Wood LRFD Seminar - PowerPoint PPT Presentation

About This Presentation
Title:

Wood LRFD Seminar

Description:

SW2 diaphragm 1 diaphragm 2 C1 SW1 Boundary occurs at interior shear walls! R1L R2R R1R R2L Field condition that must be boundary nailed! Roof Layout v1R – PowerPoint PPT presentation

Number of Views:54
Avg rating:3.0/5.0
Slides: 3
Provided by: John906
Category:
Tags: lrfd | seminar | shear | walls | wood

less

Transcript and Presenter's Notes

Title: Wood LRFD Seminar


1
w (plf)
SW2
diaphragm 1
diaphragm 2
C1
SW1
Boundary occurs at interior shear walls!
R1L
R2R
R1R
R2L
Field condition that must be boundary nailed!
Roof Layout
v1R
v1L
v2L
v2R
Roof Shear Diagram
2
w 400 plf
Roof sheathing 15/32 CDX wood structural panel
with 2x framing and 8d nailing
32
Continuous panel joint
56
R 11,200
R 11,200
8
8
24
8
8
v350 plf
v250 plf
v150 plf
Roof Shear Diagram
v150 plf
v250 plf
v350 plf
8d _at_4/6/12 fully blocked
8d _at_6/6/12 fully blocked
8d _at_6/6/12 fully blocked
8d _at_4/6/12 fully blocked
8d _at_6/12 unblocked
Roof NailingZones
What does 8d _at_4/6/12 mean? Please refer to
Table 23-II-H
Write a Comment
User Comments (0)