Title: John Rys
1DaqBook, DaqScan, DaqLab, Personal Daq, DaqBoard
USB Overview
- John Rys
- Product Support Engineer
2Ethernet DaqBooks
3DaqBook/2001 and /2005
- The /2001 and /2005 models provide
- P1, P2, P3 on the rear panel (vs. front)
- Extended temperature operation (-30C to 70C) (
70C) - Slim 1U high package
4DaqBook/2001 and /2005
- DaqBook/2001 and /2005 are building blocks of a
modular data acquisition system using DBK options
5DaqBook/2020
- The /2020 offers volts, thermocouples frequency,
analog output, and digital I/O all-in-one-box!
6DaqBook/2020 Features
- Thermocouple Measurements
- 14 TC inputs via front-panel mini-TC jacks
- Any TC type can install into any input
- TCs are scanned at 200 kHz/channel
- Additional TC can be added via DBK80 series and
DBK90
7DaqBook/2020 Features
- Voltage Measurements
- 16 differential volts inputs via front-panel BNC
connectors - 13 programmable input ranges from 10 V to 156 mV
- 200 kHz, 16-bit measurements
8DaqBook/2020 Features
- Four 16-bit, 100 kHz DAC outputs via front-panel
BNC connectors - Four 16-bit, 10 MHz frequency inputs via
front-panel BNC connectors (can be combined into
32-bit counters) - Two 16-bit, 1 MHz timer outputs via front-panel
BNC connectors - External Trigger Input and External Clock input
via front-panel BNC connectors
9DaqBook/2020
- Rear-panel P1 connector accepts up to 14 DBK
options (presuming 16 ch options) - Rear-panel P2 connector provides 24 digital I/O
(expandable up to 256 ch with DBK20 family
options)
P1 for analog expansion
P2 for digital I/O
10/100 base T Ethernet
DC power input
SYNC connector
10DaqBook/2020
- Built-in 10/100BaseT Ethernet
- SYNC connectors for multi-box applications
11DaqBook/2020 vs WaveBook/516E
- DaqBook/2020 WaveBook/516
- Speed 200 kHz 1 MHz
- Voltage channels 16 8
- TC inputs 14 0
- Analog outputs 4 0
- Frequency inputs 4 0
- Digital I/O 24 16
- Expansion capacity 256 72
12DBK90
- 56 TC channels for DaqBook systems (not DaqBoard
or LogBook compatible)
13DBK90
- Any TC type can be connected to any input using
standard mini TC connectors - Multiple DBK90s can be attached together
(without cables) - Mounting brackets are available to attach DBK90
to DaqBooks
14DBK90
- Rack-mount kit for large-channel applications
15DBK90
- Reading rate with DBK90 is 1 msec per channel
(vs 5 µsec for other DBK options) - Other channels in the system, such as volts, are
measured at 5 µsec per channel - Up to 896 DBK90 channels can be connected to one
DaqBook
16DaqScan/2000 Series
17DaqScan/2000 Applications
- Add DBK207 for isolated volts inputs
- Add DBK207/CJC for isolated TC inputs
18DaqScanApplications/2000
- Add DBK208 and DBK210 for isolated high-voltage
digital inputs and control outputs
19DaqScan/2000 Applications
- Add DBK85 for 16 differential voltage inputs
DBK85 with rack-mount kit
20DaqScan/2000 Applications
- Add DBK60 for custom applications using DBK cards
DBK60 with cards installed
21DaqScan/2000 Series Features
- 2 DaqScan models provide the same analog I/O,
digital I/O, and frequency I/O as the
DaqBook/2000 - Depending on the model, P1, P2, and P3 are
provided on the rear panel for signal
connections
22DaqScan/2000 vs DaqBook
- 1U high, 19 rack enclosure vs. portable package
- Operates in 0 to 50C (vs -30 to 70C)
- AC powered (vs DC)
- Low-cost digital I/O only version
- Always used along with instruments from other
suppliers - Continuous data transfer from the DaqScan to the
PC - Supported with IVI- COM drivers
23DaqScan/2000 Series Software
- Most customers will write their own application
in either NI LabView, DASYLab, Visual Basic, or
C - DaqView is included for set-up and signal
verification
24DaqLab/2000 Series
Two DBK expansion slots
AC powered
Removable screw terminals
25DaqLab/2000 Series Features
- 16-bit, 200 kHz A/D
- 8 front-panel volts inputs P1 on rear for
analog expansion - 4 front-panel frequency inputs (16-bit, 10 MHz)
26DaqLab/2000 Series Features
- 2 internal expansion slots for analog or digital
DBK expansion cards - 6 front-panel digital I/O lines
- 24 digital I/O via P2 on rear
27DaqLab/2000 Series Features
- Two DaqLab/2000 Series products
- /2001 has four 16-bit, 100 kHz analog outputs
- /2005 has no analog outputs
- Includes DaqView and drivers for NI LabVIEW,
DASYLab, C, Visual Basic, MATLAB
28DBK Signal Conditioner
Solution for Physical Test Applications
29DBK for Analog Output
- DBK2 4 channel card
- 14 bit DAC
- Adds additional analog outputs
- For static output or reference out. (Not a
waveform generator) - Output set at the beginning of the acquisition.
