Title: Wind Tunnel Specifications
1Wind Tunnel Specifications
- 50kW synchronous AC motor, centrifugal fan
- Vertical diffuser, area ratio 2.87
- Horizontal diffuser, area ratio 2.65
- Settling chamber 2650 x 2150 x 2500mm length
- Contraction, area ratio 11.4
- Working section, 1000x500mm outlet, open sided
- Four plastic screens (open area ratio 0.65) fixed
in the fan adaptor and diffuser sections - Aluminium Honeycomb in the settling chamber,
50.8mm thickness, 6.3mm cell size
2Flow Uniformity
5 m/s
10 m/s
15 m/s
- Flow velocity contours at tunnel outlet without
working section
3Flow Uniformity
Velocity contours in working section
5 m/s
10 m/s
- Flow velocity is within 1 of mean velocity
across the 1m x 0.5m working section outlet
4Horizontal Wind Gradient
- Mean pressures A B measured simultaneously with
two pitot-static tubes spanning 200mm at the
anemometer cup location. Procedure repeated with
p-s tubes reversed. - Linear regression shows 0.3 difference in
pressure
5Turbulence Measurements
single normal hotwire
Pitot-static tube (design similar to AMCA type)
anemometer filter (5kHz)
Pressure Transducer Ashcroft XLdp
Analog-Digital Converter NI PCI-6013 (16 bit)
PC
6Turbulence Intensity
Turbulence Intensity
Mean Velocity (m/s) Turbulence Intensity ()
4.01 0.19
8.07 0.30
12.20 0.44
16.16 0.38
7Wind Tunnel Turbulence Spectra
8Cup Anemometer Calibration Setup
9Calibration Procedure
Pitot-static tube (design similar to AMCA type)
Pressure Transducer Ashcroft XLdp
HP Frequency Counter
Analog-Digital Converter NI PCI-6013 (16 bit)
PC
- Risoe P2546A cup anemometer calibrated using the
Measnet procedure - No blockage included for Newcastle result
Slope Offset Correlation coefficient
Newcastle 0.6267 0.2668 0.999989
DEWI 0.6267 0.248 0.999992