Title: Impression procedure
1Impression procedure
2Product portfolio for bone level implant
impression procedures
RC
NC
Ø 3.3 mm
Ø 4.1mm
Ø 4.8 mm
Snap-on cap
Snap-on cap
Impression Post (open tray)
Impression Post (closed tray)
Impression Post (open tray)
Analog
Impression Post (closed tray)
Analog
Color coding per implant connection
3Bone Level implant impression concept
- 2 impression techniques
- Open tray impression Closed
tray impression
The choice depends on user preference and the
clinical situation
4Open tray impressionConcept
Intraoral situation
Implant impression post
Analog impression post
5Open tray impressionConcept
- Components
- Impression post (TAN), guide screw (TAN)
- Benefits
- Color-coded components correspond to prosthetic
- connection
- High precision impression
- Clear-cut tactile response for accurate
positioning - Guide screw can be tightened by hand or with the
SCS screwdriver - Adaptable in height (1 retention ring)
- Length synOcta post 2.8 mm
TAN is one type of titanium alloy material
Impression components are intended for single use
only
6Step by step procedureOpen tray impression
7Impression procedure
- Remove closure screw or healing abutment
- Insert impression post and hand tighten screw
with the SCS screwdriver
8Impression procedure
- Take impression with an open tray
- Use an elastomeric impression material
9Impression procedure
- When impression material is set, unscrew and
remove the impression
10Impression procedure
- Screw the implant analog onto the impression
post and cast master model
11Its recommended to articulate the master model
before making the restoration
12Closed tray impressionConcept of snap-on
impression cap
- Components
- Cap (Polymer), Post (TAN), Screw (TAN)
- Benefits
- Color-coded components correspond to prosthetic
- connection
- No additional preparation of tray
- High precision impression
- Clear-cut tactile response for accurate
positioning
Impression components are intended for single use
only
13Closed tray impressionConcept of snap-on
impression cap
NC
RC
Screw retained impression post
Implant level impression
Color coded snap-on cap guide screw
14Step by step procedureClosed tray impression
15Impression procedure
- Remove closure screw or healing abutment
- Insert impression post and hand tighten screw
with the SCS screwdriver
16Impression procedure
- Ensure that the colors match (cap and screw)
and the arrows are positioned in a
buccal-lingual direction - Snap impression cap onto the impression post
17Impression procedure
- Take impression with a closed tray
- Use an elastomeric impression material
18Impression procedure
- Remove the impression
- Remove the impression post from implant
- Mount impression post onto the analog (same
color) - Reposition and snap back into the impression
19Impression procedure
- Cast master model
- Articulate the master model before making the
restoration