KX-TDA200/100 System - PowerPoint PPT Presentation

1 / 67
About This Presentation
Title:

KX-TDA200/100 System

Description:

KX-TDA200/100 System (Ver.1.1) Enhanced Items Panasonic Communications Co., Ltd. Network Business Company Edition 1.3 07 Jul., 2004 General System Highlight New ... – PowerPoint PPT presentation

Number of Views:959
Avg rating:3.0/5.0
Slides: 68
Provided by: panasuppo
Category:

less

Transcript and Presenter's Notes

Title: KX-TDA200/100 System


1
KX-TDA200/100 System
  • (Ver.1.1)

Enhanced Items
  • Panasonic Communications Co., Ltd.
  • Network Business Company
  • Edition 1.3 07 Jul., 2004

2
General
  • System Highlight
  • New Features
  • Condition of New Features
  • Software Compatibility

3
System Highlight
V1.0
Networking(QSIG), Call Center, VoIP
Gateway, CTI (CSTA/TAPI), T76xx Line Up,
Wireless System
V1.1
- Digital XDP Double Extension Capacity by MEC
- New VoIP Gateway Card (Panasonic
proprietary) - New CS to DPT Port - And other new
features
4
New Features
BRI4, IPGW4E, CSIF4, 2chCS, MEC DXDP Double
Extension Capacity New IPGW Card 2chCS Broadcastin
g Dialing Plan Ext. CLIP sending on Emergency
Call Short Cut Access to System Speed
Dial Modified DDI Number is displayed on
LCD Improved DSS LED Flash / Call Pick up Disable
Hold Recall Disable re-count Ext-CO Duration
Limitation by Hold Retrieve ISDN-3party
Conference DTMF Tone through a Conference from
PT Intercept Timer for each time
mode(Day/Night/Lunch/Break) SMDR RC/AN
information output Paging to other paging
group COS Name is programmable CS port Name is
programmable Ext. CLIP Automatic
Generating DDI/DID Name Automatic
Generating Wireless XDP Programming from
PC Logical Check PS Hand-Over during Conference
Call Walking Extension from Fault Extension
Hardware Function Improvement

Highlight Making calls Receiving
calls Hold/FWD/TR Conference Timer Others Prog
ramming
5
Condition of New Features
6
Software Compatibility
MPR / LPR
MPR / PC maintenance console
7
Hardware
  • - New Hardware
  • - Power Factor Summary

8
New Hardware
4-channel VoIP gateway VoIP H.323 V.2, ITU-T
G.729a, G.723.1, G.711 T38 (FAX) is not
supported Panasonic proprietary IPGW card
CSIF4
4-port CS interface card for 4 CSs(TDA0142).
TDA200 4 TDA100 2
(4 Cell Station Interface)
KX-TDA0143
2ch CS
Connect to DPT port (CSIF card is not
needed) 2.4GHz (KX-TDA0141), DECT(KX-TDA0141CE)
TDA200 32 TDA100 16
(CS to DPT Port)
KX-TDA0141
MEC
Memory expansion for - Broadcasting
feature - Double the number of DPTs
(DXDP)
TDA200 1 TDA100 1
(Memory Expansion Card)
KX-TDA0105
To be installed in the MEC slot on MPR card
9
Power factor summary (Ver. 1.1)
Calculated with base card, not using base ports.
10
Function - Highlight
  • DXDP Double Extension Capacity
  • New IPGW Card
  • 2ch CS

11
Digital XDP (DXDP) -1
  • - DPT on DPT without additional HW or SW
  • - Easy installation for additional Extensions
  • - 1 DHLC port gt 3 telephones (2x DPT1x SLT)
  • DHLC Card Max 24
    Ext.
  • - 1 DLC port gt 2 telephones (2x DPT)
  • DLC16 Card Max
    32 Ext.
  • DLC8 Card Max
    16 Ext.

