Phase Noise and Noise Measurement - PowerPoint PPT Presentation

About This Presentation
Title:

Phase Noise and Noise Measurement

Description:

Title: Introduction to High Frequency Structure Simulator Author: jiapc Last modified by: Scully Created Date: 7/24/2001 6:50:44 AM Document presentation format – PowerPoint PPT presentation

Number of Views:131
Avg rating:3.0/5.0
Slides: 24
Provided by: jia61
Learn more at: http://my.ece.ucsb.edu
Category:

less

Transcript and Presenter's Notes

Title: Phase Noise and Noise Measurement


1
Phase Noise and Noise Measurement
  • Pengcheng Jia
  • Nov 21, 2002

2
  • Phase Noise

3
Sth New
  • Phase Noise Measurement with PSA (precision
    spectrum analyzer)
  • Mode-gtPhase Noise-gtLogPlot
  • But pay attention to noise floor of the PSA. You
    can use noise floor cancellation function or use
    the HP11848 Phase noise system

4
Phase Noise Origins
  • 1/f Noise of Semiconductor Transistor
  • DC Bias related noise (Shot Noise)
  • Thermal Noise from Resistors

5
Phase Noise Basic
6
Residual Noise Measurement
20 dB Attenuator
11848 Phase Noise Interface
8dBm
R Port
L Port
10dBm
GPIB Control

0.01Hz 100KHz
3561A Dynamic Signal Analyzer
  • Phase shifter is used to achieve quadrature
  • Attenuator is used to keep input power at
    required level
  • Phase noise of source will not affect residual
    noise of DUT when quadrature is achieved

7
3048 System
11729
11848
3561
Spectrum Analyzer
8
Phase Noise Measurements
Phase Noise without amplifiers
Phase noise of a broadband amplifier
9
3048A Phase Noise Software
  • Tiger is the 3048A system controller
  • Start in MS-Dos Mode
  • At the command prompt, enter c\go
  • Select 13 as the printer type and 0 as the screen
    mode. The other settings are user preference
  • Now you are at c\noise\3048gt
  • Run cal.exe for calibration and PN.exe for
    measurement

10
Instrument Addresses
  • Run PN.exe, Main Menu-gtSystem-gtInstrument
  • Instrument Model Address
  • FFT Analyzer 3561A 712
  • RF Analyzer 8567A 718 (optional for offset from
    100K to 40MHz)
  • Signal Srce 1
  • Signal Srce 2
  • Down Converter 11729C 706 (optional)

11
Getting system ready
  • Functional Checks
  • Quick Check
  • Performance checks
  • Calibrations
  • Read appendix for the time and sequence of
    calibration

12
Run PN.exe
  • 1.Type of measurement-gtPhase noise without using
    PLL (for residual phase noise measurement)
  • Start/Stop frequency are the offset frequency
    from the carrier
  • 2. Parameters
  • Input carrier frequency and select detector

13
Continue
  • Instrument control
  • Select system connections
  • Define graph
  • Configure the displayed graph
  • System configuration-gtInstruments
    addresses-gtInput addresses

14
File System
  • Test file Directory
  • Save all the configurations for the measurement
  • Result file directory
  • Save the measurement result in this directory
  • Always choose this directory before you save
    your result, otherwise you only save the
    configurations, not the data!!!
  • Run Read_res.exe to convert .res file to data
    file which can be used in graph tools.
  • Go to mishrayork web-gtdocument for the file.

15
Calibration-theory
16
Calibration-operation
  • For the first time, run calibration
  • Select Derive from measured beat tone
  • -gtexit to main menu-gtNew measurement
    -gtY-gtSelect 1KHz as beat-tone (range from 1Hz
    to 50KHz), input the beat tone signals to the R
    and L input of the 11848 interface-gtProceed-gtget
    detector constant
  • Then change connection back and measure PN
  • Next time, go to calibration-gtuse current
    detector constant

17
Measurement
  • Pay attention to the right and left channel power
    level
  • For frequency 1.2 G to 18G
  • L 7-gt10dBm
  • R 0-gt10dBm
  • Keep R channel close to 10dBm, the higher R
    signal, the lower noise floor

18
  • Noise Figure

19
Measurement System
Noise Figure Meter-8970B
Noise Source Driver
CW Generator-8673G Output power-8dBm
Noise Source - 346C
Noise Input
LO Signal Input
Test Set-8971B Working ModeSSB3 From
4-18GHz Down Convert to 450MHz Single Side Band
Noise
20
Single MMIC Measurement
Bias For MMIC
Microstrip Probe
Noise Output
Noise Input
MMIC
21
Combiner Measurement
Bias For MMICs
Noise Source Driver Input
Noise Input
Noise Source
Noise Output
Power Combiner
Heat Sink
22
Measurement Theory
  • The Noise Figure Meter output noise at two
    different noise temperature
  • Get the G and Na from the measurement
  • Calibrate to eliminate the affect of the loss of
    the cable and connectors

Output Noise Power No
N2
N1
Na
Noise Temperature-T
T1
T2
23
Measurement Result
Write a Comment
User Comments (0)
About PowerShow.com