ArchWeigh HP Belt Scale - PowerPoint PPT Presentation

1 / 14
About This Presentation
Title:

ArchWeigh HP Belt Scale

Description:

The only Load Cell patent for an 'in-motion weighing system' since 1970. ... Filters and Password Protection Keep Your System Safe & Secure. Click to Advance ... – PowerPoint PPT presentation

Number of Views:239
Avg rating:3.0/5.0
Slides: 15
Provided by: jayc9
Category:

less

Transcript and Presenter's Notes

Title: ArchWeigh HP Belt Scale


1
ArchWeigh HP Belt Scale
Click to Advance
Internal Speed Sensor
Direct Line Supply
The Most Technologically Advanced In-Motion Scale.
2
ArchWeigh Digital Belt Scale
Click to Advance
The ArchWeigh Digital Belt Scale will actually
make you money, from the day it is installed, in
several areas The ArchWeigh Belt Scale does not
drift out of calibration, as all other belt
scales do. The only Load Cell patent for an
"in-motion weighing system" since 1970. That
means all other belt scales are utilizing
antiquated, 30 year old technology.
  • 100 REPEATABLE ACCURACY.
  • Guaranteed to never drift No re-calibration
    needed
  • Dual HP Scales .25 Single HP Scale .5 SC
    Scale 1-2 of
  • Actual Tonnage Guaranteed - ALWAYS
  • EASY INSTALLATION
  • Simple Push-Button Calibration Operation
  • Eliminates Scale Maintenance Costly Scale
    Techs
  • Buying, Blending, Selling becomes Easily
    More Profitable

3
Click to Advance
To be accurate, any in-motion weighing system
must be able to compensate for the radial motion
of the idler and the movement of the material
itself. Constant compensation for radial motion
is necessary, otherwise this force will be
interpreted as additional weight.
The ArchWeigh Electronic Digital HP Belt Scale is
the solution to accurate, affordable, in- motion
weighing. As opposed to compensating for the
external force imposed on scales, by natural
conveyor variances, the ArchWeigh scale
accurately measures these forces and eliminates
them automatically from the material weight
measurement. The result is accurate weight
measurement without costly scale Tech's or
re-calibrating production stops. ArchWeighs
Patented Dual Ended Load Cells are the only loads
cells designed specifically for use on conveyor
belt scales since 1970.
4
Click to Advance
The ArchWeigh Integrators have patented State
of the Art Features, Functions, Options That
no other can offer.
  • Easy three-step calibration without test chains.
  • User-friendly three-button design reduces
    training time and minimizes the potential for
    errors.
  • Two built-in totalizers one totalizer can be
    reset to tailor information to your needs.
  • Data can be relayed to your PC or PLC, allowing
    you to monitor and control your scales from a
    remote control room /or any area vehicle.
  • Reduces the need for scale technicians. The
    integrator is so simple to use, it can be
    maintained by your staff.
  • Both the 1000 and 2000 Integrators have the same
    capabilities. However, the 2000 is able to run
    multiple scales at the same time thus eliminating
    the need/cost of one Integrator per scale.
  • Punch Tickets per Shift or per Driver per Load
  • Controls -Monitors-Charts Your Flow Rates, Speeds
    Totals
  • Print your Production per load/shift/day/week/mon
    th/year
  • Maintains Multiple Running Totals
  • Self Diagnostic Calibration Updates 15x per
    Second
  • LCD Monitors Controls up to 6 Scales _at_ Once
  • Monitor Display Production anywhere in the
    world.

5
Click to Advance
6
Click to Advance
The Weight Integrator processes and displays the
Total Weight, Rate of Flow, Belt Speed, and other
related information on a Liquid Crystal Display
screen (LCD). Providing re-settable and
customized totalizers, retrieved data is relayed
to your PC or your PLC, allowing production
monitoring and recording from literally anywhere
in the world. Simple User Friendly Design
Eliminates Costly Scale Maintenance and Scale
Techs. Justifying its own cost. Dual Digital
Filters and Password Protection Keep Your System
Safe Secure.

7
Click to Advance
ArchWeigh 1000 Weight Integrator Specifications
Dimensions A. 20" (508
mm) B. 16" (406.4 mm)
C. 8" (203.2 mm)
  • Enclosure
  • Dimensions 20"(H) x 16"(W) x 8"(D)
  • Protection NEMA 12
  • Construction Steel
  • Processor
  • Resolution 1500,000
  • Updates 60/second
  • Filter 3 Pole digital
  • Converter 20-Bit analog to digital
  • Port RS422 remote host interface
  • Output Pulse output, field definable
  • Display
  • LCD 20 character (.385 inch) 4 row
    alphanumeric backlit
  • Indication Static weight and rate
  • Units Any unit of measurement
  • Options
  • Outputs 4-20 mA, 0-20 mA,
  • 0-5V, 0-10V, digital
  • Displays Large display, remote display, charter
    recorder, long distance display
  • Control Set point control
  • Power
  • Voltage 110 or 220 VAC
  • Power 1 amp

Protection Internal fuse
8

Click to Advance
9

Click to Advance
  • Dual ArchWeigh HP Belt Scales achieve maintain
    .25 Accuracy
  • ArchWeigh HP Belt Scale achieves maintains .5
    Accuracy
  • ArchWeigh SC Belt Scale achieves maintains 1
    to 2 Accuracy
  • Call 800-940-4044 or Fax 800-845-6787

10
ArchWeigh HP Scale Install
Click to Advance
Click to Advance
11
Click to Advance
ArchWeigh HP Scale In Action
Click to Advance
12
Dimensions of StandardHP Scale Integrator
Click to Advance
  1. Load Cells
  2. Speed Sensor
  3. Scale Duty Idler
  4. Predetermined Trough Angle Cema Rating
  5. Scale Base/Structure Mounting

13
Click to Advance
Features and Options for any model scale and
Integrator can be added to your order Customize
Your Conveyor Scale(s)
Outputs 4-20 mA, 0-20 mA, 0-5V, 0-10V, Digital-
PLC Interface Displays Large Display, Remote
Display, Wireless Display Chart Recorder, Ticket
Printers (per load/batch or any time/weight
measurement) Long Distance Displays Terminals
Full Functions Remote Terminal, PC Interface
Software Package.
Controls Batch Control Capabilities Port
RS422 Remote Host Interface for PC Remote
Controls and display for vehicle and remote
monitoring and Remote controlling feeds,
conveyors, etc
14
Click to Advance
The ArchWeigh Digital Belt Scale
  • Dual ArchWeigh HP Belt Scales achieve maintain
    .25 Accuracy
  • ArchWeigh HP Belt Scale achieves maintains .5
    Accuracy
  • ArchWeigh SC Belt Scale achieves maintains 1
    to 2 Accuracy
  • Call 800-940-4044 or Fax 800-845-6787

Guaranteed
Internal Speed Sensor
Write a Comment
User Comments (0)
About PowerShow.com