Power Supply System Impacts
  • WBS 1.1.3 Power Supply System
  • Level 3 Manager
  • Nancy Grossman
  • FNAL
  • Dec 11, 2001

2
Update of PS Needs
  • V109 has one more 6-3-120 (now 4 instead of 3)
    and runs at a higher current (1050 amps)
  • Requires another 500 KW supply to get the needed
    volts.
  • Have space for 1 more 500 KW in TSB.
  • Only remaining 500 KW PS are old Transrexs, we
    are checking on getting an additional one (or
    other options, and checking the ramp).
  • V110 has one less EPB (now 5 instead of 6) and
    runs at a higher current (1400 amps)
  • Does not require an PS changes, will need to
    re-calculate the ramp.
  • Q109 is now two different quads (3Q120, 3Q60)
    which can run on one supply.
  • Two possible 3Q120s (quads) in the carrier
    tunnel (unlined region)
  • Will need an additional PS each (there is room
    for them and we have spares)
  • Cable lengths and costs all need to be
    re-estimated.

3
Update of Regulation Needs
  • Magnet Strings regulation requirements are looser
    with the new beam optics.
  • Could use less regulation than we have budgeted
    for, if this remains true.
  • Not clear if loosening the regulation is worth
    the money saved.
  • Dont need to decide until FY2003.
  • Costed filters for all 7 strings, and BmLB
    systems for 3 strings, HOLEC transductors and
    special FNAL electronics for all 7 strings.

4
Summary
  • All these comments are very preliminary and
    Steve Hays will check in detail to see what are
    the final implications.
  • Main Changes
  • Need extra 500 KW for V109.
  • Need 2 more quad PS if put quads in carrier
    tunnel.
  • PS regulation requirements are looser.
  • Cable lengths and numbers.
  • (need to re-do ramp calculations and cable
    calculations/costs)
  • Implications
  • Can we get additional cable (500 kcm) or is it
    too late? Not sure if we will need it or not
  • Additional costs are for 500 KW PS and quads and
    cables. Estimate several tens of thousands of
    dollars (FY98).
  • Might be able to save money on PS regulation, but
    we would need to think long and hard before doing
    that.