ribosome.
Goodness of fit criteria, and their sensitivity
to shift of the model away from the correct
position.
J. Frank
7Validation requirements
- 1) Reproducibility of the fitting Apply fitting
procedure to two independent (not halfset)
reconstructions, and compare the results using
rmsd. - 2) Reproducibility of conformational changes
deduced When real-space refinement is used on
two density maps A and B, to obtain two models
from which conformational changes are to be
deduced, then we need a control reconstruction,
A1, to which the same procedure is applied. - Rmsd between the relevant components of the
two structural models should be significantly
larger (factor of 3) than the rmsd between A and
A1.
J. Frank
8Archiving of fitted models
- Internal deposition (Archive Database)
- Public deposition in the pdb, in conjunction with
publications - We try to deposit the cryo-EM maps simultaneously
in the 3DEM data base. (Ribosome complexes
deposited by our group constitute the largest
portion of the existing 3DEM data base.)
J. Frank