Lynx Series Lynx Plus LynxR-2 LynxR-EN LynxR-i LynxR-iSIA - PowerPoint PPT Presentation

1 / 55
About This Presentation
Title:

Lynx Series Lynx Plus LynxR-2 LynxR-EN LynxR-i LynxR-iSIA

Description:

Title: Lynx Series Web Training Subject: LynxR, LynxR-EN, LynxR-i & ReadyGuard Sister Products Author: Troy Barnes & Mike Price Last modified by – PowerPoint PPT presentation

Number of Views:88
Avg rating:3.0/5.0
Slides: 56
Provided by: Troy83
Category:
Tags: lynxr | basic | isia | lynx | plus | series | training

less

Transcript and Presenter's Notes

Title: Lynx Series Lynx Plus LynxR-2 LynxR-EN LynxR-i LynxR-iSIA


1
Lynx SeriesLynx PlusLynxR-2LynxR-ENLynxR-iLyn
xR-iSIA
2
Agenda
  • Panel Features
  • Connecting an AlarmNet Communicator
  • Programming Locations
  • 56 Enhanced Zone Programming
  • 80 Device Programming
  • 81 Zone List Programming

3
Features
  • AlarmNet Communicator Compatible
  • IP/GSM Downloading Compatible
  • Wireless Siren Compatible 5800WAVE
  • Wireless Keypad Compatible 5828V Fixed English
  • Built in Speakerphone
  • Built in Remote Phone Control
  • Built-in Two-way voice system - AAV
  • Numeric Pager Reporting
  • Follow-Me Alarm Reporting (voice message)
  • Options of the Lynx Plus, LynxR-2 and LynxR-i
  • Central Station reporting required for Pager and
    Follow-Me Alarm reports except for Open and Close
    reports

4
Plus Features
  • Supports two-way voice over GSM radio
  • with the GSMVLP radio module
  • Full 16-button keypad with easy-to-read LCD
    display and status LEDs
  • 2 x 16 Custom Alpha backlit display
  • Hinged cover for simpler installations

5
Features
  • Rechargeable batteries
  • 6 x 1.2V Nickel Metal-Hydride pack
  • provides 24 hours of standby
  • Enhanced Enroll Mode
  • Can enroll Confirm serial number
  • View serial number
  • Change loop number w/o deleting
  • RF jam detection

6
Features
  • 1 Hardwire zone Not present on LynxR-2 or
    LynxR-i
  • 24 Wireless zones
  • 16 Button zones
  • 5804, 5804BD, BDV, 5802MN
  • 8 user codes
  • 1 installer
  • 1 master
  • 1 duress
  • 5 standard
  • 84 Event log Viewable from Compass Only
  • On-board UL 85db siren

