Title: Masonry Design
1Masonry Design
2MASONRY WALLSCONSTRUCTION TYPE
- Single Wythe
- Cavity
- Prefabricated
- Barrier
- Masonry Veneer
- Masonry Bonded Hollow Wall
3MASONRY WALLSSTRUCTURAL FUNCTION
- Veneer
- Nonloadbearing
- Loadbearing
- Shear
4TYPES OF LOADING
- External Loads
- Gravity
- Wind
- Earthquake
- Earth pressure
5ACCUMULATION OF AXIAL LOAD WITH HEIGHT BEARING
WALL BUILDING
6ACCUMULATION OF AXIAL LOAD WITH HEIGHT BEARING
WALL BUILDING
7AXIAL STRESSES IN BEARING WALL WITH UNIFORMLY
DISTRIBUTED AXIAL LOAD
8AXIAL STRESSES IN BEARING WALL WITH CONCENTRATED
AXIAL LOAD
9ARCHING ACTION BETWEEN MULTIPLE OPENINGS
10FREE-BODY DIAGRAM OF A LINTEL ACTING AS A BEAM
11FREE-BODY DIAGRAM OF A LINTEL ACTING AS AN ARCH
12SHEAR WALL LOAD FROM ROOF OR FLOOR DIAPHRAGM
13ACTION OF HORIZONTAL AND VERTICAL STRIPS ASSUMED
FOR DESIGN
14SPAN-TO-WIDTH RATIOS FOR FLOOR DIAPHRAGMS
15STRUCTURAL ACTIONS ON SHEAR WALLS
16(No Transcript)
17ASTM Standard Reinforcing Bars
Bar Size Designation Diameter (inches) Diameter (inches) Weight lb/ft Nominal Perimeter Nominal Cross Section Area (in2) Bar Size Designation
Bar Size Designation Fraction Decimal Weight lb/ft Nominal Perimeter Nominal Cross Section Area (in2) Bar Size Designation
3 3/8 0.375 0.376 1.178 0.11 3
4 1/2 0.500 0.668 1.571 0.20 4
5 5/8 0.625 1.043 1.963 0.31 5
6 3/4 0.750 1.502 2.356 0.44 6
7 7/8 0.875 2.044 2.749 0.60 7
8 1 1.000 2.670 3.142 0.79 8
9 1 1/8 1.128 3.400 3.544 1.00 9
10 1 1/4 1.270 4.303 3.990 1.27 10
11 1 3/8 1.410 5.313 4.430 1.56 11
14 1 3/4 1.693 7.650 5.320 2.25 14
18 2 1/4 2.257 13.600 7.090 4.00 18
18Required Lap Length of Bars in Inches
Bar Size Diameter (d, in.) 2005 MSJC Allowable Stress Design 2005 MSJC Allowable Stress Design 2005 MSJC Strength MBC 2006 Allowable Stress Design (48d, in.) MBC 2006 Strength Design MBC 2006 Strength Design
Bar Size Diameter (d, in.) 8" CMU 12" CMU 8" CMU MBC 2006 Allowable Stress Design (48d, in.) 8" CMU 12" CMU
3 3/8 15.1 15.1 15.1 18 15.1 15.1
4 4/8 20.1 20.1 20.1 24 20.1 20.1
5 5/8 25.2 25.2 25.2 30 25.2 25.2
6 6/8 42.8 39.3 42.8 36 39.3 39.3
7 7/8 59.4 45.8 59.4 42 45.8 45.8
8 8/8 91.2 60.4 91.2 48 60.4 60.4
Assume bar placed in center, Grade 60 steel,
48" o.c. spacing, and f'm1500psi Where design
tensile stresses are gt 80 of Fs, lap length
shall be increased not lt 50 of the minimum
required length.