Title: Daikin Altherma HT


1
Daikin Altherma HT
2
Table of contents
1. Product concept
2. Product features
3. Applications
4. Product line-up
4. Nomenclature
5. Specifications
6. Summary
3
Product concept
Cascade system 2 refrigerant cycles with 2
inverter compressors
Leaving water temperatures possible up to 80C,
ambient temperature down to -20C
Heating capacities 11, 14 and 16kW (single and
three phase)
1
2
3
down to -20C
up to 80C
Indoor
Outdoor
4
Product concept 3 heat exchangers
Outdoor unit evaporator air R410A energy
exchange
1
First plate heat exchanger R410A R134a energy
transfer (indoor unit)
2
Second plate heat exchanger R134a H2O energy
exchange, allowing LWT up to 80C (indoor unit)
3
On thermodynamic efforts only, no electrical
heater
Symbolic graph
R134a
3
Second stage condense temperature
2
Intermediate condense temperature
R410A
1
5
Product concept target market
Typical supply temperature areas of different
heat generators
Standard Boiler
LT-Boiler
Condensing Boiler
Daikin Altherma Split Monobloc
(VLC)
Daikin Altherma
Daikin Altherma HT
20
30
40
50
60
70
80
90
Floor heating
TARGET MARKET
Fan convectors
LT radiators
HT radiators
6
Product concept target market
Leaving water temperatures possible up to 80C
which makes it the perfect solution in
combination with existing high temperature
radiators
Refurbishment market
Outdoor unit
Indoor unit (DHW tank included)
High temperature radiators and domestic hot water
Very efficient way to heat up the DHW, no
electrical heater required
7
Product concept target market
With a maximum TLWC of 80C, the Daikin Altherma
HT can cover the biggest part of the
refurbishment market
Cover more than 90 of the refurbishment demand
100
gt 90
Demand coverage of refurbishment market ()
Max TLWC (C)
60C
80C
90C
65C
25C
8
Table of contents
1. Product concept
2. Product features
3. Applications
4. Product line-up
4. Nomenclature
5. Specifications
6. Summary
9
Product features indoor unit
Easy installation thanks to the complete indoor
unit with DHW tank and hydraulic components
already included
DHW tank 200L or 260L
Hydrobox (small footprint)
10
Product features indoor unit
If necessary, the DHW tank can also be installed
next to the hydrobox
1580 mm
1335 mm
260L
200L
Option kit for standalone tank EKFMAHTA
includes 1) top plate 2) adaptors (to go
from quick couplers to screw connections) 3)
piping between the screw connections (max
distance between hydrobox and DHW
tank is 25cm, longer pipes are field supply)
11
Product features hydrobox
Heat exchanger R134a ? H2O
Air purge
Heat exchanger R410A ? R134a
Manometer
Expansion vessel (12L)
Pump (DC-inverter to maintain fixed ?T)
Compressor R134a
12
Product features hydrobox
3 way valve located in hydrobox (only with DHW
tank)
13
Product features PCB plate
Switchbox is located behind the front plate of
the hydrobox
14
Product features DHW tank
Product line-up DHW tank
200 L
260 L
DHW tank line-up 6 models
Standard
UK model
Special TBC
Option kit for UK EKUHWHTA
other material name than on Daikin Altherma
Split and Monobloc
15
Product features DHW tank
Main parts DHW tank
16
Product features DHW tank
Standard tank
Naked tank lay-out
Fully assembled (at factory)
Front panels detached
Top plate from Hydrobox or EKFMAHTA
17
Product features DHW tank
UK tank standard tank factory fitted Tp valve
Factory fitted Tp valve
18
Product features DHW tank
Option kit on UK tank EKUHWHTA
Pressure reducing valve
Expansion relief valve
7
lt500 mm
Tundish
Expansion vessel (18L)
gt300 mm
Tundish
7
H
C
4
8
7
7
6
19
Product features DHW tank
Special tank standard tank passivated
service opening
TBC
Passivated tank requirement for Danmark
Service hole requirement for Switzerland and
Germany
Cleaning opening of 120 mm at the lowest third
part of the tank
20
Product features DHW tank
Tank performance heat-up time (calculations)
Size of the coil length of 23m, surface area of
1,56m², internal coil volume of 7,5L
Calculation example ERSQ016AAV1 with EKHTS200
tank
Up to a DHW temperature of 70C, the part load
capacity of the heat pump can still be exchanged
to the DHW with the 1,56m² coil
21
Product features DHW tank
Tank performance heat losses
200 l 260 l
Total capacity (L) 201 258
Actual capacity (L) 193,5 250,5
Heat loss (kWh/24h) at dT 45C 1.2 1.5
Heat loss (W) at dT 45C 50 62,5
Max. temperature (C) 75 75
Total capacity internal volume of the tank (
effective water volume coil volume
Actual capacity effective water volume inside
the tank
22
Product features DHW tank
Tank performance heat-up time and reheat time
23
Product features DHW tank
Different possibilities to produce DHW
Reheat operation has always priority above space
heating
Disinfection operation has always priority above
space heating
  • Storage operation
  • automatic operation (night and/or day timer)
  • manual operation
  • Storage operation has priority above space
    heating, taking in account
  • min/max running timers
  • smart logic function

