Transcript and Presenter's Notes

Title: Technical Updates on UTEVA, TEVA and TRU Resins


1
Technical Updates on UTEVA, TEVA and TRU Resins
Anil Thakkar Michael Fern Eichrom Technologies,
Inc. Paris May 14, 2002
2
Topics
  • UTEVA Resin
  • Decontamination of Po-210
  • U-232 yields
  • TEVA Resin
  • Decontamination of U-nat/Th in Tc-99 region
  • TRU Resin
  • Am recoveries

3
U-232 Yields
  • Unrealistic high U-232 yields reported with UTEVA
    resin in samples with high in Pb-210

4
Current Procedure
  • 1) Load sample on UTEVA resin with 10 ml of 3M
    HNO3/1M Al(NO3)3. with 2 mL of 0.6M Ferrous
    sulfamate and 200 mg of ascorbic acid.
  • 2) Rinse sample beaker with 5 mL of 3M HNO3
  • 3) Rinse column with 5 mL of 3M HNO3
  • 4) Rinse column with 5 mL of 9M HCl
  • 5) Rinse column with 20 mL of 5M HCl/0.05M Oxalic
  • 6) Elute U with 15 mL of 0.01M HCl

5
Effect of Ferrous210Pb/210Po spike (1100 pCi)
6
Effect of Additional 3M HNO3 Rinse 210Pb/210Po
spike
7
(No Transcript)
8
Effect of Uranium Strip Solution no ferrous
added 210Pb/210Po spike (1100 pCi)
9
Additional Rinse/1M HCl Strip Combo
10
Revised Procedure
  • 1) Load sample on UTEVA with 10 ml of 3M HNO3/1M
    Al(N03)3 with 2 mL of 0.6M Ferrous sulfamate and
    200 mg of ascorbic acid
  • 2) Rinse sample beaker with 5 mL of 3M HNO3
  • 3) Rinse column with 5 mL of 3M HNO3
  • 4) Rinse column with 10 mL of 3M HNO3 (3x)
  • 5) Rinse column with 5 mL of 9M HCl
  • 6) Rinse column with 20 mL of 5M HCl/0.05M Oxalic
  • 7) Elute U with 15 mL of 1M HCl

11
Summary
  • A good decontamination of Po-210 in U-232 region
    can be achieved by additional 3M HNO3 rinse on
    UTEVA and eluting uranium selectively with 1M HCl

12
TEVA Column Tc-99 Issues
  • Problem reported by Darrin Mann (BWXT, Oak Ridge,
    Tn) with bias high Tc-99 recoveries in samples
    with natural uranium.
  • Th-234 interference was detected in Tc-99 region.

13
BWXTs Tc-99 Procedure
  • Solid samples are digested and dissolved finally
    in 20 ml of 0.1M HNO3
  • Load sample on TEVA column
  • Rinse column with 25 ml of 0.1M HNO3
  • Extrude resin from the column in a LSC vial.
  • Add cocktail and count on LSC.

14
BWXTs Procedure tested at Eichrom
  • Spiked 20 ml of 0.01M HNO3 with 2000 dpm of
    U-234/238
  • Load on TEVA Resin column
  • Rinse with 25 ml of 0.1M HNO3
  • Extrude resin in LSC vial
  • Added 15 ml of cocktail and count

15
Possible Solutions for Decontamination
  • Use of fluoride to complex the residual Th-234 on
    the column
  • Two fluoride solutions tested
  • Hydrofluoric acid
  • Sodium fluoride

16
Decontamination of Th-234
  • Spiked 20 ml of 0.01HNO3 with 2000 dpm of
    U-234/238
  • Load on TEVA Resin column
  • Rinse with 5 ml of 0.1M HNO3
  • Rinse with 25 ml of 0.5M HF/0.02M HNO3 OR with
    25 ml of 1M NaF/0.02 HNO3
  • Rinse with 5 ml of 0.1M HNO3
  • Extrude resin in LSC vial
  • Added 15 ml of cocktail and count

17
BWXTs ProcedureTest ResultsRinse volume
used25 mL
18
Conclusion
  • Decontamination of Th-234 in Tc-99 region can be
    accomplished with additional fluoride rinse on
    the TEVA Resin columns
  • Fluoride in the form of 1M NaF or 0.5M HF
    solutions could be used to remove the residual
    amounts of Th-234

19
TRU Resin History
  • Historical problems with Am recoveries from TRU
    Resin (HCl strip.)
  • Suspected Extractant Leaching handled with wet
    ashing of HCl Strip Solution

20
TRU Resin Cartridges
1) TRU Resin 2) TRU Resin with a post
Prefilter layer
21
Am-243 Spike Test
1) Spike 10 ml of 3M HNO3 with 6.52 dpm of
Am-243 2) Load solution on TRU cartridges
(assisted with VBS, flow rate 1ml/min) 3) Rinse
with 10 ml of 3M HNO3 4) Rinse with 5ml of 0.5M
HNO3 5) Strip Am with 9M 4M HCl
22
Cerium Fluoride Precipitation
  • Four different preparation prior to CeF3 ppt.
  • 1) Digested with Aqua-regia
  • 2) Undigested
  • 3) Changed molarity (0.5 M HCl)
  • 4) Digested with 10 H2SO4

23
Am-243 recoveries (n4)
24
RETEST Am-243 recoveries (n4)
25
ACW03 tested for Am
  • 0.5 L of Eichrom tap water spiked with Am-243
  • Precipitated Am with calcium phosphate
  • Scavenge ppt. and dissolve in the load solution
  • Followed ACW03 procedure using UTEVA/TRU
    cartridges
  • Collect Am fraction

26
ACW03continued
6) Evaporate Am fraction to dryness 7) Add 0.5 ml
of conc. HCl and dilute to 15 ml of DI water 8)
Perform CeF3 ppt.
27
Tap Water Am-243 recoveries(n5)
28
Conclusion
  • Am recoveries improved by changing the
    concentration on HCl prior to CeF3
  • TRU resin cartridge performed well once the HCl
    concentration was changed
Write a Comment