Title: Intermec Solutions for Hazardous Environments: CK32IS
1Intermec Solutions for Hazardous Environments
CK32IS
2Global Considerations
- Global Certification requirements
UL (Underwriters Laboratory)
ATEX (European Atmospheres Explosibles Directives)
IEC (International Electrotechnical Commission)
Australia Singapore Malaysia Philippines Indonesi
a Saudi Arabia
European Union Norway Switzerland Turkey
U.S. Canada Mexico
Austria Belgium Bulgaria Cyprus Czech
Republic Denmark Estonia Finland
France Germany Greece Hungary Ireland Italy
Latvia Lithuania Luxembourg Malta Netherlands
Poland Portugal Romania Slovakia Slovenia
Spain Sweden United Kingdom of Great Britain
and Northern Ireland
3Global Reach
- Hazardous Environment Certifications
- UL, ATEX, IEC
- Localized Languages
- English, Spanish, French, German, Italian,
Simplified Chinese, Traditional Chinese, - Korean, Thai (character set only)
- RoHS Compliance
- Restriction of the Use of Certain Hazardous
Substance in Electrical and Electronic - Equipment
- WEEE Compliance
- Waste Electrical and Electronic Equipment
- RF Certifications
- Support Service
- Certified repairs at all service centers worldwide
4Hazardous Certifications
UL (Underwriters Laboratory)
ATEX (European Atmospheres Explosibles Directives)
IEC (International Electrotechnical Commission)
Gases, Liquids, Vapors
Gases, Liquids, Vapors
Gases, Liquids, Vapors
Class I Division 1 Group A,B,C,D (T4) Class 1
Zone 0 Group IIC (T4)
Zone 0 (T4) Group IIC
Zone 0 (T4) Group IIC
Dusts Fibers
Dusts Fibers
Dusts Fibers
Class II Division 1 Groups E, F and G
Zone 20 Group II T250C
Zone 20 Group II T250C
Class III Division 1
Underground Mining
Underground Mining
Group I M1
Group I M1
Except conductive dust
5Hazardous Certifications
- From concept, design specifications dedicated to
meeting customers most stringent requirements
for flammable gases, vapors, liquids, dusts or
fibers.
UL (Underwriters Laboratory)
ATEX (European Atmospheres Explosibles Directives)
IEC (International Electrotechnical Commission)
Gases, Liquids, Vapors
Gases, Liquids, Vapors
Gases, Liquids, Vapors
Class I Division 1 Group A,B,C,D (T4) Class 1
Zone 0 Group IIC (T4)
Zone 0 (T4) Group IIC
Zone 0 (T4) Group IIC
Dusts Fibers
Dusts Fibers
Dusts Fibers
Class II Division 1 Groups E, F and G
Zone 20 Group II T250C
Zone 20 Group II T250C
Class III Division 1
Underground Mining
Underground Mining
Group I M1
Group I M1
Except conductive dust
6High Level Device Requirements
- Chemical, Oil Gas, and Pharmaceutical
- customers told us their ideal requirements
- One Device - Globally
- One Manufacturer - Globally
- Long Product Life Cycle
- Industry Commitment - Globally
- Global Technical Support Service
7Detailed Device Requirements Typical Customer
- Device Windows mobile PDA
- Hazardous Ratings
- 60 - UL Class 1 Div 2 for North America
- 5 - UL Class 1 Div 1 for North America
- 20 - ATEX Zone 2 for Europe
- 5 - ATEX Zone 1 for Europe
- 10 - IEC, Rest of World (RoW)
- Memory
- 128 MB of RAM / 512 MB of Flash Storage
- Communications
- 802.11b/g
- Cisco CCX V3 radio support
- Bluetooth Used to talk to peripherals (RFID,
Vibration, Temperature probes) - Keyboard/Ergonomics
- Big, easy to use Arrows Numeric Keys (for use
in gloved environments) - User installable Trigger Handle
- Support
- 8 Hours of Battery Life
- No loss of data/application after cold boot
8Detailed Device Requirements What are yours?
- Device?
- Hazardous Ratings?
- Memory?
- Communications?
- Keyboard/Ergonomics?
- Support?
9Enterprise Asset Management Solutions
- Example Plant Maintenance Repair
- Trend
- Good maintenance and support practices are an
- integral component of optimized production
processes - and lean manufacturing.
- Key Issues
- Manufacturers are focused on improving the
efficiency - of production.
- As production capacity rises above 80
utilization, - efficiency and productivity in plant
maintenance and repair is mandatory. - Return on Assets (ROA) is becoming the primary
driver - of equipment investment.
