Title: Complication in angioplasty
1Complication in angioplasty
- The case I dont want to have again
- MC Morice, Massy France
2 Syncope with chest pain 2 hours before admission
DR, m 60y
Cardiovascular risk-factors
- Smoking history
- Hypertension
- Diabetes mellitus
Cardiovascular history
- Ischemic stroke (1980, without neurological
sequel)
STEMI with persistent elevation ST inferior and
lateral
3ECG before PCI
- Inferior and Lateral ST segment elevation
- Syncope, no chest pain
- No clinical signs of shock
4Angiogram
OM1 50-70. Proximal RCA 100
5Primary Angioplasty RCA occlusion
Radial approach. AL1 6F
BHW wire EXPORT thrombectomy system
Result
6Angioplasty 2
Dilatation Maverick 2/12mm ballon (10 atm)
BHWBMW wires.
Result
7Angioplasty 3
Stent DRIVER 3.0/30 mm (10 atm)
Result
8Angioplasty 4
Intrastent x3 dilatation Mercury NC 3.0/10mm
ballon (max 30 atm)
Temporary pacemeker for third degree AV block
9Angioplasty 5
Stent MICRO DRIVER 2.5/18
Stent DRIVER 3/24
Stent MICRO DRIVER 2.25/24
IC Verapamil
10Final result
Unsuccessfull primary angioplasty RCA occlusion
Instable hemodynamic state Intra-aortic ballon
pumping
11After failed angioplasty
- Clinical signs of Cardiogenic shock requiring
- Tracheal intubation
- Inotropic support
- Intra-aortic ballon pumping
- Temporary pacemaker
- Echocardiography
- LVEF lt30, akinetic inferolateral segments of LV
- RV akinetic
12ECG post angioplasty
13After 2 days on ICU
Progressive multi-organ failure
- PCI Treatment of OM1
- Implantation of an Left ventricular assist
IMPELLA
14Final evolution
- Final evolution
- Slow recovery to a Stable hemodynamic state
- Echocardiography
- Improved LVEF 50 inferoapical akinesia
Hospital discharge 1 month after PCI
15ECG after PCI obtuse marginale
ECG before discharge
16Summary
- Clinical case IMPELLA in cardiogenic shock
- Primary angioplasty is not always succesful
despite the use of thrombectomy and stenting and
as in our case can result in clinical
deterioration - Intra-aortic ballon pumping is not very effective
in RV failure - The Impella device can be useful?