Danfoss presents- VLT 2800 Series
2
Product Range
  • 0.55 18.5 kW 3 phase380 - 480 V 10 50/60
    Hz
  • 0.37 - 1.5 kWCombined 1 and 3 phase200 - 240 V
    10 50/60 Hz
  • 2.2 - 3.7 kW3 phase200 - 240 V 10 50/60 Hz
  • Variable output frequency between 0 and 1000 Hz

3
Compact Size
  • Integrated product
  • Small size VLT 2803-2815
  • whd 75200168 mm3VLT 2822-2840
  • whd 90268168 mm3
  • VLT 2855-2875
  • whd 140268168 mm3VLT 2880-2882
  • whd 200505244 mm3
  • Mounting in 200 mm cabinet

4
User friendly
  • Built-on user interface
  • Full programmability from built-on user
    interface
  • Full text display available
  • Quick menu
  • User defined quick menu
  • Comprehensive documentation - Quick guide -
    Manual - Design guide

5
Programming
  • Fully programmable
  • from built-in display
  • Full text display avail-
  • able LCP2
  • Supported by VLT
  • Software Dialog MCT 10

6
Control Terminals
  • Built-in 24V10V supply
  • 5 Digital inputs - Fully programmable - Pulse
    input (0-65 kHz)
  • 2 Analogue inputs - Fully scaleable - 1
    Voltage input (0-10 V) - 1 Current input
    (0-20mA)
  • Analogue current output - Fully programmable
    - 0-20 mA or 4-20 mA
  • Relay output - Fully programmable - 250
    VAC / 2A - 500 VA
  • Sub-D connector for LCP
  • Serial communication
  • - Profibus/DeveceNet/Modbus RTU
  • - RS 485
  • Thermistor input

7
Automatic Motor Tuning
  • Perfect match between
  • motor and VLT
  • Measures the stator
  • resistance (R1)
  • Better shaft performance
  • Measurements done
  • without applying torque
  • Checks for missing
  • motor phases

8
Cold Plate
  • Reduced heating in cabinet
  • Denser installation
  • Higher enclosure class cabinets
  • Protection against
  • - Dust
  • - Dirt
  • - Humidity
  • Heat dissipates through the back of the drive

9
Flexible Mounting
  • Horizontal mounting
  • Vertical mounting
  • True side-by-side mounting
  • - No derating
  • - Also applies to modules
  • Temperature controlled fan

10
Temperature Depending Switch Frequency
  • Lowest possible motor
  • noise
  • Few inverter trips
  • Inverter protection

11
Braking Facilities
  • DC-braking
  • - Approximately 20 braking torque
  • AC-braking - Approximately 20 braking
    torque
  • Dynamic braking- Brake chopper built-in- 160
    braking torque
  • - Optional

12
Load Sharing
  • Energy savings
  • Common DC supply
  • Access to DC link

13
Process Closed Loop Control
  • Maintain a constant process value
  • - Temperature
  • - Pressure
  • - Level
  • - Speed
  • Fewer control components
  • Flexible feedback
  • - One current analogue input
  • - One voltage analogue input
  • - One pulse input (0-65 kHz)
  • All scaleable
  • Fully programmable PID controller

14
Precise Stop
  • Interrupt controlled stop
  • Higher process repeatability
  • Well defined stopping

15
Speed Compensated Stop
  • Better process control
  • Same stopping distance independent of initial
    motor speed

16
Counter Stop
  • Accurate positioning
  • High frequency input
  • (65 kHz)
  • 24V incremental encoder input
  • AB encoder input as option

17
Compliance with EMC Standards
  • Built-in EN 55011 1A filter, 25 m screened cable
  • No EMC disturbance
  • EN 55011 1B filter
  • available as module
  • IT mains compatible version with RFI filter (up
    to 4 kW)
  • VLT 2880-2882 withRFI-switch

18
Modules for improved performance
  • 1B Module- Increased RFI Protection
  • 1B/LC Module- Reduces acoustic
    motor noise
  • Motor coil module- Long motor cables 300 m

19
Reduced Harmonics
  • Less heating in installation components-
    Transformers, cables etc.
  • No disturbance of other equipment
  • Smaller cable dimensions
  • Reduced torque ripples from harmonics on mains
  • Built-in DC link chokes- In all 400 V units- In
    200 V 3 phase only units
  • Complies with IEC 61000-3-2

20
Galvanic Isolation
  • No need for extra safety precautions
  • Galvanic isolation between power and control
    section
  • Input terminals protected according to PELV

21
Product Safety
  • 100 short-circuit proof
  • 100 earth fault protection
  • Mains transient protection
  • Switching on input
  • Switching on output
  • Galvanic isolation
  • Designed according to EN 50178

22
Long Lasting Acquaintance
  • Designed for high reliability
  • Long life time
  • Self protecting frequency converter
  • All drives tested before shipment

23
Frequency Converter Specialists
  • Dedicated to frequency converter technology
  • Present in more than 100 countries
  • Global teams assist you in- Application-
    Engineering- Commissioning - Training-
    Service
  • 24 hour global service organisation