The special unit for special tasks - PowerPoint PPT Presentation

1 / 23
About This Presentation
Title:

The special unit for special tasks

Description:

... (sensor) cable Seismic sensor (optional) Frequency detector (not used) PIR sensor ... The more sensor cable applied to a given section of fence ... – PowerPoint PPT presentation

Number of Views:212
Avg rating:3.0/5.0
Slides: 24
Provided by: K267
Category:
Tags: sensor | special | tasks | unit

less

Transcript and Presenter's Notes

Title: The special unit for special tasks


1
The special unit for special tasks
2
  • Installation possibilities

3
Technical specifications
  • Power supply voltage 9-36 Vdc
  • Current 200 mA
  • 4 freely-configurable input channels
  • 4 NC relay outputs
  • Remote outputs testing
  • 250m sensor cable/input (max.)
  • Starting point is extendable (max. 500m) using
  • DC (non-sensitive) cable
  • Radio interference- resistant metal housing
  • (IP65-rated)
  • Programming via computer (RS485 protocol)
  • 256 network address, in bus line used
  • Operating temperature -40 to 65 C

4
The
sensor cable
5
The sensor cable core connection tube
6
4 freely-configurable input channels
  • Vibration (sensor) cable
  • Seismic sensor (optional)
  • Frequency detector (not used)
  • PIR sensor (not used)

7
Fence detection system

8
The fence sensor cable operation
Functioning of the system Because the cable is
physically responsive to the fence to which it is
affixed, it senses any abnormal
movement/vibration of the fence. If an intruder
attempts to climb the fence , it will move
horizontally and vertically, and the sensor cable
will detect this movement. The more sensor
cable applied to a given section of fence
(depending on its characteristics and condition),
the more precise the digital conversion of the
received analog signal thats why QuadroSense
generates fewer false alarms.
9
Sensor cable
installation
10
Fence detection at work
Use of an optional, intermediate 'DC' cable
between the QuadroSense central unit and the
sensor cable permits placement of the sensor
cable up to 500m away from the central unit. If
the DC cable is cut, QuadroSense immediately
generates an alarm signal.
11
Sawing and cutting detection
  • View and adjust two related parameters in
  • real-time mode
  • HF parameters
  • To detect attempted sawing and/or
  • cutting of the sensor cable
  • LF parameters
  • To detect attempted climbing and/or
  • scaling of the fence

12
Seismic sensor
  • Max. 12 sensors per channel
  • Max. 15m diameter detection zone
  • per sensor
  • Not visible after installation

13
Programming
All inputs are programmable by computer (RS485
protocol) - it is possible to fine-tune the
system.
14
Installations world-wide
Hungary
Slovakia
Lithuania
Russia
Poland
Italy
Spain
France
Canada
15
Installation
Option 1.
16
Installation
Option 2.
17
Installation
Option 3.
18
Installation
Option 4.
19
Installation
Option 5.
20
Easy and simple combinability
21
Easy and simple assimilation
22
Easy and simple integration
23
Thank you for your attention!
Contact details peter_at_umirs.eu info_at_umirs.eu
www.umirs.eu
Write a Comment
User Comments (0)
About PowerShow.com