Title: Safety studies for MYRRHA
1Safety studies for MYRRHA
- B. Arien, S. Heusdains, H. Aït Abderrahim
- on behalf of the MYRRHA Team and Support
IP-Eurotrans Workshop DM1-WP1.5
Brussels, March 17, 2006
2Contents
- 3 topics
- Enhancement of free convection
- LBE freezing in heat exchangers
- TH modelling of the spallation loop with RELAP
- Future work
3Enhancement of free convection
- Unprotected total LOF and LOH accidents are
beyond MYRRHA Draft_2 design - 2 possible ways to improve natural circulation
- by increasing the DH between core and HXs
- by reducing the pressure losses
- First investigations with a simplified model
- loop model simulating the pool type system
- SITHER code provided with a free convection
module (SITHER-FC) - results are indicative
4Reminder (PDS-XADS) TH analysis results
for unprotected accidents (I)
Transient Fuel Clad LBE Water
LOF Partial (1 EHX check valve failed) OK OK OK OK ?
LOF Partial (1 pump trip) OK OK OK OK ?
LOF Total (4 pumps trip) OK T gt 700C after 7 s OK OK ?
TOP (410 pcm) OK OK OK OK ?
LOH Partial (1 SCS failed) OK OK OK OK ?
LOH Total (2 SCS failed) OK T gt 700C after 9 min OK Boiling after 20 min ?
Partial LOF Partial LOH OK OK OK OK ?
Total LOF Total LOH Melting after 20 min T gt 700C after 5 s OK Boiling after 1 min ?
Overcooling OK OK Freezing after 14 min in PHX 5 min in EHX OK ?
5Reminder (PDS-XADS) TH
analysis results for
unprotected accidents (II)
Transient Fuel Clad LBE Water
SA blockage (2.5) OK Failure OK ?
Spurious beam start-up OK OK OK ?
6Enhancement of free convection strategy of
computation
- Start from SITHER-FC as originally developed for
preliminary studies in the MYRRHA project ? free
parameters - Calibrate SITHER-FC (free parameters) from
Draft_2 design and results obtained with RELAP - 2 possible options for the HXs in emergency
- Emergency HXs (draft_2 design) EHX
- Primary HXs PHX
- Effect of DH increase (DH difference of
elevation between core and HXs) - Effect of pressure loss reduction over the core
- Note spallation loop behaviour in transient
conditions not taken into account in the present
study (very conservative)
7Enhancement of free convection simplified loop
model
- mass conservation
- momentum conservation
- energy conservation (core , HXs, pipes)
Momentum equation in the loop model
- G mass flow rate
- C inertial coefficient
- DpF friction pressure losses (f(G))
- DpP pump pressure head ? 0 in fc mode
- DpB buoyancy pressure
8Enhancement of free convection
SITHER calibration unprotected LOF case
core mass flow rate
temperatures in EHX
max. fuel temperature
max. clad temperature
9Enhancement of free convection
effect of DH increase
max. fuel temperature - PLOF
max. clad temperature - PLOF
DH (m)
PHX EHX
high core 0.81 1.67
low core 3.0 4.0
max. fuel temperature - ULOF
max. clad temperature - ULOF
10Enhancement of free convection
effect of DpF reduction
max. fuel temperature - ULOF
max. clad temperature - ULOF
EHX
PHX
11Enhancement of free convection conclusions
- Effect of DH increase
- Even with large DH emergency EHXs are not able to
keep core integrity in case of unprotected LOF
accident (EHXs are not designed to evacuate
nominal power) - Use of PHXs in emergency situations allows to
mitigate strongly the unprotected LOF effects - Effect of Dpcore reductionrelatively small
benefit - Behaviour of spallation loop should be taken into
account
12LBE freezing in heat exchangers
- LBE freezing in HXs can occur with overcooling in
secondary circuit - In extreme conditions plugging could occur
- If total plugging ? possibility of LOF LOH
- Difficulty to recover the normal operation in
case of plugging
13LBE freezing in heat exchangers HX types
Option 2 boiling water
Option 1 pressurized water
lead-bismuth
water
14LBE freezing in heat exchangers model (I)
- Code WALEBI (LBE/water HX) updated for freezing
- Purely thermal model
- Mechanical effects are not taken into account
(conservative)
15LBE freezing in heat exchangers model (II)
Option 2
Option 1
r solution of
liquid LBE temperature
r frozen layer position (normalized to the
inner/outer tube radius)
water temperature
f(r) function depending on geometry and
thermophysical properties of the materials
freezing temperature
16LBE freezing in heat exchangers results (I)
Option 1
LBE
water
liquid LBE
frozen LBE
water
LBE
Option 2
water
17LBE freezing in heat exchangers results (II)
Frozen layer thickness
Total freezing
Total freezing
Option 1
Option 2
s frozen layer thickness normalized to the
inner/outer clad radius
Tw water inlet temperature
18LBE freezing in heat exchangers conclusions
- Risk of tube plugging seems negligible
- Freezing is less important with option 2
19TH modelling of the spallation loop general
sketch
20TH modelling of the spallation loop RELAP model
21TH modelling of the spallation loop results
Mass flow rate
Difference of free surface levels
22Future work
- Input from and interaction with designers (WP1.1,
WP1.2, WP1.4) are imperative - TH modelling of XT-ADS with RELAP
- CFD simulation of XT-ADS primary system with
FINE\HEXA (SCK?CEN) and CFX (NRG) forced
convection and free convection - Optimization of the emergency cooling system