Control Rooms

Description:

Control Rooms Serve as operations centers for the control and monitoring of a service or process Flight control rooms Power generation control rooms – PowerPoint PPT presentation

Number of Views:118
Avg rating:3.0/5.0
Slides: 15
Provided by: ymc52
Category:

less

Transcript and Presenter's Notes

Title: Control Rooms


1
Control Rooms
  • Serve as operations centers for
  • the control and monitoring of a
  • service or process
  • Flight control rooms
  • Power generation control rooms
  • Industrial process control rooms
  • Semiconductor fabrication
  • Chemical production
  • Steel and paper production
  • Grain elevators

2
Control Rooms
  • Motor Control Center Rooms/Motor Control
    Centers
  • Motor control equipment and the related control
    circuits to provide automation of production
    machinery

Grain silo MCC
Grain silo MCC
3
Computer Rooms
  • Computer Room
  • A facility established to acquire, analyze,
    process,
  • store, retrieve, and disseminate one or more
    types
  • of data
  • Data Center
  • Data processing center/facility
  • Electronic data processing (EDP) center/facility
  • Information Technology (IT) facility
  • Server room
  • Contains computers and storage/retrieval,
    transmission
  • equipment

4
Control/Computer Rooms
Control/Computer Rooms
  • Fire Protection Needs
  • Class A Class C Fire Hazards
  • Electrically energized equipment
  • Plastic cables, housings, components
  • PVC cabling
  • Printed circuit boards (PCBs)
  • Storage tape
  • Expensive, mission critical equipment,
  • Very sensitive to heat and combustion products
  • Business continuity often critical

5
Control/Computer Rooms Impact of Downtime
FOR A ONE HOUR OUTAGE
  Business Sector Revenue Loss per Hour Productivity Loss per Hour
Financial 9,997,500 3,640
Retail 397,500 2,580
Healthcare 157,500 1,250
Manufacturing 59,930 3,060
Public Sector 0 850
6
Control/Computer Rooms
  • NFPA 75
  • Standard for the Protection of Information
    Technology Equipment
  • NFPA 76
  • Standard for the Fire Protection of
    Telecommunications Facilities

7
Control/Computer Room Protection Automatic
Sprinkler Systems
  • Fire Suppression via heat absorption
  • Primary design objective Fire Control
  • and protection of overall structure
  • Confine fire to point of origin
  • Control of ceiling temperatures to
  • prevent structural damage
  • and fire spread

8
Control/Computer Room Protection Automatic
Sprinkler Systems
  • NFPA 13, Standard for the
  • Installation of Sprinkler Systems
  • Preaction systems
  • Detection
  • NFPA 75 - Smoke detector
  • NFPA 76
  • SFD -Standard Fire detection
  • EWFD early warning fire detection
  • VEWFD very early warning fire detection

9
Control/Computer Room Protection Water Mist
  • Fire Suppression via heat absorption
  • Primary design objective Fire Control
  • and protection of overall structure
  • Confine fire to point of origin
  • Control of ceiling temperatures to
  • prevent structural damage and fire spread

10
Control/Computer Room Protection Water Mist
  • NFPA 750, Standard on Water Mist
  • Fire Protection Systems
  • Low, medium high pressure
  • Detection
  • NFPA 75 - Smoke detector
  • NFPA 76
  • SFD - standard fire detection
  • EWFD early warning fire detection
  • VEWFD very early warning fire detection

11
Control/Computer Room Protection Clean Agents
  • Fire extinguishment via
  • heat absorption
  • Primary design objective
  • Fire Extinguishment
  • and protection of
  • structures contents
  • Rapid detection
  • Rapid extinguishment

12
Control/Computer Room Protection Clean Agents
  • NFPA 2001, Standard on Clean Agent
  • Fire Extinguishing Systems
  • Detection
  • NFPA 75 - Smoke detector
  • NFPA 76
  • SFD - standard fire detection
  • EWFD early warning fire detection
  • VEWFD very early warning fire detection

13
Control/Computer Room Protection Portable
Extinguisher Requirements
  • NFPA 75 Requirements
  • CO2 or halogenated type fire extinguishers
  • must be provided for the protection of
  • electronic equipment
  • Extinguishers must be maintained in accordance
  • with NFPA 10, Standard for Portable Fire
  • Extinguishers
  • Listed extinguishers with a minimum rating of 2-A
  • must be provided for use on fires in
    ordinary
  • combustible materials, such as paper and
    plastics.

14
Control/Computer Room Protection Portable
Extinguisher Requirements
  • NFPA 76 Requirements
  • Portable extinguishers suitable for use on
  • energized equipment and/or ordinary
  • combustible fires shall be provided
  • The selection, placement, and maintenance
  • of portable fire extinguishers shall be in
  • accordance with NFPA 10