National Instruments LabVIEW box - PowerPoint PPT Presentation

1 / 2
About This Presentation
Title:

National Instruments LabVIEW box

Description:

Generalized tiebreaker wiring diagram National Instruments LabVIEW box USB 6501 COM microswitch NO When wiring to the microswitch, wire to the normally open (NO ... – PowerPoint PPT presentation

Number of Views:90
Avg rating:3.0/5.0
Slides: 3
Provided by: ignatz
Category:

less

Transcript and Presenter's Notes

Title: National Instruments LabVIEW box


1
Generalized tiebreaker wiring diagram
National Instruments LabVIEW box USB 6501
COM microswitch NO
When wiring to the microswitch, wire to the
normally open (NO) contact and to the common
(COM) contact. Polarity does not matter.
2
NI 6501 connections used
Pin No Tower Color
17 Yellow
18 Red
19 Blue
20 Green
25 Common
NI 6501 pin outs
Wiring is run from the microswitch to the back of
the switch standoff, down the base rack mount to
the hole in the base beam. Wire is stapled in
place along standoff and base rack. Wire runs
through the hole to the channel, where it is
directed to the desired end of the tower
assembly and to the NI box which is collocated
with the scoring PC. Any small gauge wire can be
used. Least expensive is option is probably one
pair from an unbundled cat 5 cable for each
switch.