Title: PharmSpec 3.0


1
PharmSpec 3.0
  • HIAC just got easier!

2
PharmSpec 3.0
  • Many of the functions have not changed
  • Procedural tests
  • Run Counter tests
  • IST tests
  • Procedure Builder
  • Historical reporting
  • Activity Log
  • Data Storage
  • Hardware settings

3
Bubble Detection Alarm
1) Clear description of alarm
2) Recommended actions
3) Potential cause and where to go for help
Ships disabled as standard.
4
Invalid Configuration Alarm
  • Current 9703 does not validate that the
    instrument configuration is not suitable for use
  • New 9703 will
  • Ensure the sampling probe, syringe, and flow rate
    setup are viable configurations
  • The strength of the 9703 is its ability to manage
    a wide range of LPC application
  • We tested all possible mechanical configurations
    to ensure the instrument is not a contributor to
    bubble generation

5
Concentration Limit Alarm
  • Warns the user if the sensor detects excessive
    concentration in the sample
  • A standard input during hardware setting

6
Sensor Contamination Alarm
  • Warns the user that the sensor is contaminated
  • Probable causes
  • Sensor window/cell is dirty
  • Void (air pocket) passed through the sensor
  • Significant over concentration of the sensor
  • Recommendation
  • Forward-flush the system multiple times with
    cleaning solution
  • For protein-users, we recommend Conrad 70

7
PHA
  • PHA enables
  • Troubleshooting
  • Secondary sizing validation
  • Diagnostic
  • Dual channel PHA
  • Light Scattering
  • Light Extinction
  • Changes
  • Utilizing histogram
  • Added scatter

8
Batch Export
  • Current version of PharmSpec 2.X only allows 1
    test to be exported
  • PharmSpec 3.0 will enable mass or selectable
    export functions to
  • Word
  • Excel
  • Adobe
  • Text

9
Electronic Signature Improvements
  • More strict interpretation of 21CFR Part 11
    electronic signature process. WITHOUT more
    manual inputs

10
Calibration Due Alarm
  • Advanced awareness that your instrument is due
    for Calibration
  • Configure your calibration due warning timeline
    or turn it off

11
Probe Change Warning
  • Sampling safety switch
  • Ensures the sampling probe does not crash (and
    bend or break) into the docking module.
  • Ensures the probe does crash and/or tip the
    sample container

12
Configure Alarms and Alerts to Suit
  • Turn them On!
  • Turn them Off!
  • Or do both!
  • Factory default is off

Ships disabled as standard.
13
Manage Multiple Alarms
14
Customized Reporting
15
Customized Reporting
16
Automation of Flush Routine
  • Give your customers more walk away time
  • Automate flushing/cleaning routines
  • Step 1 Place 1 ml - 1000 ml of Conrad 70, IPA,
    or other cleaning solution
  • Step 2 Push a button
  • Step 3 Walk away
  • Step 4 Return to a thoroughly cleaned instrument

Estimated time savings 20 - 30 minutes minimum
17
RD Partial Results Are Captured