Title: Adding to your


1
(No Transcript)
2
  • Adding to your
  • Diagnostic Station

3
Adding to your ADC Adview
  • You can add functions to your diagnostic
    station. Click on the module that you want to add
  • Pulse oximetry
  • Thermometry
  • Or let us know what modules you would like to
    have by leaving us feedback at
  • www.adctoday.com

4
Adding thermometry
  • The temperature module attaches to the top of
    the BP module. It is made up of the following
    two pieces

Display (Part A)
Holder/Well (Part B)
5
Adding thermometry
  1. Using the power button on the right side of the
    BP module, ensure that the ADC Adview is off.
  2. Remove the cover plate from the top of the BP
    module.

6
Adding thermometry
  1. Slide part A of the temperature module along the
    guides on the top of the BP module from front to
    back until it snaps into place. All the segments
    of the temperature module display will light when
    the modules have been connected correctly.

Display (Part A)
Holder/Well (Part B)
Display (Part A)
7
Adding thermometry
  1. Attach the temperature probe connector to part B
    as follows with the black surface facing
    downward, hold the probe connector end against
    the notches on the probe holder, as shown in red.

8
Adding thermometry
  1. Rotate the connector upwards until it snaps
    securely into place. The black surface faces
    outward and the cord extends upward.

9
Adding thermometry
  • Slide part B onto part A as shown (this connects
    the temperature probe connector to the
    temperature unit connector), and insert the
    temperature probe into the well.

Holder/Well (Part B)
Display (Part A)
10
Synchronizing the modules
  • Turn the device on using the power button on the
    right side of the BP module. At the end of the
    start-up sequence, the temperature module display
    will blank except for the appropriate temperature
    unit icon (F or C). A short beep indicates
    that the ADC Adview is ready.
  • Refer to the ADC Adview users manual for
    operation, maintenance and safety instructions.
  • Need help?

11
Changing the unit of temperature measurement
  • Using the end of a paper clip or similar tool,
    press the recessed button on the temperature
    module. The icon for the selected unit is
    displayed.

12
Adding pulse oximetry
  • The pulse oximetry module attaches to the
    bottom of the BP module. Included in the Pulse
    Oximetry Module kit are the pulse oximetry
    module, the adult reusable sensor, and a 6
    extension cable.

13
Adding pulse oximetry
  1. Using the power button on the right side of the
    BP module, ensure that the ADC Adview is off.
  2. Remove the cover plate from the bottom of the BP
    module.

14
Adding pulse oximetry
  1. Slide the pulse oximetry module along the guides
    on the bottom of the main BP module from front to
    back until it snaps into place. All the segments
    of the pulse oximetry module display will light
    when the modules have been connected correctly.

15
Adding pulse oximetry
  1. Turn the device on using the power button on the
    right side of the BP module. At the end of the
    start-up sequence, the pulse oximetry module
    display will blank except for the SpO2 symbol.
  2. Turn the device off, connect the adult reusable
    sensor to the 6 extension cable, and then the
    cable to the connector on the module. Secure the
    cable to your device using the retention clip.

16
Synchronizing the modules
  • Turn the device on. All display segments light
    up for three to five seconds. A short beep
    indicates that the ADC Adview is ready.
  • Refer to the ADC Adview users manual for
    operation, maintenance and safety instructions.
  • Need help?

17
Need help?
  • Contact us by telephone
  • 1.800.232.2670 or 1.631.273.9600
  • Or by email
  • CustomerService_at_adctoday.com
  • Or find help on the Internet
  • www.adctoday.com