Title: Electricity Quantity
1ElectricityQuantity Quality
Hervé Mougeot
2Market Overview
Quantity Quality Safety
- Quantity Allocate energy usage, detailed cost
analysis, cut energy costs, negotiate better
energy contracts, demand control and peak saving,
information for improving infrastructure, load
curtailment and price response, power factor
correction. - Quality Availability, troubleshooting,
productivity, preventive maintenance, quality
statistics, information for improving
infrastructure - Safety protect people and property
Quality
UZ I
Quantity
Safety
3Electrical Network
Production Transmission Distribution Users
LV
HV
MV
Network Share of the electricity ... and the
pollution. Example The pollution generated
from a disturbing load will be distributed to the
neighbors more or less attenuated depending on
the network impedance.
4ElectroMagnetic Compatibility
Immunity secured load
Immunity standard load
Disturbance level
EN50160
Compatibility
Emission on the network
Emission from single load
IEC1000-3-x
t
5ElectroMagnetic Compatibility
6Compatibility
Transient
Swell
Dip
73 Phases System
U31
V3
U23
V1
V2
U12
8Electrical Disturbances
low frequency, conducted
- Voltage variations
- Voltage Dips
- Interruptions
- Voltage Swells
- Flicker
- Harmonics
- Inter harmonics
- Transients
- Frequency
- Unbalance
- Amplitude
- Wave Shape
- Frequency
- Symmetry
9Voltage Variations
10Voltage Dips
11Interruptions
100
12Dips, Swells and Interruptions
13Flicker
14Flicker
Pst 1 , cas des variations rectangulaires
15Harmonics
16Harmonics
17Transients
18Unbalance
19Frequency Variation
20Disturbances
Dips, Swell, Interruptions
Flicker
Harmonics
Transients
Frequency Variation
Unbalance
21Parameters
Parameters Value Limits
Urms LV 230V / 400V 10 / -10
Urms MV 20kV 7 / -7
Frequency 50 Hz 2 / -2
Wave shape Sinusoidal THD lt 8 en BTA
Symmetry U U1U2U3 2
22What to measureEN 50160Voltage characteristics
in public distribution systems
23EN 50160 Parameters
- Voltage Variations
- Flicker Pst/Plt
- Harmonics order 2 to 25, THD (40)
- Signalling (ripple control) voltages
- Frequency
- Unbalance
- Voltage dips and swells
- Interruptions
Measurement over 1 week
24EN 50 160 - Limits
25EN 50 160 - Data
26To measure according EN 50 160 150.000 data
to analyze
- for 1 week, for 1 point !
27To analyze according EN 50 160 1 second with
DRANETZ BMI
2890 curves to analyze
29Compression of the information
30(No Transcript)
31Amplitude
standard
95
100
number of measuring values
32Amplitude
standard
95
100
number of measuring values
33Amplitude
standard
95
100
number of measuring values
34Amplitude
standard
95
100
number of measuring values
35Overview about the Power Quality
36How to measureIEC 61000-4-30 Testing and
measurement techniques Power Quality
measurement methods
37Measurement techniques
Continuity / Change
38Permanent / Trigger
39Events / Trend
8
256 s/c 16-Bit
T
A/D
FIFO
(4)
T
Transient
1 MHz 12-Bit
X
40Measurement methods
41Event recording
Acquisition Treatment Characterization
Detection Evaluation Classification
Measure Analyze Archive
Recording
42(No Transcript)
43Long term recording
44(No Transcript)
45Zero Crossing of Fundamental (filtered)
10
150
Synchronised Clock 20msec
10min
2h
46(No Transcript)
47(No Transcript)
48(No Transcript)
49(No Transcript)
50(No Transcript)
51(No Transcript)
52(No Transcript)
53YES ?
NO ?
54(No Transcript)
55Where to measure Compliance / Trouble shouting
56Amplitude
Transient
User
Network
Swells
Flicker
Dips
Momentary Temporary Long Duration
Instantaneous
Interruptions
Duration
57Measuring point
Statistics / Diagnostic
58Multi-sites monitoring
59Multi-sites monitoring
- A lot of data
- To transmit
- To analyze
60Analysis
61Embedded analysis
62How to analyze Overview / Details
63Overview
64Overview
65Trends
66Trends
67Overview
68Events
69Classification
70Details
71Key points
- To measure ALL the parameters at the same time
through differential inputs - To measure according IEC 61000-4-30 class A
- Adapted trigger mode
- Easy to configure
- Automatic overview
72Complete solution