DXDP-Slave
or
XDP
12
Digital XDP (DXDP) -2
Capacity for Extension
System Capacity (Trunk Extension mixed)
13
Digital XDP (DXDP) -3
MEC(TDA0105)
How to check the TDA0105
If the TDA0105 is not installed.
If the TDA0105 is installed.
14
Digital XDP (DXDP) -4
Condition-3 - OHCA function can not be used -
T7601 (USB) can not be used (PC Phone / PC
Console / PC Programming)
Parallel Connection !
15
VoIP Gateway Card (KX-TDA0484) - 1
General
- 4ch IPGW Card - G729a/G723.1/G711 - T.38 (FAX)
mode is not supported (FAX G711) - Physical
I/F 10/100 Base-T - Web programming
(English) - Interoperability with
TDA0480 Incoming call, Outgoing call and CLIP
only. - Interoperability with another
manufacturers Not guaranteed.
16
VoIP Gateway Card (KX-TDA0484) - 2
New IPGW Card (Compatibility)
17
VoIP Gateway Card (KX-TDA0484) - 3
New IPGW Card (Interoperability)
18
VoIP Gateway Card (KX-TDA0484) - 4
How to connect TDA0480 TDA0484
Outline of example
Subnet Mask255.255.255.0 Default GW 192.168.1.1
TDA0484
TDA0480
PBX Code 81
PBX Code 82
Switching HUB
A-low
A-low
TRG2
TRG2
IP_Address 192.168.1.200
IP_Address 192.168.1.12
IP_Address 192.168.1.100
Ext.102 TIE Access 7
Ext.103 TIE Access 7
TIE Routing Table Lead 82 Remove 0 Added
none Trunk 02
TIE Routing Table Lead 81 Remove 0 Added
none Trunk 02
Dial 782103 ? 103 of PBX82
Dial 781102 ? 102 of PBX81
19
VoIP Gateway Card (KX-TDA0484) - 5
TDA0484 Setting
20
VoIP Gateway Card (KX-TDA0484) - 6
TDA0480 Setting
DNS Editing
Terminal 81 Remaining digits 3 Selected unit
TDA0484 Unit ICON
21
VoIP Gateway Card (KX-TDA0484) - 7
GW Grouping (Slide Call feature)
In the case that TDA has more than an IP-GW, you
can group these IP-GWs.
Benefit of the GW Grouping Slide Call
In the case that the IP-GW(a) is not available
because all channels are in use for example,
originating IP-GW try the IP-GW(b).
22
2ch Cell Station (KX-TDA0141) -1
- Two Voice Paths per CS. - A specific CS I/F
card is not needed. - A port on DHLC and DLC
cards can used as the interface for KX-TDA0141. -
Max. number of CS TDA10016 TDA20032 (Including
TDA0142). - DHLC/DLC cards software must be 2.005
or later. - Functionality The same as TDA0142 -
Hand-over TDA0141 ? TDA0142 YES - Power
factor is 4.
ø0.4mm 222m ø0.5mm 347m (CAT5) ø0.6mm 500m
DHLC DLC
TDA0141
- CS Port assignment is not needed. The TDA
automatically detects the connected CS (as same
as DPT connection).
23
2ch Cell Station (KX-TDA0141) -2
How to update the CS software
2- Go to SD Card File View and Load
1- Set a CS port to OUS
5- Take the same procedure of Ver.1.0
24
Function Making Calls
  • Broadcasting
  • Dialing Plan
  • Ext. CLIP sending on Emergency Call
  • Short Cut Access to System Speed Dial

25
Broadcasting - 1
An PT user (Owner) can make one way path call (
announce) to 31 parties simultaneously. After one
of called party answering, the owner can begin
announcement. This feature requires MEC(Memory
Expansion Card KX-TDA0105).
Configuration
Operation
2.System - 4.Timers Counters -
2.DISA/DPH/CONF/T.Reminder "Answer Waiting Timer
for Broadcasting Group (s)" 0 - 120
If no member answer, I cancel broadcasting and
send busy tone to the caller.
One Way Path
PT only
8 Groups / System
Override FWD setting
  • - Wired Extension
  • - PS
  • Other PBXs Extension
  • (Only Closed Numbering)
  • - Outside Telephone Number
  • Only available when the networking type of the
    trunk is assigned as private.
  • Up to 32 digits

In case of No Answer, it will be disconnected by
timer.
Max.31 members
Because of DND / PS in XDP Parallel Restrictio
n from TRS/Barring / Call Charge Limit
26
Broadcasting - 2
Conversation during broadcasting
1.To let members join to conversation
LCD Ext.214 wants conversation !
Conversation with the Owner Max.3 Members
(1) The Owner pushed DSS - 212 gt Ext.212 join
to conference
( 4 Party Conference )
(2) The Owner pushed Conf. gt Youngest Member
(Ext.211) join to conference
2.To let members leave from conversation
In above situation, when the owner does following
action
Push DSS-211 Push Transfer Push Flash/Recall
27
Broadcasting - 3
LCD Display in typical condition
In establishing
From an owner Extension, Dial 32 Broadcasting
group number
Owner Extension
Called Extension
In broadcasting
When a member of the group answers the call.
Owner Extension
Called Extension
28
Broadcasting - 4
Additional information
Conditions and Responses of Member Extension
DSS key of Owner Extension which relates with
member extension
If owner extension has DSS key of a member of
broadcasting group and establishes a broadcasting
call, the DSS key does not flash when the called
extension rings. It actually turns red (not
flashing).
29
Dialing Plan
30
Ext. CLIP sending on Emergency Call
It overrides CLIR / CO Line CLIP.
Ext.CLIP is sent to PRI public network as
Location Identification Number, even if CLIR is
set or CLIP mode is CO Line CLIP.
  • This feature works only for Emergency call.
  • E911 service must be enabled.

