Title: Renata%20T.%20Kashiwabuchi%20MD,%20Carlos%20G.%20Arce%20MD,
1Galilei System Combining Double Scheimpflug and
Placido Technology
- Renata T. Kashiwabuchi MD, Carlos G. Arce MD,
- Mauro Campos MD, Paulo Schor MD
Ocular Bioengineering and Refractive Surgery
Sectors, Institute of Vision Department of
Ophthalmology, Paulista School of
Medicine Federal University of São Paulo, Brazil
Financial Disclosure Authors do not have
financial or commercial interest in mentioned
equipments Dr Arce is Consultant Territory
Manager for Latin America, Vista Optics Limited,
Widnes, UK RD Consultant, Ziemer Group AG,
Port, Switzerland Speaker, Bausch Lomb do
Brasil, and Diretor Geral, R.E.I. Comércio
Ltda., Campinas, SP Dr. Campos is Consultant of
Alcon Laboratorios do Brasil
2- INTRODUCTION
- Galilei is a multifunctional system that
integrates the two more valuable technologies
presently - available to study the cornea Placido
reflection of rings and dual Scheimpflug imaging. - Combined system displays maps with 14,400 point
values of real topography, elevation and
pachymetry calculated from 122,000 data points
assessed from the cornea and the anterior segment
of the eye
- Features
- Two Scheimpflug cameras
- Double Placido calculation
- Digital top view camera
- Iris recognition device
- Cyclotorsion correction
- Anterior surface topography
- Posterior surface topography
- Corneal Pachymetry
- Anterior chamber pachymetry
- Corneal 3-D densitometry
- Lens 3-D densitometry
- Biometry of anterior segment
- Zernike WF analysis of cornea
- Differential maps
- Zoom of all Scheimpflug images
- Applications
- Keratoconus diagnosis
- Preop/postoperative exams
- Follow up of corneal diseases
- Topographic biomechanical signs
- Cataract diagnosis
- Biometry of anterior segment
- Digital goniometry
- Eye photography
- Photographic records
- Corneal power for IOL calculation
- Postop of multi-focal toric IOLs
- WF study of the cornea
3Apparent slit images
Light slits
Left camera
Right camera
Exams are centered to Placido reflection and
to Scheimpflug images
12
9
12
3
9
6
6
3
Double Placido analysis of anterior surface
Iris recognition and cyclo-torsion correction
devices localize the real position of each slit
4Real Placido and Scheimpflug Topography
4xMap of FFKC with KPI 14 Showing anterior and
posterior axial curvature and digital goniometry
4xMap of RK showing both surfaces
Refractive report of post myopic LASIK
Corneal total power For IOL calculation after
refractive surgery ?
4xMap of KC with anterior surface steeper than
posterior
Keratoconus Report
4xMap of KC showing both surfaces
Astigmatism of 6.7 D with KPI 0
Astigmatism of 4.16 D with KPI 17
5Digital BW and color 3-D corneal, lens, and
anterior chamber densitometry, imaging and
biometry
Top view eye photo and metrics
Clinical Applications
Dislocated IOL Multi-focal IOL
position
DLK Evolution
3rd day post-LASIK
1st day after washing
7th day after washing
2nd day after washing
Scheimpflug images after Corneal Transplant