7
Lynx Series AlarmNet Connections
8
AlarmNet Communicator
GSMVLP
Status LEDs
Signal Strength LED Must be solid.
Registration and Test Switch
9
Lynx Plus AlarmNet Communicator Mounting
Installing the GSMVLP Module
10
AlarmNet Communicator Connection
Wiring Connections and Routing
11
AlarmNet Communicator
GSML
Status LEDs
Signal Strength LED Must be solid.
Registration and Test Switch
12
AlarmNet Communicator
GSML
13
AlarmNet Communicator Connections
LynxR-2/R-i 7847i-L Configuration B
14
AlarmNet Communicator Connections
LynxR-2/R-i 7845GSM / 7845i-GSM
Do Not Connect the 7845GSM internal battery!
NOTE DC Power is supplied from Lynx panel.
15
AlarmNet Communicator Connections
LynxR-2/R-i 7847i
16
AlarmNet Communicator Connections
LynxR-EN AlarmNet Device
2K Ohm Pull up resistor.
Program your AlarmNet Device in V- (neg) Zone
Mode.
17
AlarmNet Communicator Connections - LynxDM-GSM
18
AlarmNet Communicator Connections
LynxDM-GSM
19
Lynx Series Programming
20
Programming Locations
20 Installer Code
4112
Example 1
To change the Inst. Code you would enter 20 then
the new code For example Change Installer
code to 4321 2 0 4 3 2 1 (after entry of
last digit the keypad will beep 3 times to
confirm the entry and automatically proceed to
location 21)
21
Programming Locations
20 Installer Code
4112
Example 1
To view what is in location 20 you would
enter 2 0 the panel will then display the
location contents one digit at a time (in
hexadecimal format) For example 2 0 then
the panel would display 04 (beep) 03 (beep)
02 (beep) 01 (beep, beep, beep) The installer
code is 4321. A triple beep is heard after the
last digit of the field is displayed.
22
Programming Locations
1
0 no 1yes
21 Quick Arm Enable
0 0 always on 1 off after 10secs
22 Keypad Backlight Time Out
24 RF House ID Code
00 00 disable 01-31 house ID
23
Programming Locations
25 Powerline Carrier device House Code
0
26 Chime by Zone
0 0 no 1 yes
Program zones to chime on zone list 3
0 0 no limit
31 Single Alarm Sounding/Zone
1 yes, once per arming
0
31 Single Alarm Sounding/Zone SIA
0 Same as Shutdown in field 92 1 yes, once
per arming period
1 0 none 1 4min
33 Alarm Bell Timeout
2 8min 3 12min 4 16min
24
Programming Locations
Daylight Saving Time
3,11
29 Daylight Saving Time Start/End
Month
This is March and November.
30 Daylight Saving Time Start/End
Weekend
2,1
This is the 2nd Sunday in March and the 1st
Sunday in November.
25
SIA Entry Exit Times
6,0 00-99 exit delay time (in sec) 97
120 sec delay
34 Exit Delay
SIA Must be set to a minimum 45 sec.
3,0
35 Entry Delay 1 (zone type 01)
30-96 entry delay time (in sec.) 97 120 sec
98 180 sec 99 240 sec
SIA The entry delay must be set to a minimum of
30 seconds. The sum of entry delay 1 field 35
and the burglary abort window entered in 50
should not exceed 1 minute.
26
SIA Entry Exit Times
3,0
36 Entry Delay 2 (zone type 02)
30-96 entry delay time (in sec.) 97 120 sec
98 180 sec 99 240 sec
SIA The entry delay must be set to a minimum of
30 seconds. The sum of entry delay 2 field 36
and the burglary abort window entered in 50
should not exceed 1 minute.
0 0 no 1 yes
50 15 sec Dialer Delay (Burg)
2 1 15 sec 2 30 sec 3 45 sec
50 Burglary Abort Window SIA
27
Phone Options
0
38 Confirmation of Arming Ding
0 no 1 yes (when armed by self-contained
keypad or RF) 2 yes (when armed by RF only)
40 PABX Access Code SIA PABX/Call Waiting
Disable 41 Primary Phone No.
Up to 6 digits
...
Up to 20 digits
28
Phone Options
42 Secondary Phone No.

Numeric Pager or Follow-Me Alarm
Up to 24 digits
  • 43 Primary Account Number
  • 44 Second Account Number

4 or 10 Digits
FFFF
4 or 10 Digits
FFFF
The Account Number will be 10 digits only if 10
Digit Contact ID Format is selected in 48 Report
Format.
29
Phone Options
46 Follow-Me Reminder Phone Number

Up to 24 digits
5
47 Phone System Select
Central Station Dialing Mode Dialing Mode Dialing Mode Dialing Mode
Central Station Pulse Tone Pulse Tone
No WATS 0 No Speaker Phone 1 No Speaker Phone 4 With Speaker Phone 5 With Speaker Phone
WATS 2 No Speaker Phone 3 No Speaker Phone 6 With Speaker Phone 7 With Speaker Phone
30
Phone System Select
SIA Only
SIA Only
5
47 Phone System Select
31
Format
48 Report Format for PRIM/SEC.
7,7
Primary Secondary
0 31, 41 Ademco L/S Standard 6 or undefined
42 Ademco Express 1 31 41 Radionics
Standard 7 Ademco Contact ID reporting 2 42
Ademco L/S Standard 8 31, 41 Ademco L/S
Expanded 3 42 Radionics Standard 9 31, 41
Radionics Expanded 5 Ademco 10 Digit Contact ID
Format
NOTE Option 5 or 7 (Ademco Contact ID) must be
selected for AAV.
ADEMCO Contact ID Example
1234 E 131 00 C005 This is a new Perimeter Alarm
on Zone 5, Account , the Event (E new, R
restore ) Event Code, Zone
32
Reporting Options
Dialer Programming
0 0 Disable (Backup report only)
49 Split/Dual Reporting
TO PRIMARY PHONE No. TO SECONDARY PHONE
No. 1 Alarms, Restore, Cancel Others 2 All
except Open/Close , Test Open/Close, Test 3
Alarms, Restore, Cancel All 4 All except
Open/Close, Test All 5 All All TO
PRIMARY PHONE No. TO PAGING No. (Secondary) 6
All except Open/Close Alarms, Open/Close,
Troubles 7 All reports Alarms, Trouble 8
All reports Alarms, Open/Close, Troubles 9
All except Open/Close Open/Close TO
PRIMARY PHONE No. TO Follow-Me Alarm No.
(Secondary) 10 All except Open/Close Alarms,
Open/Close, Troubles 11 All reports Alarms,
Trouble 12 All reports Alarms, Open/Close,
Troubles 13 All except Open/Close Open/Close
Will report users 0, 5-8 or wireless arm/disarm
button Zones 26-33 all other zones and users do
not report
33
Periodic Test
0 0 none 1 24 hrs
51 Periodic Test Report
2 weekly 3 30 days
2 0 24 hr 1 6 hrs
52 First Test Report Offset
2 12 hrs 3 18 hrs
1,0
64 Test Report Code
0,0
76 Test Restore Report Code SIA Sent when test
mode is exited.
34
Programming Locations
59 Exit Error Report Code
1
60 Trouble Report Code
1,0
0
65 Open Report Code
66 Arm Away/Stay Rpt Code
0,0
AWAY
STAY
35
Programming Locations
55 Enable LRR/IP Communications Device
0
0 Disable 1 Enable
77 Dynamic Signaling Delay/ Dynamic
Signaling Priority
0, 0
1st Entry (delay before switching Central
Station reporting path)
2nd Entry 0 Primary Dialer First 1 LRR/IP
First 2 LRR/IP Reporting Only
0 Redundant reporting 1 15 seconds 2 30
seconds 3 45 seconds 4 60 seconds 5 75
seconds 6 90 seconds 7 105 seconds
8 120 seconds 9 135 seconds 10
150 seconds 11 165 seconds 12 180 seconds
13 195 seconds 14 210 seconds 15 225
seconds
36
Programming Locations
  • 87 Aux Function 1-button paging or Macro
  • Send 999-9999 to a pager or can be a Macro
  • 88 Pager Characters
  • Enter up to 16 digits as needed for customizing
    pager messages or pager requirements (PINs
    etc.)