Yes
31
Short Cut Access to System Speed Dial
Auto JOG or Navi-Down/UP works as short
cut key. --- TDA30 V1.0 too
- TDA100/200 Ver.1.0
Nothing Happens
?
- TDA100/200 Ver.1.1 (TDA30 Ver.1.0)
Allen, David Allen, Steve Azure, Alf
?
?
?
System Directory Name ?gt
?
?
ENTER
?
Daly, Gill Darcy, Nigel Davies, Allan
32
Function Receiving Calls
  • Modified DDI Number is displayed on LCD
  • Disable DSS Flash

33
Modified DDI Number is displayed on LCD
- TDA100/200 Ver.1.0
654201
201
4772111 (CLIP) Line 001 201 (DDI)
Caller 4772111
- TDA100/200 Ver.1.1
4772111 (CLIP) Line 001 654201 (DDI)
34
Improved DSS LED flashing/Pick up call -1
External Call to Extension directly
- TDA100/200 Ver.1.0
The DSS LED on Ext.202 is flashing. The call can
be picked up by pressing the button.
All DSS LEDs flashing look like a Xmas tree. ?
Annoying!!!
- TDA100/200 Ver.1.1
Two options - The DSS LED on Ext.202 will flash.
The call can be picked up by pressing the button.
- The DSS LED on Ext.202 will turn ON. The call
cannot be picked up by pressing the button. Busy
tone is sent if the DSS button is pressed.
Enable DSS LED will flash Disable DSS LED
will turn ON
New program item
35
Improved DSS LED flashing/Pick up call -2
External Call to ICD-Group directly
- TDA100/200 Ver.1.0
The DSS LED on Ext.202 flashes. The call can be
picked up by pressing the button.
- TDA100/200 Ver.1.1
Two options - The DSS LED on Ext.202 will flash.
The call can be picked up by pressing the button.
- The DSS LED on Ext.202 will turn ON. The call
cannot be picked up by pressing the button.
Busy tone is sent if the DSS button is pressed.
Enable DSS LED will flash Disable DSS LED
will turn ON
New item
36
Improved DSS LED flashing/Pick up call -3
It is possible to disable DSS LEDs turning off
for an incoming call.
New item
ON or Flash DSS LED turns ON or flashes for an
incoming call. OFF DSS LED never turns ON nor
flashes for an incoming call.
If the DSS button is pressed when extension is
ringing,
LED Flashing
LED ON
Busy Tone
It is possible to pick up call
LED OFF
Call arrives at extension
37
Function Hold/FWD/TR
  • Disable Hold Recall
  • Disable re-count Ext-CO Duration Limitation

38
Disable Hold Recall
Disable Hold Recall is available if Hold Recall
Timer is 0.
1-240 Hold Recall works 0 does not work
V1.0 does not have.
39
Disable Re-counting Ext-CO Duration Timer
Disable re-count Ext-CO Duration Limitation by
Hold Retrieve
40
Function Conference
  • ISDN 3 party Conference
  • DTMF Tone through a Conference from PT

41
ISDN 3 Party Conference (EURO-ISDN) -1
Adding a Third Party during a conversation using
an ISDN service (Three-party Conference 3PTY
via ISDN)
1st Party
2nd Party
Standard ETS 300 188
New
42
ISDN 3 Party Conference (EURO-ISDN) -2
How to establish a conference (During a
conversation)
PT/PS
Dial desired phone number
Talk to the new party
3-party conference
Press ISDN-Hold
PT/PS
Dial desired phone number
Talk to the new party
3-party conference
43
DTMF Tone Through to Conf.Call from PT
- This will be useful for two parties to listen
to VM message.
Not only SLT user but also PT user can control
Voice Mail.
44
Function Timer
  • Intercept Timer for each time mode

45
Intercept Timer For Each Time Mode
Intercept Timer for Day / Lunch / Break / Night
Intercept timer and DISA intercept timer can be
programmed for each time service mode.
Intercept Timer
1-240 s
DISA Intercept Timer
1-60 s Enable 0 s Disable
46
Function Others
  • SMDR RC/AN Information Output
  • Paging to Another Paging Group

