Title: Techniques for synaptic vesicle recycling
1Techniques for synaptic vesicle recycling
22. Imaging SynaptopHluorin
SynaptopHluorin
Miesenbock et al, Nature 1998
Sankaranarayanan et al, Biophys J 2000
3SynaptopHluorin reports synaptic vesicle
exocytosis
Sankaranarayanan Ryan, Nat Cell Biol 2000
42. Imaging SynaptopHluorin
Bafilomycin to separate exo/endocytosis
Mani et al, Neuron 2007
52. Imaging SynaptopHluorin
Transgenetic mice expressing SynaptopHluorin
Li et al, PNAS 2005
62. Imaging Synaptophysin-pHluorin
Granseth et al, Neuron 2006
7Full fusion and kiss-and-run
Harata et al, J Neurochem 2006
82. Imaging quantum dots
Detection of full fusion and kiss-and-run by
quantum dots
Zhang et al, Science 2009
92. Imaging quantum dots
Detection of full fusion and kiss-and-run by
quantum dots
Zhang et al, Science 2009
103. Electron microscopy
- Docked vesicles
- Endocytic vesicle biogenesis
Rettig Neher, Science 2002
113. Electron microscopy
Defects in synaptic vesicle endocytosis
Hayashi et al, PNAS 2008
12Chromaffin cells as the model system for vesicle
cycling
13Differences between neurons and chromaffin cells
Intracellular vesicle trafficking pathway
14Munc-18 is important for vesicle docking
Voets et al, Neuron 2003
15Chromaffin cells as the model system for vesicle
cycling
16Membrane conductance and capacitance
17Technique 1 capacitance measurements Time
domain technique
18Technique 1 capacitance measurementsSine-wave
technique
1 ?F/cm2
19Whole cell capacitance technique
20Ca2 photolysis
NP-EGTA
21Whole-cell capacitance technique and Ca2
photolysis
Rettig Neher, Science 2002
22(No Transcript)
23(No Transcript)
24Cell-attached capacitance to detect single
vesicle fusion
25Amperometry detects catecholamine release
from single vesicles by oxidization
Amperometry
Amperometrical current
Chromaffin cell
26Technique 2 amperometryAmperometry gives
information about the release process
Analysis of single spikes
kiss-and-run
full fusion
stand-alone foot
27Different isoform of synaptotagmin controls the
choice between full fusion and kiss-and-run
Wang et al, Nature 2003
28Patch amperometry a method combines amperometry
and cell-attached capacitance measurement
Simultaneous detections of fusion and
neurotransmitter release of same vesicle.
Albillos et al., Nature 1997
29The neurotransmitter release is limited by the
size of fusion pore
Gong et al, Nat Cell Biol 2007
30- Neuroendocrine chromaffin cells
- Whole-cell capacitance technique
- Cell-attached capacitance technique
- Amperometry
- Patch amperometry