Title: Punctal plugs for post-LASIK dry eye


1
Punctal plugs for post-LASIK dry eye
  • Ikuko Toda1
  • Kazuo Tsubota2

1Minamiaoyama Eye Clinic, Tokyo Japan 2Keio
University, School of Medicine, Tokyo, Japan
Finantial interest none
2
Purpose
To evaluate the efficacy of punctal plugs for
patients with post-LASIK dry eye.
3
Patients
  • 35 eyes in 19 patients who underwent LASIK.
  • Fulfilled the Japanese dry eye criteria at 1
    month postoperatively.
  • Plug group (20 eyes of 10 patients)
    Control group (15 eyes in 9 patients)
  • Punctal plugs were inserted into superior and
    inferior puncta in the plug group.
  • An artificial tear (0.3 hyaluronic acid, 5 times
    a day) was prescribed for both groups.

4
Methods
  • Uncorrected and best corrected visual acuity
    (UCVA and BCVA)
  • Refraction
  • Visual acuity after 0 and 10 seconds of eye
    opening (FVA-0 and FVA-10functional visual
    acuity)
  • SRI after 0 and 10 seconds eye of opening (SRI-0
    and SRI-10)
  • Corneal sensitivity
  • Schirmer test
  • Fluorescein staining
  • Tear break-up time (TBUT)
  • Dry eye symptoms
  1. Above factors were compared between the groups at
    1 month and 3 months postoperatively.
  2. The change of these data from 1 to 3 months were
    compared between the groups.

5
UCVA and FVA
Before plug insertion
N0.029
0 sec (FVA-0)
10 sec (FVA-10)
N0.021
plug
control
After plug insertion
0 sec (FVA-0)
10 sec (FVA-10)
6
SRI
N0.022
After plug insertion
Before plug insertion
0 sec (SRI-0)
10 sec (SRI-10)
0 sec (SRI-0)
10 sec (SRI-10)
plug
control
7
Corneal sensitivity
NNS
8
Tear function
Schirmer test
TBUT
N0.008
NNS
9
Fluorecsein staining
N0.020
10
Symptoms
Dryness
N0.020
N0.008
Foreign body sensation
11
Before plug insertion
After plug insertion
FVA-0 (LogMAR) -0.10
FVA-10 0.20
Decreased BCVA (line) -3
FVA-0 (LogMAR) -0.10
FVA-10 -0.10
Decreased BCVA (line) -1
12
Conclusion
  • Our results suggest that punctal occlusion for
    both puncta is effective for patients with
    post-LASIK dry eye, that can not be controlled
    only by artificial tears.
  • Punctal plugs are beneficial for these patients
    by improving not only dry eye symptoms and tear
    function, but also quality of vision, such as
    functional visual acuity.