47
SMDR RC/AN Information Output -1
RC (Receive Call) information, it will be
output when TDA receives incoming call. AN
(Answer Call) information, it will be output
when extension user answered incoming call.
SMDR Type format is not changed from V1.0 (Type
A / B / C).
KX-TD SMDR based application can work.
But some of them can not work properly.
Because the detailed Spec. and timing to output
is not same as KX-TD series.
48
SMDR RC/AN Information Output -2
Output Samples-1
- External Call ? Extension (201) ? No answer ?
Caller disconnects
20/02/04 0748AM 201 01 ltIgt203 RC 20/02/04
0749AM 201 01 ltIgt203 0'56 0000'00 NA
- External Call ? Extension (201) ? Answers ?
Disconnects
20/02/04 0822AM 201 01 ltIgt203 RC 20/02/04
0822AM 201 01 ltIgt203 0'11 AN ? Ext.
201 Answers 20/02/04 0822AM 201 01 ltIgt203
0'11 0000'17
Output Samples-2 (DISA)
- External Call ? DISA (270) ? OGM is sent ? No
Answers ? Caller disconnects
20/02/04 0900AM 270 01 ltIgt203 RC 20/02/04
0900AM 270 01 ltIgt203 0'05 AN ?
DISA Answers 20/02/04 0901AM 270 01 ltIgt203
0'05 0000'19 D0
- External Call ? DISA (270) ? OGM is sent ? Ext.
201 answers ? Disconnects
20/02/04 0904AM 270 01 ltIgt203 RC 20/02/04
0904AM 270 01 ltIgt203 0'05 AN ?
DISA Answers 20/02/04 0905AM 270 01 ltIgt203
0'05 0000'09 D0 ? Ext. 201 Answers
20/02/04 0905AM 201 01 ltIgt203
0'00 0000'12 TR
49
SMDR RC/AN Information Output -3
Output Samples-3 (ICD-G)
- External Call ? ICD-G (280) ? Time table is not
started ? No Answers ? Caller disconnects
20/02/04 0842AM 280 01 ltIgt203 RC 20/02/04
0842AM 280 01 ltIgt203 0'05
0000'00 NA
- External Call ? ICD-G (280) ? Time table is not
started ? Ext.201 Answers ? Disconnect
20/02/04 0849AM 280 01 ltIgt203 RC 20/02/04
0849AM 280 01 ltIgt203 0'04 AN ? Ext.
201 Answers 20/02/04 0849AM 280 01 ltIgt203
0'04 0000'00 20/02/04 0849AM 201 01
ltIgt203 0'00 0000'06
- External Call ? ICD-G (280) ? Time table starts
? No Answers ? Caller disconnects
20/02/04 1057PM 280 01 ltIgt203 RC 20/02/04
1057PM 280 01 ltIgt203 0'00 AN ? Time
table starts 20/02/04 1057PM 280 01 ltIgt203
0'00 0000'17
-External Call ? ICD-G (280) ? Wait ? Time table
starts ? No Answers ? Caller disconnects
20/02/04 0836AM 280 01 ltIgt203 RC 20/02/04
0837AM 280 01 ltIgt203 0'10 AN ? Time
table starts 20/02/04 0837AM 280 01 ltIgt203
0'10 0000'19
-External Call ? ICD-G (280) ? Wait ? Time table
starts ? Ext.201 Answers ? Disconnect
20/02/04 1048PM 280 01 ltIgt203 RC 20/02/04
1048PM 280 01 ltIgt203 0'05 AN ? Time
table starts 20/02/04 1048PM 280 01 ltIgt203
0'05 0000'12 ? Ext.201 Answers 20/02/04
1048PM 201 01 ltIgt203 0'00 0000'06
50
Paging to Another Paging Group
  • No additional programming steps are required.
  • - Operation is not changed from V1.0. (
    33PageG.Number(2digits) )

51
Function Programming
  • Programmable COS Name CS Name
  • Ext. CLIP Automatic Generating
  • DDI/DID Name Automatic Generating
  • Wireless XDP Programming from PC

52
Programmable COS Name CS Name
- TDA100/200 Ver.1.0
- TDA100/200 Ver.1.1
COS name
CS name
53
Ext. CLIP Automatic Generating
New function
3450155 3450255 3450355
Increase this number
Delete digit
01
201
20
CLIP 345 01 55
1
345
55
54
DDI/DID Name Automatic Generating
New function
PCC00-UK PCC01-UK PCC02-UK PCC03-UK
12300 12301 12302 12303
Delete digit

1
00
20
PCC00-UK
3
PCC
-UK
55
Wireless XDP Programming from PC
It is possible to program Wireless XDP connection
from the PC maintenance console.