24
Product features DHW tank
Tank performance maximum volume of usable hot
water
25
Product features User interface
User interface is mounted separately from indoor
unit
User interface can be used as a modulating room
thermostat
Optimized efficiency due to feedback of room
temperature
Optimized changeover from DHW heating to space
heating
Option kit Remote user interface EKRUAHTA
The same controller as supplied with indoor unit
can be mounted parallel or on other location. If
2 controllers are installed, the installer needs
to select 1 master 1 slave.
Not possible to use both user interfaces as a
multi zone application (e.g. one in living room,
other one in the kitchen)
26
Product features Control possibilities
Weather dependent floating setpoint TLWC f(Ta)
1
Thermostat control user interface as room
thermostat or normal room thermostat
2
Thermostatic valve
3
2
ROOM 1 master room (eg living room)
ROOM 2
ROOM 3
Ta
T
Tl
thermostatic valve temperature control by liquid
or gas expansion
radiator valve
room thermostat
3
6 settings
1 2 3 4 5
Weather dependent floating setpoint
TLWC
20C
1
ON/OFF-valve manual control
27C
7C
temperature control
Ta
27
Product features Full H/P tariff
Equipment allows for connection to a benefit kWh
rate power supply
New on Daikin Altherma HT
Controllers are connected to a normal power
connection
When the benefit kWh rate power supply is
interrupted, the compressor will stop operating,
but there is no chance that the settings will be
lost during longer power shutdowns
28
Product features zone 2 and zone 3 model
Freeze protection for outdoor unit bottom plate
heater
  • A bottom plate heater will be standard in areas
    where low ambient temperatures can occur together
    with high humidity conditions (zone 2 model
    ERRQ), in other countries a bottom plate heater
    is available as an option (zone 3 model ERSQ).
  • To protect the outdoor unit against severe ice
    build-up on the air-cooled coil

New on Daikin Altherma HT
The bottom plate heater has no external
thermostat, but is controlled by the PCB of the
indoor unit
  • ON/OFF depending on
  • Hysteresis 3 lt Ta lt 5
  • Unit operation status

29
Product features zone 2 and zone 3 model
cold climate
Zone 2 model ERRQ Outdoor unit is equipped with
a Bottom plate heater
zone 2
Zone 2 3 gt 85 of the heating market
zone 3
Zone 3 model ERSQ Bottom plate heater as an
option
mild climate
Zone 2 countries Only access to zone 2 models
Zone 3 and 4 countries Access to both models
30
Table of contents
1. Product concept
2. Product features
3. Applications
4. Product line-up
4. Nomenclature
5. Specifications
6. Summary
31
Applications examples
Space heating DHW heating 1 RC in living room
  • No frequent start/stop of the unit and no big
    temperature fluctuations in the room
  • Smart logic functionality which controls the
    combined space heating and DHW demand

32
Applications examples
Space heating DHW heating 1 RC in living room,
1RC near the unit
The main remote controller (C1) is installed in
the living room and can access all settings
(master). The second remote controller (C2) can
not access schedule and parameter settings (slave)
33
Applications examples
Space heating DHW heating 1 external RT in
living room, 1RC near the unit
There is only room thermostat on/off control.
There is no smart logic functionality for space
heating, DHW operation is performed according to
the min/max timer operation
Daikin can not guarantee neither good operation
nor reliability of the system, if a non-Daikin
thermostat is used ( NO WARRANTY)
34
Applications examples
Multiple setpoint control
Space 0 Radiators Tsetpoint 65C
Space 1 Fan Coil Units Tsetpoint 45C
Space 2 Under Floor Heating Tsetpoint 35C
If there is a heat demand from space 0, the
leaving water temperature delivered by the Daikin
system is too high
A Temperature reducing device (TRD) is required
for space 1 and 2, to lower the water temperature

TRD
When TRDs are installed, the system can be
configured to use multiple water set point.
  • The TRDs are field supply
  • Control of the TRDs is not done by the heat
    pump system
  • Operation and configuration of the TRDs is the
    responsibility of the installer

Daikin only offers the possibility to have
multiple set points
35
Applications examples
Space heating DHW heating Radiators and UFH,
DHW tank parallel
  • 2 space heating setpoints
  • 1 DHW setpoint

no 3-way valve
The DHW tank is installed in parallel with the
TRDs. This allows operating the unit in space
heating and DHW heating simultaneously
36
Applications examples
Space heating DHW heating Radiators / FCU /
UFH, DHW tank in a separate circuit
  • 3 space heating setpoints
  • 1 DHW setpoint b-03

The DHW tank is installed in a separate circuit
of the TRDs. This configuration does not allow
simultaneous DHW heating and space heating
operation.
37
Applications examples
Space heating DHW heating space heating with
an auxiliary boiler (alternating operation)
  • Bivalent operation is only possible for space
    heating operation, not for DHW heating operation
  • An auxiliary contact decides whether either the
    Daikin unit or the boiler will operate (e.g.
    outdoor thermostat, electricity tariff contact,
    manually operated contact)