90 Event Logging
3
0 None 1 Alarm/Alarm Restore 2
Trouble/Trouble Restore
4 Bypass/Bypass Restore 8 Open/Close To
select all, enter 15
37
Programming Locations
91 Alarm Audio Verification/Remote Phone Control
2
0 None 1 AVM remote phone control 2
remote phone control only 4 AVM only
92 Number Of Reports in Armed Period
0
0 10 Alarm/Alarm Restore Reports 1 Unlimited
1
92 Swinger Shutdown SIA
1 shutdown after one alarm 2 shutdown after
two alarms
38
Programming Locations
94 Download Phone No.

Up to 20 Digits
95 Ring Detect Count for Downloading
0
0 Disable Station Initiated Download
1-14 Number of rings 15 Answering
Machine Defeat
39
Programming Locations
96 Initializes Download ID, Subscriber Account
No. For Initial Download No entry
required 97 Select 1 of 4 Default Option
Setups. Enter 1-4 to select from
default tables 1-4. Enter 0 to abort. 98 Exits
Programming mode and prevents re-entry by
Installer Code 800 99 Exits Programming
mode and allows re-entry by Installer
Code 800
40
Lynx Series 56 Enhanced Zone Programming
41
56 Enhanced Zone Programming
Zone Number Enter the 2-digit zone number to be
programmed Continue 00 exit zone
programming mode
A 02
A 02 ZONE NUMBER
Zone Type
b 01
Enter the 2-digit zone type. Continue
b 01 ENTR/EXIT1 ZONE TYPE
00 Not Used 08 24 Hr. Aux
01 Entry/Exit 1 09 Fire without verify
02 Entry/Exit 2 10 Interior w/Delay
03 Perimeter 20 Arm-Stay
04 Interior Follower 21 Arm-Away
05 Trouble Day/Alarm Night 22 Disarm
06 24Hr. Silent 23 No Alarm Response
07 24Hr. Audible 24 Silent Burglary
42
56 Enhanced Zone Programming
C 10
Report Code
C10 REPORT CODE
Enter the report code
Input Type
d 3
Enter the input type 3 Supervised RF (RF) 4
Unsupervised RF (UR) 5 Button type (BR)
Continue
d 3 RF SUPERVSD INPUT TYPE
E 1
Loop Number
E2 LOOP/AUTO LEARN
  • It takes 4 transmissions to learn in the Serial
    and Loop Numbers.
  • 1st Fault and Restore a single beep will sound.
  • 2nd Fault and Restore a double beep will sound.
  • If a voice descriptor is already programmed for
    the zone, it will also be announced.

