Photogrammetry Review - PowerPoint PPT Presentation

About This Presentation
Title:

Photogrammetry Review

Description:

... Cryostat) Specifics of Aicon System Reverse Engineering Deflection analysis Import/export pre/post processing How to avoid Wendelstein processing time ... – PowerPoint PPT presentation

Number of Views:93
Avg rating:3.0/5.0
Slides: 6
Provided by: mvi55
Learn more at: https://ncsx.pppl.gov
Category:

less

Transcript and Presenter's Notes

Title: Photogrammetry Review


1
Photogrammetry Review
  • Raphael Goudard Visit
  • Nov 27 Nov 30

2
Suggested Activities
  • Intro to NCSX Project / Assembly Sequence
  • Brown movies and models
  • Photogrammetry use on current phase
  • Measure and compare to our files
  • Offer suggestion of how photogrammetry can be
    used to rack and align coils
  • Photogrammetry use on future phase
  • MCHP (3 coil Half Period), FP (Field period) and
    final assembly
  • Lock in on machine as we assemble layers (Mod
    coils, TF coils, PF Coils, Cryostat)
  • Specifics of Aicon System
  • Reverse Engineering
  • Deflection analysis
  • Import/export
  • pre/post processing
  • How to avoid Wendelstein processing time (when
    does it bog down)
  • Reuse of coded target numbers
  • Is he familiar with GSI V-Star system?

3
Debrief
  • Arrived Monday gave brief tour
  • Tuesday Set up targets on A1 930 1030 Took
    a lot of time to ream holes for new
    photogrammetry targets
  • 1030 1130 took first project set of 200
    pictures Verify A1 scan with laser tracker (.060
    mm)
  • Placed B1 on A1 then took second set of 200
    photos and learned that B1 did not distort A1.
    (.070 mm)
  • During lunch B1 was removed then took third set
    of photos after lunch and verified the A1 still
    was stable (.060 mm)

4
Debrief
  • Wednesday Set up targets on B3 which had just
    completed racking and measuring
  • Took pictures to characterize coil (.050 mm)
  • Unracked coil using dial indicators took photos
    and whiskers showed that coil moved exactly as
    dial indicators.
  • Analyzed data using best fit as well deformation
    analysis (.090 mm)
  • Realigned wedge to itself before and after and
    could identify deformation vs. translation (.180
    mm)
  • We then tried to rerack the coil by restoring the
    dial indicators.
  • The detection of this movement was much easier
    and obvious with photogrammetry
  • We validated this movement by checking a couple
    of point with the laser tracker.

5
Debrief
  • Thursday Validated LT measurements and Steve
    operated software personally and reran Mondays
    data from the beginning to the end.
  • Photogrammetry has validated that the laser
    tracker measurements to date are valid. Best
    fits of Photogrammetry to LT are within (.060 mm)
Write a Comment
User Comments (0)
About PowerShow.com