Title: Galaxy V Series (VM)
1Galaxy V Series (VM)
Catalog
John Goosseff Business Development, 3 Phase Power
2Galaxy VM Product Messaging
- Elevator pitch
- Galaxy VM is Schneider Electrics latest 3 phase
UPS that provides very high efficiency, is easy
to deploy, and seamlessly integrates into the
electrical , physical and monitoring environments
of customers operating medium data centers,
industrial or facilities applications.
3A history of leading innovation
From product leadership
Symmetra
Science Center created to advance thought
leadership of data center design operation
- APC PowerChute software revolutionizes power
management
Industry's first modular UPS Matrix-UPS is
introduced MGE Galaxy line is launched
APC purchases Silcon A/S, enters 3 Phase UPS
market
First 3-phase UPS by Merlin Gerin
scalable, redundant UPS introduced
1999
1998
1993
1997
1989
1981
1964
1st Schneider Electric branded V Series UPS. 1st
to Market 98 ECOnversion UPS Module
Symmetra PX500 1st Double Conversion 96
Efficiency UPS Released to MKT
Introduced, integrating power, cooling, racks,
Management and service
MGE Introduces first 800kVA UPS to the market
APC introduces its first (NCPI) architecture,
PowerStruXure
APC revolutionizes cooling market
NetBotz acquired by APC
2014
2008
2002
2003
2005
to Solution leadership
4Galaxy VM Applications
180-225kVA 60Hz 160 -200kVA 50Hz
- Small/Medium Datacenters
- Data storage equipment
- Network equipment
- Computer room equipment
- Commercial buildings
- Facilities
- Banks
- Hotels
- Industrial environments
- Manufacturing equipment
- Control automation
- Emergency lighting
- Telecom
- Wireless communication
- Mobile and fixed telephone infrastructure
- Radio and TV broadcasting
5Galaxy VM Customer Profile
- Decision makers, Influencers
- Electrical Contractors, Installers
- Facilities managers and Chief Electrical Engineer
- Specifiers, Consulting Engineering Companies
- EPC (Engineering, Procurement Construction)
- Customers
- Medium companies linked to service, manufacturing
and process industries - Large international accounts and their
branches/regional offices - Telecom operators and equipment manufacturers
6Schneider Electric 3 Phase UPS PortfolioChanges
in the next 3 to 24 months
UPS Ranges 95 to 97 Efficiency
Symmetra MW 500-1600kVA
Symmetra PX
400-1600 kVA
10-500 kVA
UPS Ranges 91 to 94 Efficiency
Smart-UPS VT
10-30 kVA
MGE Galaxy 5000
MGE Galaxy PW
MGE EPS7000, 8000
MGE Galaxy 3500
300-1100 kVA
480V 50-130 kVA
150-225 kVA
MGE Galaxy 4000
10-30 kVA
208V 40-75 kVA
800kVA
10kVA
30kVA
200kVA
IT Non-IT
IT Datacenters
Non-IT
7Galaxy VM and the range it replaces
VM
Q1-2015
Q1-2015
Q1-2015
Q3-2014
Q1-2014
Q1-2015
kVA (UL) 50 60
90 110 130
180 225 kVA (IEC)
60 80
100 120 160
200
150/160
Galaxy 5000
kVA (UL) 40 50 60 80
100 130
kVA (IEC) 20 30 40 60 80
100 120
Galaxy PW
Galaxy VM 180kVA and 225kVA EARLY Release to
Quote November 5th, 2013 Manual process, local
price books, datasheets, and technical
collateral. Pre-Announcement January 3rd,
2014 Full Announcement February 3rd,
2014 Shipping February 2014
kVA (UL) 150 180 200
225 kVA (IEC) 160 200
Galaxy 7k
kVA (IEC) 160 200
8Galaxy VM Drivers
VM drivers
Features Multiple battery offers Redundant
fans 96 double conversion ECOnversion Full
front access Dedicated I/O(MBC) section Top /
Bottom entry Compact footprint
Customer values High availability
systems High efficiency system Easy to
deploy Safe solution
PLACE
9Galaxy VM Energy Star (Pending)
Target Certification BY EPA by February 2014
10Galaxy VM
Catalog
11Galaxy VM
Catalog
I/O Input/Output MBC Modular Battery
Cabinet CBC Classic Battery Cabinet BBB Battery
Breaker Box SBC System Bypass Cabinet
SBC
Note This is a phased product release These
items are part of the initial NAM release
12Catalog
UPS
Battery cabinets
Auxiliaries
180 - 225 Kva
Modular - Classical
GVMSBC450KG
System by-passes
Narrow
Unitary
GVMSBC675KG
GVMSB180KGS
GVMSBCLB675KG
GVMSB225KGS
GVMCBCABNE
GVMCBCABWE
GVMMODBCNS
Battery breaker boxes and kits
GVMRB180KGS GVMSB180KGS
Redundant 11 (Max)
GVMBBB600UL
GVMCBCWUE
Wide
GVMCBCWUE
GVMBBK250UL
GVMBBK400UL
GVMRB225KGS GVMSB225KGS
GVMCBC2WUF
Integrated parallel up to 4
GVMCBC2WUE
Others
GVMPB180KGS
GVMDFW-KIT
GVMPB225KGS
GVMMODBCWS
GVMCBC3WUF
GVMMBTU
13 Flexible Battery Offer 5 SKUS for
22 combinations
Catalog
Modular (Min)
- Classical
(Min)
180 kVA - 225 kVA
180 kVA - 225 kVA
7,4
5,1
1
5
19
14
2
GVMCBC2WUF
GVMCBCWUE
32
24
3
46
35
4
10
61
46
5
GVMCBC2WUE
GVMCBC2WUF
58
76
6
15
92
70
7
105
82
GVMCBC2WUE
GVMCBC3WUF
8
14Galaxy VM UPS - Product Design Benefits (1/2)
DC fans replaceable from front Allows very quick
fan replacement without going to bypass
- Power modules
- Unique slide in/out concept makes it quick to
replace by FSE
Bus bar connections in front Allows full
diagnostic of the system (current/ voltage
measurements) without opening into hazardous
voltages
Top and bottom cable entry The design allows
cabling from top and bottom and is included at no
additional cost
- Seismic IBC level 2 compliant
- Design elements included (floor anchoring only)
to be compliant with stringent seismic standard
Casters Allows for easy maneuverability
15Galaxy VM UPS - Product Design Benefits (2/2)
- Installation/ maintenance from front
- No rear access needed (can level system from
front). - No shadow footprint
- Network management
- Display is an NMC display. Ethernet and modbus
connection included in standard - 2 additional NMC cards can be added for enhanced
customer connectivity
- Separate Power and IO sections
- Power cabinet has all the complexity (which can
be fully isolated from IO) - IO cabinet has all the customer interfaces
regional specificity
- Dust filters
- Easy filter replacement (customer replaceable)
16Efficient solutionMonitoring for right decision.