- Solutions
- In-premise and extra-premise predictive
maintenance. - Break-Fix operations.
- Dispatching for optimized production.
- Operator directed response (ODR).
10Intermec Hazardous Environment Solutions
751 Class I Div 2
751 ATEX Zone 2
730 Class I Div 1
CK31 Class I Div 2
CK61 Class I Div 2
CK32IS
11Intermec Hazardous Environment Solutions
751 Class 1 Div 2
751 ATEX Zone 2
730 Class 1 Div 1
CK31 Class 1 Div 2
CK61 Class1 Div 2
CK32IS
Intermec Solutions Family
Scanners
Printers
Mobile Computers Fixed Mount Computers
RFID
12CK32 Intrinsically Safe Mobile Computer
13CK32IS Features
Windows Mobile 5.0 Premium Phone Edition MSFP
802.11b/g WLAN w/ CCX 3, USB Bluetooth Ethernet
Intel XScale PXA270 Processor
Intermec Linear Imager
QVGA Color Display w/ Touchscreen
42 or 56 Keypad options (Standard, 3270/5250,
VT/ANSI)
128 MB RAM 512 MB Persistent Storage
Integrated Speaker/microphone
14CK32IS Usability
- User installable trigger handle
- Batteries removable in hazardous environments
- Keypad options support gloved use
15CK32IS Accessories
- Communication Adapter
- USB Client and Ethernet
- Battery Eliminator
- Battery Pack Option
- Quad Battery Charger
- Trigger Handle
- User Installable
- Carrying Strap
- Leather
- Hand Strap
- Screen Protector Kit
- Tethered Stylus Kit
Associated Apparatus Certified Guarantees
that any outside equipment cannot damage the
unit. Not for use in Hazardous environments.
16CK32IS Durability
- Designed from inception for exceptional
durability - 5 foot drop specification
- IP67 sealed
- Operating temperature -20C to 50C
- Robust construction
- Electrostatic Dissipation
- Internal Antennas
- Hard Plastic Key tops
- Polycarbonate Enclosure
- Internal Magnesium Frame
- Internal Shock Mounting
- Encapsulated Circuit Boards
17Hardware Durability
- Internal Magnesium Frame
- Thicker than comparable frame in standard product
- Lightweight but strong
- Internal skeleton
18Hardware Durability
- Magnesium frame
- Reduces flexing, risk of damage
- Maintains relative alignment and spacing
- Protects LCD display glass
19Hardware Durability
- Encapsulated Circuit Boards
- High temperature silicon for thermal insulation
- Second line of protection against gas dust
- Protects components from shock, vibration,
corrosion
20Hardware Durability
- Internal Shock Mounting
- Isolates electronic modules
- Display
21Hardware Durability
- Hard Plastic Key Caps
- Laser engraved
- Silicon Keypad
- Touch Screen
- Touch Screen Protector
22Hardware Durability
- Polycarbonate Enclosure
- Extra thick, high quality, reinforced
- Conductive
- IP67-rated seal
- Modular construction
23Worldwide Service Support
- Medallion service contracts
- Tel and web based post sales support
- More than 70 service support facilities
- Local languages, time zones
Intermec Repair Locations Intermec Global Service
Partners
24CK32IS Hazardous Certifications
- Certified Intrinsically Safe by ALL 3 global
agencies, for gases, vapors, liquids, dusts,
fibers and underground mining. - Todays safety requirements. And tomorrows.
UL (Underwriters Laboratory)
ATEX (European Atmospheres Explosibles Directives)
IEC (International Electrotechnical Commission)
Gases, Liquids, Vapors
Gases, Liquids, Vapors
Gases, Liquids, Vapors
Class I Division 1 Group A,B,C,D (T4) Class 1
Zone 0 Group IIC (T4)
Zone 0 (T4) Group IIC
Zone 0 (T4) Group IIC
Dusts Fibers
Dusts Fibers
Dusts Fibers
Class II Division 1 Groups E, F and G
Zone 20 Group II T250C
Zone 20 Group II T250C
Class III Division 1
Underground Mining
Underground Mining
Group I M1
Group I M1
Except conductive dust
25Designed to Deliver Highest Level of Safety
- Full International Safety Certifications in One
Computer - Meets or Exceeds Latest Safety Standards Zone 0
- Exceptionally Rugged 5 drop, IP67
- Worldwide Service Support
26Next Steps
- Compliance
- Define your safety certification
- requirements
- Configuration
- Determine detailed device
- requirements
- Service Support
- Determine global needs
27Thank you!
ADC Nordic - Distributor in the Nordic
countries Phone 46 40-680 02 80