43
56 Enhanced Zone Programming
E 2L
An L will appear after the loop number if the
loop number was learned in.
E2L LEARNED LOOP/AUTO LEARN
1A L
1AL A000-1234 ENROLL MODE
Enroll Mode
0 Skip to the VOICE DESCRIPTOR prompt (1C) 1
Enroll now and proceed to SERIAL NUMBER prompt
(1b) (If L is not displayed) 2 Copy the
last serial number from the local memory buffer
(If L is not displayed) 3 View existing
serial number. (Only if L is displayed) 9
Delete existing serial number. (Only if L is
displayed) Advance to the VOICE DESCRIPTOR
prompt (1C)
44
56 Enhanced Zone Programming
Manual Serial Number Entry
1A
Press 1 at the 1A prompt to manually enter the
transmitters serial number
1A ENROLL MODE
1b
Manually enter the transmitters 7-digit
serial number. When all 7 digits are entered,
press the key.
1b SERIAL NUMBER
1A L
After entry is completed, you may trip the
transmitter to confirm the serial number entry is
correct, or press to skip.
1AL A000-1234 ENROLL MODE
45
56 Enhanced Zone Programming
1C
  • Voice Descriptor
  • (Can also be entered separately in 84)

1C ZONE DESCRIPTOR
0 skip to next zone 1 Enter descriptor mode
1d 47
Descriptor 1
1d47 Front
Enter 2 digit vocabulary index number 6
accept word and advance to descriptor 2 8
accept word and advance to next zone
FRONT
46
56 Enhanced Zone Programming
1E 69
Descriptor 2
1E69 Sliding
Enter 2 digit vocabulary index number 6
accept word and advance to descriptor 3 8
accept word and advance to next zone
SLIDING
1F 12
Descriptor 3
1F04 Door
Enter 2 digit vocabulary index number 8
accept word and advance to next zone (A prompt)
DOOR
A 03
A03 ZONE NUMBER
00 exit zone programming mode
47
Lynx Series 80 Device Programming
48
80 Device Programming
Device Programming
80
0 Exit mode 1 Enter mode
80 DEVICE PROG MENU
Device Number
A01
Enter the 2-digit device number 01-08
X-10 09-16 Multi-Mode Total Connect
Continue 00 Exit Device Programming mode
A01 DEVICE NUMBER
Device Action
b 2
Enter the 1-digit action 0 No response 1
Close for 2 seconds 2 Close and stay closed
3 Pulse on and off Continue
b02 DEVICE ACTION
49
80 Device Programming
Start Event Type
C 2
C02 START EVENT TYPE
Enter the 1 digit start event type 0 Not
used 3 Trouble 1 Alarm Continue 2
Fault
d 1
Start Zone List
d01 START ZONE LIST
Enter the 1 digit zone list number, 1-3, or
0 if not used Continue
50
80 Device Programming
Start Zone Type
E 00
Enter the 2-digit start zone type Continue
E00 START ZONE TYPE
F 0
Stop Zone List
F00 STOP ZONE LIST
Enter the 1-digit zone list number, 1-3, or 0 if
not used Continue
Stop Zone Type
1A22
1A22 STOP ZONE TYPE
Enter the 2-digit stop zone type Return to
Device Number prompt (A)
A02 DEVICE NUMBER
A02
51
Lynx Series 81 Zone Lists
52
81 Zone List Programming
Zone List Programming
81
0 Exit mode 1 Enter mode
81 ZONE LISTS MENU
Zone List Number
A01
A01 ZONE LIST NUMBER
Enter the 2-digit zone list number (01-03)
Continue 00 Exit mode
Zone Entry To List
b28
Enter the 2-digit zone number Accept zone
number and enter the next zone number 00 Accept
zone number and continue to next prompt
b28 ZN ENTRY TO LIST
53
81 Zone List Programming
C
Delete Entire Zone List?
C DEL WHOLE ZN LST
0 Dont delete continue to next prompt 1
Delete the current zone list
Delete Specific Zones from List?
d
0 Dont delete continue to next zone list
number 1 Continue to delete zones prompt
d DEL 1 ZN FRM LST
Delete Zones
E
Enter the 2-digit zone number to be deleted
Delete zone 00 Return to next zone list number
E00 DELETE ZONES
54
Review Quiz
  • How do we view what is in a standard programming
    location?
  • How do we enter data in standard programming
    location?
  • What programming mode do we use to program in
    wireless transmitters?
  • Does the LynxR-EN have an event log?
  • Will the system report in Contact ID with an
    AlarmNet Communicator?

55
http//www.security.honeywell.com/hsc/ and click
on MyWebTech User name honeywell Password
support99 Honeywell Security support e-mail
mywebtech_at_honeywell.com
Write a Comment
User Comments (0)
About PowerShow.com