Access in Pediatric CRRT - PowerPoint PPT Presentation

1 / 21
About This Presentation
Title:

Access in Pediatric CRRT

Description:

Access If you don t have it you might as well go home. This is the most important aspect of CVVH therapy. Adequacy. Filter life. Increased blood loss. – PowerPoint PPT presentation

Number of Views:107
Avg rating:3.0/5.0
Slides: 22
Provided by: University802
Category:
Tags: crrt | access | cvvh | pediatric

less

Transcript and Presenter's Notes

Title: Access in Pediatric CRRT


1
Access in Pediatric CRRT
  • Patrick D Brophy MD
  • Pediatric Nephrology, Dialysis Transplantation
  • CS Mott Childrens Hospital
  • University of Michigan

2
The System is Down due to poor Access!
3
My first choice is.
4
Access
  • If you dont have it you might as well go home.
  • This is the most important aspect of CVVH
    therapy.
  • Adequacy.
  • Filter life.
  • Increased blood loss.
  • Staff satisfaction.

5
Vascular Access
  • Ideal Catheter Characteristics
  • Easy Insertion
  • Permits Adequate Blood Flow without Vessel Damage
  • Minimal Technical Flaws
  • High Recirculation Rate
  • Kinking
  • Shorter and Larger Catheters
  • SIZE DOES MATTER
  • Lower Resistance
  • Improved Bloodflow

6
Pediatric CRRT Vascular AccessPerformance
Blood Flow
  • Minimum 30 to 50 ml/min to minimize access and
    filter clotting
  • Maximum rate of 400 ml/min/1.73m2 or
  • 10-12 ml/kg/min in neonates and infants
  • 4-6 ml/kg/min in children
  • 2-4 ml/kg/min in adolescents

7
(No Transcript)
8
Venous Access for CRRT
  • Match catheter size to patient size and
    anatomical site
  • One dual- or triple-lumen or two single lumen
    uncuffed catheters
  • Sites
  • femoral
  • internal jugular
  • avoid sub-clavian vein if possible

9
Catheter Position
  • No Right or Wrong Choice of Placement
  • FACTORS
  • Clinical expertise
  • Body Habitus
  • Other catheters (Citrate anticoag-triple
    preferred)
  • Coagulopathy
  • Intra-abdominal distension

10
Catheter Position
  • Internal Jugular-Right- aim for RA to secure
    adequate BFR
  • Subclavian-Patient mobility? Most frequent site
    of inadequate performance -catheter curves and
    abutts against SVC-Vein collapses against
    catheter due to positional/volume change
  • Femoral- optimal position in tip of IVC

11
Vascular Access for Pediatric CRRT Pros and Cons
of Femoral Site
PROS
CONS
  • Relatively larger vessel may allow for
  • larger catheter
  • higher flows
  • Ease of placement
  • No risk of pneumothorax
  • Preserve potential future vessels for chronic HD
  • Shorter femoral catheters with increased
    recirculation
  • Poor performance in patients with
    ascites/increased abdominal pressure
  • Trauma to venous anastamosis site for future
    transplant

12
Vascular Access for Pediatric CRRT Pros and Cons
of IJ/SCV Site
PROS
CONS
  • Tip placement in right atrium decreases
    recirculation
  • Not affected by ascites
  • Preserve potential vein needed for transplant
  • SCV stenosis (SCV)
  • Superior vena cava syndrome
  • Risk of pneumothorax in patients with high PEEP
  • Trauma to veins needed potentially for future HD
    access

13
Femoral versus IJ catheter performance
  • 26 femoral
  • 19 gt 20 cm
  • 7 lt 20cm
  • 13 IJ
  • Qb 250 ml/min (ultrasound dilution)
  • Recirculation measurement by ultrasound dilution
    method

Little et al AJKD 361135-9, 2000
14
Femoral versus IJ catheter performance
Type Number Qb (ml/min) Recirculation() 95 CI
Femoral 26 237.1 13.1 7.6 to 18.6
gt 20cm 19 233.3 8.5 2.9 to 13.7
lt 20cm 7 247.5 26.3 17.1 to 35.5
Jugular 13 226.4 0.4 -0.1 to 1.0
plt0.001 plt0.007
Little et al AJKD 361135-9, 2000
15
Femoral versus IJ catheter performance
Pediatrics
P value NS NS NS NS
(Gardner et al, CRRT 1997Quinton 8 Fr n 20
120 Treatments)
16
Troubleshooting Access
  • How can you tell if you have a problem before
    starting?
  • Check placement first, then use syringe to test
    resistance and blood return.
  • What if you have problems during treatment?
  • Check line for kink, then assess patients
    position or need for sedation.

17
Access
  • Clotting or sluggish catheter.
  • tPA (tissue plasminogen activator).
  • (Spry et al.,
    DialysisTransplantation. Jan. 2001).
  • Normal saline flush.
  • Reason to replace catheter.
  • Clotted catheter with no response to tPA.
  • Exit site blood leakage with no response to
    pressure dressing.
  • Severe kinked catheter.
  • Bad re-circulation issues.

18
Pressures
  • Arterial or outflow pressures
  • High negative pressure access problem.
  • High positive pressure filter problem.
  • Moderate to high positive pressure high return
    (venous) pressure access problem.
  • Venous or return pressures
  • Moderate to high positive pressure high
    arterial pressure filter problem.
  • High return pressure moderate arterial pressure
    access

19
Vascular Access for Pediatric CRRTSome Final
Thoughts
  • Catheters with poor function will function
    poorly over and over and over and over
  • Balance between surgical/ICU expertise
    (preference?) and the necessary evils dictated by
    the patient
  • high PEEP femoral catheter?
  • massive ascites IJ catheter?
  • available sites are there any?
  • Which vessel are you willing to traumatize?

20
Conclusions
  • Poor Access-- May as well stop
  • Choice- patient size and optimal flows
  • Site- IJ/Femoral -recommended
  • Care- Local standard Lock issues- heparin
  • Troubleshooting- anticipate, what is the machine
    saying?
  • Happy Hemofiltering!

21
Thanks!
  • Stu Goldstein
  • Tim Bunchman
  • Theresa Mottes
  • Tim Kudelka
  • Betsy Adams
  • Tammy Kelly
  • Robin Nievaard
Write a Comment
User Comments (0)
About PowerShow.com