Caldet Session, Collaboration Meeting - PowerPoint PPT Presentation

1 / 13
About This Presentation
Title:

Caldet Session, Collaboration Meeting

Description:

Caldet Near/Far Analysis Results presented at NDFE Cost & Schedule Review Only a little progress since then Caldet 150 Channels of Near Detector Electronics 6 ... – PowerPoint PPT presentation

Number of Views:25
Avg rating:3.0/5.0
Slides: 14
Provided by: PCUs86
Category:

less

Transcript and Presenter's Notes

Title: Caldet Session, Collaboration Meeting


1
Caldet Near/Far Analysis
  • Results presented at NDFE Cost Schedule Review
  • Only a little progress since then

2
Caldet
  • 150 Channels of Near Detector Electronics
  • 6 planes out of 60 on one side
  • T11 Beamline from Sept. 7 Sept. 15, 2002

Time of Flight
Cerenkov
(not to scale)
3
Preliminary Caldet Electron Analysis
  • Electron cuts a la Trish
  • Cerenkov ADC, TOF-Cerenkov timing, max energy
    near center of plane 1, etc.
  • 3 GeV/c electrons, run 31265

Near MIPs
Far MIPs
4
Caldet Electron Analysis, cont.
  • Not all runs are as nice as 31265
  • 2 GeV/c electrons in 31398.
  • Low response events (below 20 MIPs) common to
    both sets of electronics

Near MIPs
Far MIPs
5
Linearity
  • ND and FD responses track each other reasonably
    well, despite obvious problems with electron
    selection
  • Not well enough typical 3 effects, with high
    statistical precision

Fractional difference
Statistical errors not shown, but much smaller
than differences
Non-containment of electrons?
6
Resolution
  • Less agreement than response plot
  • However, RMS is more susceptible to a handful of
    outliers
  • Effects of missing plane 6 as function of
    electron energy

Electron response RMS as of response
7
Channel Correlation
  • Study individual strip Near-Far response in MIPs
  • Combine several strips for statistics
  • Mostly within ?2
  • There will be different threshold effects between
    the ND and FD in lowest bin

(ND-FD)/.5(NDFD)
2 PEs or less in 1st bin
(ndfd)/2 in PEs
8
Channel Correlation, cont.
  • Test is s(ND-FD) consistent with photostatistics?

Expectation
(ND-FD)/expected error
Observed RMS
20 difference is to be expected due to
secondary emission statistic - comparison
looks reasonable
Ratio of observed over expected RMS
MIPs
9
Looking at Channel Differences
  • Can we study features in Near-Far in QIE space?
  • Low PE stats makes it difficult to characterize
    anything as a function of one side of electronics

N/F-1 vs. Near ADC
N/F-1 vs. Far ADC
10
Trigger Timing
  • We left trigger a bit early to avoid any doubt
    about containing rising edge
  • Alfons/Anatael plot
  • Expect very little energy 6 buckets from rising
    edge O(0.25)
  • Observe more, but its quite constant in energy

All channels
E (mips)
11
To Do
  • Use new Muon calibration
  • Old version had requirement of both ends reading
    out bias in case of threshold difference
  • Add more variables/histograms to analysis DST
  • Almost done
  • Understand Near/Far issues in terms of basic
    channel response
  • E.g., timing? Threshold biases?
  • Understand ND response in terms of QIE
  • Any effect vs. number of slices? QIE Range?
  • Light Injection Data
  • Liz Buckley making progress

12
Stability Studies Dave Reyna
  • Pedestals stability throughout Caldet run

All channels, all pedestal measurements
Single channel history
Some small pedestal drift with time
(temperature?), but only on order of 1 of a PE
13
Stability Studies, cont.
  • Calibration stability over run of 1 week
  • Measure response with charge injection, relative
    to calibration

Single channel ratio of calibrated response, end
of run over beginning of run (1 week)
Fit point
All channels, all measurements
Calibration is extremely stable 0.05 mean, 1
rms
Response ratio
Write a Comment
User Comments (0)
About PowerShow.com