Fluorescence Resonance Energy Transfer (FRET) - PowerPoint PPT Presentation

About This Presentation
Title:

Fluorescence Resonance Energy Transfer (FRET)

Description:

Fluorescence Resonance Energy Transfer (FRET) Xingwei Wang * * FRET based immunosensor From ref [1] * Principle Two fluorophores: Donor & acceptor In close proximity ... – PowerPoint PPT presentation

Number of Views:2765
Avg rating:3.0/5.0
Slides: 21
Provided by: wei8158
Learn more at: https://faculty.uml.edu
Category:

less

Transcript and Presenter's Notes

Title: Fluorescence Resonance Energy Transfer (FRET)


1
Fluorescence Resonance Energy Transfer (FRET)
  • Xingwei Wang

2
FRET based immunosensor
From ref 1
3
Principle
  • Two fluorophores Donor acceptor
  • In close proximity
  • the donor absorbs energy from the source
  • transfers the energy to the acceptor
  • the acceptor emits fluorescent energy
  • Distance dependent property
  • Detect conformational changes when antibodies
    combine with their respective antigens

4
Principle (2)
  • The fluorophores were conjugated to an
    antibody-Protein A complex
  • then immobilized to the distal end of an optical
    fiber.
  • Conformational changes
  • Investigate donor and acceptor fluorophore
    emission spectrum

5
Application I Monitor early markers of
myocardial infarction
  • 1.1 million cases of acute myocardial infarction
    (AMI) occur each year in the United States
  • Can be modified and inserted subcutaneously to
    provide early warning of an impending heart attack

6
Principle
  • Försters distance the distance where energy
    transfer from the donor to acceptor fluorophore
    is 50 (lt 100 A)
  • Close ?0 -gt ?2
  • Separated ?0 -gt ?1
  • Conformational Change

7
Performance
  • Detection limit 27nM
  • 600 µm diameter silica core optical fibers
  • Taper end
  • hydrofluoric acid for 2-4 hours
  • 12.0 mm of the cladding was removed
  • Evanescent wave reaches the sensing area of the
    cladding-stripped fiber tip
  • Exciting the donor fluorophores located within
    its penetrating depth

8
Emission Spectrum
From ref 1
9
Spectrum Methods
  • The donor fluorophore excitation light 540 nm
  • Peak 1 (P1), is the donor emission spectrum with
    maximum peak intensity at 570 nm.
  • Peak 2 (P2), is the acceptor emission spectrum
    with maximum peak intensity at 610 nm.
  • Rather than analyzing intensity of the emission
    curves
  • susceptible to instrumental baseline shifts
  • Using
  • the maximum area under each emission spectrum
  • The ratio of the maximum donor to acceptor area
    (P1/P2)

10
Results
  • A decrease in the P1/P2 ratio after antigen
    addition is indicative of energy transfer.

11
Problem - High STD
  • Different tapering angles - different amounts of
    photons being captured back
  • Different exposed surface areas - different
    antibody-Protein immobilized different signal
    strength

12
Applications II Food safety Detection of
Listeria
  • U.S. each year
  • 33 million cases of foodborne diseases
  • more than 5 billion dollars for treatment
  • about 9,000 deaths
  • Listeria - one of the main organisms causing the
    outbreaks of foodborne illnesses
  • Rapid, accurate methods for detecting pathogens
    in food processing facilities are needed.

13
Advantage
  • Detect only viable analytes
  • Reduce false positives
  • Listeria antigen detection limits 2.0µg/ml

14
Schematic of the FRET Immunosensor
15
Spectrum
  • I(h 570 nm to 575 nm) the average fluorescence
    intensity of the donor fluorophore
  • I(h 608 nm to 613 nm) the average fluorescence
    intensity of the acceptor

16
Measuremet
With no antigen present (baseline)
With specific or nonspecific antigen present
Ratio used to determine change
17
Detection limit 2.0 µg/ml
18
Advantages
  • Portable
  • On-site analysis of samples
  • Reduce the large economical burden by food
    products recalls and medical treatments

19
FRET video
  • http//www.youtube.com/watch?vpMH8zcWa7WA

20
References
  • Development of a FRET based fiber-optic biosensor
    for early detection of myocardial
    infarctionPierce, M.E. Grant, S.A.Engineering
    in Medicine and Biology Society, 2004. EMBC 2004.
    Conference Proceedings. 26th Annual International
    Conference of theVolume 1,  2004 Page(s)2098 -
    2101 Vol.3
  • Development of a novel FRET immunosensor for
    detection of listeriaKo, S. Grant,
    S.A.Sensors, 2003. Proceedings of IEEEVolume
    1,  22-24 Oct. 2003 Page(s)288 - 292 Vol.
Write a Comment
User Comments (0)
About PowerShow.com