MTA-Beam,%20Solenoid,%20Cavity - PowerPoint PPT Presentation

About This Presentation
Title:

MTA-Beam,%20Solenoid,%20Cavity

Description:

Title: Stacking Progress Author: mcginnis Last modified by: popovic Created Date: 6/6/2005 3:41:54 PM Document presentation format: On-screen Show (4:3) – PowerPoint PPT presentation

Number of Views:98
Avg rating:3.0/5.0
Slides: 17
Provided by: mcgi150
Learn more at: http://mice.iit.edu
Category:

less

Transcript and Presenter's Notes

Title: MTA-Beam,%20Solenoid,%20Cavity


1
MTA-Beam, Solenoid, Cavity
  • HP-Vacuum, Cryo-RT
  • RF Cavity
  • Milorad Popovic
  • FNAL

2
Motivation
  • Design cavity than can be operated tested
  • As Open or Closed Cell Cavity
  • Under High Pressure 1000psi or Vacuum 10e-7
  • With 400MeV Proton Beam
  • At Room Temperature
  • At Liquid Nitrogen Temperature
  • With 4 Tesla Magnetic Field

3
Test Results with Mark II
4
Test Results with Mark II
5
Cavity, 806.8MHz, gap 12.6
6
Cavity, 800.0MHz, gap 12.4
7
Cavity, Mark III
8
Pull out, 0.2cm
9
Push in, 0.2cm
10
Sliding plate, -1cm
11
Sliding plate, 1cm
12
Closed Cell, Sliding plate
13
Closed Cell, Sliding plate, 3cm
14
From SuperFish
  • Field normalization (NORM 1) EZEROT
    7.57000 MV/m
  • Frequency
    812.24775 MHz
  • Stored energy
    4.8554590 Joules
  • Using standard room-temperature copper.
  • Power dissipation
    999.4979 kW
  • Q 24792.3 Shunt impedance 46.594
    MOhm/m
  • r/Q 181.305 Ohm
  • Average magnetic field on the outer wall
    25422.6 A/m
  • Maximum H (at Z,R 11,4) 62077.6 A/m
  • Maximum E (at Z,R 7.42678,3.55781)
  • 63.5013 MV/m, 2.42769 Kilp.

15
RF Power
  • Segment Zend Rend Emax
    Power
  • (cm) (cm) (MV/m)
    (kW)
  • --------------------------------------------------
    --------
  • -14.000 0.0000
  • 1 -14.000 2.8000 0.1098
    7.9891E-06
  • 2 -7.0000 2.8000 19.52
    0.1439
  • 3 -7.0000 4.0000 62.27
    10.90
  • 4 -10.000 4.0000 42.74
    89.79
  • 5 -10.000 7.0000 5.114
    86.31
  • 6 -10.000 12.000 5.110
    121.6
  • 7 11.000 12.000 1.645
    381.5
  • 8 11.000 7.0000 5.115
    121.8
  • 9 11.000 4.0000 5.146
    86.41
  • 10 8.0000 4.0000 38.83
    89.92
  • 11 8.0000 2.8000 63.50
    10.96
  • 12 14.000 2.8000 21.42
    0.1438
  • --------------------------------------------------
    --------

  • Total 999.5

16
Questions
  • Mechanical Design - Safety
  • RF Engineering Design
  • Diagnostics
  • Rf pickup
  • Fiber, for light pickup
  • X-ray detectors (pin diodes?)
  • ..
  • Do we wont larger beam pipe?
  • Do we wont large accelerating gap?
  • Do we wont highest peak E field?
  • Do we wont as little as possible of H gas?
  • Do we wont different materials in the beam?
  • All these tests cannot be done like last time,
    over few weekends, can we get longer periods of
    time, weeks ..!
  • Do we wont short/long beam pulses?
  • Is there more tests to be done?
  • ..
  • ..
Write a Comment
User Comments (0)
About PowerShow.com