38
Table of contents
1. Product concept
2. Product features
3. Applications
4. Product line-up
4. Nomenclature
5. Specifications
6. Summary
39
Product line-up
Single Phase
Three Phase
Outdoor unit line-up 12 models
Zone 2
Zone 3
11kW
14kW
16kW
Single Phase
Three Phase
Indoor unit line-up 6 models
11kW
14kW
16kW
200 L
260 L
DHW tank line-up 6 models
Standard
UK model
Special TBC
40
Product line-up standard equipment
41
Product line-up optional equipment
Optional kits connected to the indoor unit
Demand PCB required to be able to connect room
thermostat or BUH kit and for multiple setpoint
control (see service presentation)
42
Product line-up Combination table
Combination table of outdoor and indoor unit
43
Product line-up optional equipment
Optional kits connected to the outdoor unit
If a bottom plate heater is installed
(EKBPHTH16A), than its not allowed to install
the drain plug kit
A bottom plate heater is standard, the drain plug
kit can not be installed
44
Product line-up optional equipment
Optional kits connected to the DHW tank
45
Table of contents
1. Product concept
2. Product features
3. Applications
4. Product line-up
4. Nomenclature
5. Specifications
6. Summary
46
Nomenclature Outdoor unit
E
R
S
011
A
A
V1
Q
Power supply code V1 1 / 220-240V / 50Hz Y1
3 / 380-415V / 50Hz
Minor model change
Major model change
Capacity index kW
Refrigerant code Q R410A
Temperature zone indication S Ambient zone 3 R
Ambient zone 2
R outdoor model
E European model
47
Nomenclature Indoor unit
E
K
HBR
011
A
A
V1
D
Power supply code V1 1 / 220-240V / 50Hz Y1
3 / 380-415V / 50Hz
Minor model change
Major model change
Capacity index kW
Refrigerant code D R134a
HBR hydrobox H/O HT
K indoor model
E European model
48
Nomenclature DHW tank
E
K
HT
200
S
(U)
A
A model change
Water volume 200 200 L tank 260 260 L tank
DHW tank type No letter standard tank U UK
tank P passivated service opening
S Stainless steel tank
HT high temperature tank
K indoor model
E European model
49
Table of contents
1. Product concept
2. Product features
3. Applications
4. Product line-up
4. Nomenclature
5. Specifications
6. Summary
50
Specifications Sound Data
011 model
014 model
016 model
Outdoor unit
Sound Pressure at 1m
52 dBA
53 dBA
55 dBA
69 dBA
71 dBA
Sound Power
68 dBA
Position for measuring the Sound Pressure level
of the outdoor unit
51
Specifications Sound Data
Indoor unit Sound Pressure level
Two different ways of measuring the Sound
Pressure level of the indoor unit
Sound Pressure level in front of the indoor unit
Maximum Sound Pressure level possible at the four
other microphones
52
Specifications Sound Data
Indoor unit Sound Pressure level
Low sound mode has three different steps, Sound
Pressure level of mode n2 and n3 is lower than
n1
53
Specifications Sound Data
011 model
014 model
016 model
Indoor unit
Sound Power
59 dBA
60 dBA
60 dBA
  • Measurement condition
  • Ta7/6C
  • Heating setpoint 70/80C
  • Maximum compressor frequency

54
Specifications Operation range space heating
Space heating
Shift value of 5C is possible via field setting
55
Specifications Operation range DHW heating
DHW heating
56
Specifications Capacity table
Conditions for Capacity table
57
Specifications Capacity table (nominal values)
58
Specifications Capacity table (peak values)
59
Specifications Capacity table (peak values)
60
Specifications Capacity table (peak values)
61
Specifications Capacity table (peak values)
62
Specifications Capacity table (peak values)
63
Specifications Capacity table (integrated
values)
64
Specifications Capacity table (integrated
values)
65
Specifications Capacity table (integrated
values)
66
Specifications COP Peak values LT and HT
COP values for 16kW model (3 phase) at Ta 7C)
Daikin Altherma LT Split and Daikin Altherma HT
Daikin Altherma LT excellent heat pump for Low
Temperature applications
Daikin Altherma HT excellent heat pump for High
Temperature applications
67
Specifications Dimensions
Indoor unit hydrobox DHW tank
Outdoor unit
68
Specifications Packing and shipping
4 EPS corners
Top is made of carton
The whole unit is foiled
Unit is fixed on palette
Front-packing of DHW tank
Back-packing of DHW tank
Back-packing of Hydrobox
69
Table of contents
1. Product concept
2. Product features
3. Applications
4. Product line-up
4. Nomenclature
5. Specifications
6. Summary
70
To summarize product features
Tlwc up to 80C gt refurbishment market, no
booster heater
Unit operates with guaranteed capacity down to -
20C
Newly designed casing in modern metallic color
Integrated design of hydrobox and DHW tank
All required hydraulic parts are included in
hydrobox
DC inverter pump to maintain fixed ?T
User interface can be used as a room thermostat
Full H/P tariff
Standard bottom plate heater on ERRQ, controlled
by indoor unit
Flat Peak capacity trend down to -7C for Tlwc
80C