Remotely all ranges solution
L o c a l l y
Remote monitoring service fast trouble
shooting Remote UPS ManagementNotification of
threatening situations Operating system shutdown
with PowerChute Network Shutdown
software Integrates into StruxureWare Central or
your preferred enterprise management system
7 color tactile display on all UPS Able to read
adjacent parallel UPS data
17An optimized architecture for all needs
Architectures
18 IP Parallel System using SBC
Architectures
- Parallel for capacity systems are bussed together
in a System Bypass Cabinet (a maintenance bypass
that permits landing of up to four modules) - Parallel modules are linked via a control cable
- System Bypass is equipped with system level power
monitoring - All paralleling intelligence is native to each
module - In the event of overload all module static
bypasses close at the same time. - There are no system level controls! Each module
is operated independently.
Up to 41 in parallel
1911 Redundant System
- Parallel for REDUNDANCY ONLY. 11 MAX
- Parallel modules are linked via a control cable
- No System Bypass Cabinet required
- All paralleling intelligence is native to each
module - In the event of overload all module static
bypasses close at the same time. - There are no system level controls! Each module
is operated independently.
Only one by-pass breaker
20 No Sync Box Required !
Architectures
Synchro information
Load 4
Load 3
No more synchro box
Load 2
Load 1
21Galaxy VM
- Service and safety
- Total power down of Power cabinet
- Full diagnostic from front with power on
- Green Burn in mode SPoT
- Advanced self test
- Quick swap fan replacement
- Service access form front only
- Modular battery and CBC drawer
- Fully tested power blocks
22Galaxy VM Modular Battery
- Value Modular Battery offer
- Quick swappable battery cartridges insuring fast
repair time - Up to 12 Strings within a single cabinet
- Easy replacement
- Redundancy at the string level
- Scalable back-up time
Modular battery cartridge
Narrow and wide modular battery cabinets
23Safe classical batterie offer wired from top or
bottom seismic compliant
Electrical
Architectures
Interfaces
Catalogue
VM drivers
Mechanical
Classical batteries configuration
Adjacent Only Wave I
Remote/Adjacent available as QSKU See price book
(Intrapack)
24Three Galaxy VM Battery Solutions
- Modular Battery Cabinet (MBC)
- Two different sizes Narrow and Wide
- Classic Battery Cabinet (CBC)
- Supports a classic battery solution
- Two different sizes Narrow and Wide
- Battery Breaker Box (BBB) supporting a rack
solution - Provides protection in installations with
customer-specific battery solutions
Images are not to scale
25Main performances
High Efficiency (Smart Capex and Opex) 41 in
parallel 40C and up to 50 C with a load
de-rating at 2,5 per C Eco mode and
ECOnversion mode with advanced SBS operation
- 480V Nominal
- 323V to 576V 40Hz to 70Hz
- Thdilt3
- (top bottom)
- Generator friendly
PF 0,9 Thdu 3 Overload 125 10 min 150 1
min
Seismic ready (IBC level 2) No side access and no
rear clearance required gt No shadow footprint
and Service from front only
High Capacity Charging Battery charging in
bypass operation
26Galaxy PW Retires after 12 years
- EOL July 2014
- Service Support thru July 2024
- Over 5000 units sold in NAM
27VM vs. PW
- Moved from Transformer Based to Transfomer-less
Topology - Increased efficiency from 93 to 96.2
- Reduced weight 3500 lbs to 1500 lbs
- THDI improved from 7 to 3
- No de-rating with lead power factor loads from
0.5 leading to 0.7 lagging - Reduced footprint with MBC by 50
- MBC external (not internal) but adjacent to UPS
48 with internal MBC 24 external MBC (95 of
Sales)
39 with Isolated MBC
28VM vs. PW continued
- Graphical display with build-in Network
Management - Three Operating Modes
- Now up to 5 modules in parallel
- Modular power assembly for fast repair time (3
minutes per BLOCK) - Hot Fan replacement (1 minute per fan)
- Top and Bottom cable entry without footprint
penalty - SPOT Self Test without load bank
Double conversion
ECO mode
ECOnversion mode
29225kVA with MBC 5 min battery
- PW is 150 Wide _at_12,500 lbs LIST 110,000
- VM is 68 Wide _at_4680 lbs LIST 95,450
30Galaxy VM Catalog (Price Book)
31Galaxy VM Catalog Configuration
- Available today in ES3 LIST PRICE BOOK
32(No Transcript)
33(No Transcript)
34Galaxy VM ISX Designer (Feb 3rd)