30DBK for Acceleration
- DBK4
- 2 channels
- AC/DC coupling
- Supplies ICP power
- Software selectable 8 pole Butterworth filter
- Simultaneous Sample and Hold
31DBK for Current Loop Control
- DBK5 4 channel card
- 14 bit DAC
- Adds additional analog outputs
- For static output or reference out (not a
waveform generator) - Output set at the beginning of the acquisition
32DBK for Speed, RPM, Tachometers, etc.
- DBK7 converts pulse to DC voltage
- 4 channels
- 1Hz to 100 kHz (analog input)
- 1 Hz to 950 kHz (digital input)
- Inputs from 50 mV to 80 Vp-p
33DBKs for Temperature
- DBK9 - RTD
- 8 channels of 100, 500 or 1000 Ohm RTD inputs
- 3 or 4 wire configuration
- Internal excitation source
34DBK Expansion Chassis
- DBK10 holds 3 cards
- DBK41 holds 10 cards
- Reduces cabling issues
- DBK60 holds three cards
- Uses the DBK600 series connector panels for user
customization
35DBK for Current Loops
- DBK15
- 16 channels
- Header for 250 ohm resistor to convert 4-20 mA
to 1 to 5 V - Also good for straight voltages
36DBKs for Strain, Load Pressure
- 2 channel DBK16, and 8 channel DBK43A
- Quarter, half and full bridge gages.
- Strain based load and pressure sensors.
- Built in filters
- Handles 120 to 1000 Ohm bridges
37DBK for Simutaneous Sample and Hold
- DBK17 and DBK45
- 4 channels
- Eliminates time skew between channels
- User adjustable gain
- Low noise (instrumentation amp per channel)
- DBK45 includes filtering
38DBK for Filtering
- DBK18 and DBK45
- 4 channels
- User adjustable gain
- Low noise (instrumentation amp/ch)
- 5, 10, 100, 500 and 1 kHz filters factory
available (Butterworth) - User can create their own RC combination to
change to corner frequency - DBK45 also has SSH
39DBK for Digital Inputs (P2)
- DBK20 DBK21
- Adds 48 additional digital inputs in groups of 8
bits - Screw terminal or DB37
40DBK for Digital Inputs (P2)
- DBK23 Optically Isolated
- 24 inputs per module
- 3 to 30V inputs
- Monitor switches, contacts or other on/off inputs
41DBK Digital Outputs (P2)
- DBK24 Optically Isolated to 500 V
- Switches up to 60 V
- 24 channels
- DBK25 8 Channel Relay card
- 8 dry contact relays
- Relays latch into position
- Preset power-up state
42DBK Battery Options
- DBK34A UPS / Battery pack
- Connects to an existing AC/DC source and supplies
power when the main source fails.
43DBK for 5B modules
- DBK42 16 slot module
- Connector panel is separate
- DBK44 2 channel card
44DBKs for Thermocouple Measurements
- DBK81, DBK82, DBK83, DBK84
- 7 or 14 channel thermocouple inputs
- 4 Hz, low noise front-end
- Newest addition to the DBK line.
45DBK65
- 8-channel module for attaching powered
transducers to DaqBooks and LogBooks
46DBK65 Applications
- Removable front-panel screw terminals for
connection of 2, 3, 4, or 6 wire transducers - Built-in power supply provides transducer power
of 5, 10, 15, and 24 V, jumper-selectable
per-channel (100 mA max/channel, set via
internal jumpers) - Other voltages between 5 and 20 V are possible if
user installs an internal resistor
47DBK65 Wiring Example
- 2-wire voltage measurement
48DBK65 Wiring Example
- 2-wire transducer with 4 to 20 mA output
49DBK65 wiring example
- 4-wire bridge-based transducer
50DBK85
- 16 differential voltage inputs for 2000 series
products
51DBK85
- DBK80 card in a box with connectors
- 156 mV to 10 VFS input
- BNC signal connection
52DBK55
- 8-channel frequency input module for all DaqBook
and LogBook products
53DBK55
- 8 frequency inputs via front-panel BNCs
- 1 Hz to 950 kHz range
- 12-bit resolution
- AC-coupled inputs up to 80V p-p
- Same as two DBK7 cards
54Personal Daq/3000
- USB 2.0 interface
- Stretched Pdaq package with removable
screw-terminal connections - USB powered
- Includes DaqView/3000 software
55DaqBoard/3000 USB
- USB 2.0 interface
- Stretched Pdaq package with removable
screw-terminal connections - USB powered
- Includes DaqView/3000 software
56Personal Daq/3000
- 1 MHz, 16-bit A/D
- 16 SE/8 DIFF analog inputs
- 24 digital I/O
- 0, 2 or 4 1 MHz, 16-bit analog outputs
- 4 counters 32-bit, 20 MHz
- 2 timers
- 12 MHz scanning of digital input lines
- Up to 12 MHz pattern generation
- Digital I/O Counters synchronous with analog
I/O, but consume NO time slot in scan sequencer - users can scan 1 analog input at full 1 MHz along
with digital inputs and counters - Quadrature encoder capable counter inputs
57Personal Daq Applications
- Portable volts, temperature (TC), frequency,
pulse counting, duty cycle and digital I/O - Lab/desktop measurements(a more-transportable
solution than PC plug-in boards)
58Software
- Personal DaqView
- Links to Excel
- Exports data to several popular formats
- Visual Basic and C drivers
- DASYLab drivers
- NI LabVIEW drivers