Title: Laboratory of Bioenergetics
1Laboratory of Bioenergetics
- main laboratory 3.2.11, 3.2.11a
- climatic chamber 3.2.11
- animal rooms 3.0.xx
- administrator Pawel Koteja
- Evolutionary Physiology Research Team
2Respirometric system Sable TR3
Main location 3.2.11
- oxygen analyzer - Oxzilla
- - 2-channel
- - 0-100, res. 0.001
- CO2 analyzer - CA2A
- - 0-10, res. 0.0001
- continuous measurement on 1 or 2 ch.
- sequential on 8-16 ch.
- open flow-through or semi-closed system
- from microorganism cultures (as Microoxymax) to
large animals - a small climatic chamber
- mobile
3Respirometric system Sable TR3
Main location 3.2.11
Example of an open-flow setup measurement of the
maximum exercise-induced rate of aerobic
metabolism
4Respirometric system Sable TR3
Main location 3.2.11
Example of an open-flow setup measurement of the
maximum exercise-induced rate of aerobic
metabolism
5More devices for respirometric measurements
- O2 analyzer Applied Electrochemistry (AMETEK)
S3/AII - 2-channel, 0-100, res. 0.001, very
fast, stable, lab. use only - 2 x O2 Sable analyzer FC-10A
- 1-channel 0-100, res. 0.001, slow, not
stable, mobile, 12V - CO2 analyzer Sable CA10A
- 1-channel, 0-10, res. 0.0001, fast,
stable, mobile, 12V - CO2 and H2O analyzer LiCor LI-840A
- Low cost "two in one", mobile,
parameters similar to CA10A - Several pumps, mass flow controllers, channel
multiplexers, air driers, etc.
6Motorized treadmillfor respirometric measurements
- mouse-sized animals
- speed up to 6 km/h
- computer controlled speed regulation
- manual angle control
- waterproof
7Activity detectors passive infrared
Custom made 3M Mouse Motion Monitor
- 64 sensors
- expandable
- elastic system of data acquisition
- time resolution 0.01 sec.
- mobile animal rooms, climatic chambers
8Activity detectors - mechanical
Sable MAD- 1 ("seismographs")
- 8 sensors
- elastic system of data acquisition
- time resolution 0.01 sec.
- mobile animal rooms, climatic chambers
9Video system for behavioral analyses
Noldus Ethovision
- video cameras, multichannel recorders
- analog-digital converter ("frame grabber")
- video analysis system
- main result path of animal movement
- detection of a few individuals in one arena
- detection in several arenas (with one individual
in each) - several characteristics of movement speed, time
in particular zones, "meandering" - automated trials for standard behavioral tests
- open field
- Morris water maze
- multi-arm labyrinths
10Automatic extraction apparatusBüchi B-811
- 4-positions
- temperature regulation up to 150C
- extraction in neutral gas
- automated
- phases of the process (extraction, rinsing,
drying) - various types of extraction
- programmable sequences
11Automatic extraction apparatusBüchi B-811
Types of process
12Hydrolysis apparatus Büchi B-811
- 4 positions
- vials compatible with the extraction apparatus