700 series training - PowerPoint PPT Presentation

1 / 22
About This Presentation
Title:

700 series training

Description:

700 Series Self Diagnostic Intelligent Detector Range 700 Series Increasing the Overall Integrity of the System Preventing False Alarms Maintenance Friendly ... – PowerPoint PPT presentation

Number of Views:37
Avg rating:3.0/5.0
Slides: 23
Provided by: jdb96
Category:

less

Transcript and Presenter's Notes

Title: 700 series training


1
More Than Technology...
2
  • 700 Series
  • Self Diagnostic
  • Intelligent
  • Detector Range

3
700 Series Optical
4
700 Series Heat - R.o.R
5
700 Series
  • Increasing the Overall Integrity
  • of the System
  • Preventing False Alarms
  • Maintenance Friendly
  • Guaranteeing Optimum Detection
  • Installer - User Friendly

6
Preventing False Alarms
  • Automatic Self Diagnostics
  • Manual Self Diagnostics

Industry First
7
Automatic Self Diagnostics
8
Preventing False Alarms
  • Automatic Self Diagnostics
  • Full dynamic detector test every 24 hrs.
  • Detector fault sensitivity drift signaling by
    flashing trouble LED

Industry First
9
Preventing False Alarms
  • Automatic Self Diagnostics
  • Built in drift compensation
  • Floating back ground
  • Sensitivity adjustment

Industry First
10
Drift Compensation
700 SERIES DETECTOR
STANDARD DETECTOR
TIME
11
Drift Compensation
  • 2X Doubles 2X
  • True Operational Life Time
  • Of The
  • Detectors

12
Panel Signaling
- coded signal back to panel - indication per
zone - all detectors remain operational
13
Manual Self Diagnostics
14
Manual Self Diagnostics
  • Number of blinks indicates
  • detector status
  • 1 non serviceable hardware fault
  • 2 - 3 detector too insensitive
  • 4 - 7 detector within sensitivity limits
  • 8 - 9 detector too sensitive

15
Manual Self Diagnostics
  • No need for external meters or sophisticated test
    tools
  • Easy field test with magnet

16
Maintenance Friendly
Field Exchangeable Optical Chamber
Industry
First
17
Optical Block - Labyrinth
18
Field Exchangeable Optical Block
  • Field Maintenance
  • Where needed, When needed
  • On site cleaning
  • Reduced Maintenance Cost
  • No need for exchange pool
  • Disposable optical chamber
  • Increased Reliability
  • Fast and easy intervention

19
Installer User Friendly
  • Operates from 8.5 - 33 Vdc
  • Polarity independent
  • Dual LED fire - fault
  • With or without relay
  • On board relay
  • Range optical/heat-r.o.r
  • Multi criteria - multi sensor

20
Multi Criteria Detector
21
Multi Criteria Detector
  • Fast response optical/heat detector
  • Interactive optical/heat algorithm
  • Rapid response to both smouldering and flaming
    fires
  • Latching and non-latching relay version

22
700 Series
Excellence At Work
Write a Comment
User Comments (0)
About PowerShow.com