- Assign Wireless XDP PS number. - Click
Apply - Power off-on the Wireless XDP PS for
enabling this programming.
56
Improvement
  • Logical Check
  • PS Hand-over during Conference Call
  • Walking Extension from Fault Extension

57
Logical Check -1
The following extension assignment logical check
function is deleted from the V1.1 PC-Soft. In
programming an extension number that does not
exist, the system will now accept.
1. System - System Operator PBX-Operator 2.
Feature - Tenant Operator 3. Groups - Incoming
Call Distribution Group - Group Setting
Supervisor Extension 4. Groups - Incoming Call
Distribution Group - Member Extension No. 5.
Groups - Idle Extension Hunting Group Member
Extension 6. Groups - Voice (DTMF) Group - Group
Information Extension Number of the SLT Port
Connected to VM 7. Extension - Wired
Extension/Portable Station - Extension Settings
Transfer Recall Destination 8. Optional Device -
DISA - Message Setting 1 Digit AA Destination 9.
Feature - Speed Dial Caller ID - Main Table CLI
Destination 10. CO Incoming Call - DIL Table
Port Setting DIL Destination 11. CO Incoming
Call - DDI/DID Table DDI/DID Destination 12. CO
Incoming Call - MSN Table MSN Destination 13.
Maintenance - Miscellaneous Local Alarm Display
Extension
58
Logical Check -2
What happens?
- TDA100/200 Ver.1.0
1- Open the PC maintenance tool and go to
2.System Operator then 2. PBX Operator
2- Click Apply
Dealer does not know what is wrong!
- TDA100/200 Ver.1.1
Please remember, when programming extension
numbers that do not exist, that the system will
now accept the entry.
1- Open the PC maintenance 2- Go to 2.System
Operator 2. PBX Operator 3- Click Apply
Nothing happens.
59
Logical Check -3
If we program a non-existing number ??
1. PBX-Operator ?OUS mode Extension. 2. Tenant
Operator ?OUS mode Extension. 3. Supervisor
Extension ?No Supervisor Extension 4. ICD Group
Member ?The TDA skips this extension. 5. Idle
Extension Hunting Group Member ?The TDA skips
this extension. 6. VM (DTMF) Group ?VM function
does not work. 7. Transfer Recall
Destination ?The transfer recall goes back to the
transferring Extension. 8. 1 Digit AA
Destination ?The TDA sends the re-order tone. 9.
CLI/DIL/DDI/DID/MSN Destination ?The TDA checks
the following
- Re-order tone - Re-routed to operator
10. Local Alarm Display Extension ? No Alarm
Extension.
60
PS Hand-over during Conference Call
Handover can be made during Conference Call.
  • Both of 2.4GHz model and DECT model
  • No programming required

61
Walking Extension from Fault Extension -1
A Fault extension card can be used for walking
extensions.
Insert and remove a card, the non connected
extensions can be used for walking
extensions. DHLC-8 24 extensions SLC-8 8
extensions DLC-8/SLC16 16 extensions DLC-16 32
extensions
62
Walking Extension from Fault Extension -2
What is benefit ?
One existing extension can be shared to several
users with different extension number.
Ext 233 Part-time worker - A 800-1200 Ext 234
Part-time worker - B 1200-1600 Ext 235
Part-time worker - C 1600-2000 Ext 236
Part-time worker - D 2000-800
727 Extension number PIN
What is Walking Extension access code?
63
To Start TDA100/200 V1.1
  • PC Maintenance Console Compatibility
  • Data Conversion
  • Upgrade PBX

64
PC Maintenance Console Compatibility
TDA100/200 Ver.1.1 PC maintenance console can
maintain TDA100/200 Ver.1.0 PBX, too.
When we access TDA100/200 Ver.1.0
Automatically
65
Data Conversion
PC maintenance console provides a data convert
function. (DSYS Ver.1.0 to DSYS Ver.1.1)
3- Enter new file name and click Save
1- Open the PC Maintenance console and open the
saved DSYS (Ver 1.0).
DSYS 1.0
DSYS-1.1
DSYS 1.1
66
Upgrade PBX
2. Download above files to PBX
4.Connect PC-Soft again and download other files
as PC-Softs dialog box saying.
5.If PC-Soft require reset, reset PBX again, then
you can finish upgrading.
67
Thank you very much !
Write a Comment
User Comments (0)
About PowerShow.com