Application of immunological tests in diagnosis. - PowerPoint PPT Presentation

1 / 34
About This Presentation
Title:

Application of immunological tests in diagnosis.

Description:

Done by: Bilal M. Marwa, Abdullah Al-Harby. From the s of: Dr. Jad AlRab * * * * * * * * Serological Tests: types of tests where serum is used to measure the ... – PowerPoint PPT presentation

Number of Views:125
Avg rating:3.0/5.0
Slides: 35
Provided by: ZahidS2
Category:

less

Transcript and Presenter's Notes

Title: Application of immunological tests in diagnosis.


1
Application of immunological tests in
diagnosis.
  • Done by Bilal M. Marwa, Abdullah Al-Harby.
  • From the slides of Dr. Jad AlRab

2
LECTURE outline
3
Serological tests
  • Serological Tests types of tests where serum is
    used to measure the amount of antibodies present
    in it.

4
Antigen -Antibody Reactions .
  • Antigen antibody reactions are performed
    to determine the presence of either the
    antigen or antibody. (serological tests ).
  • Either the antigen or the antibody have to be
    known.
  • e.g. with a known antigen, such as
    influenza virus , a test can determine
    whether antibody to the virus is present
    or not .

5
1. Agglutination
  • In this test the antigen is particulate
    (visible, big and insoluble) (e.g. bacteria and
    red blood cells) or an inert particle
    (latex beads) coated with antigen.
  • Antibody is divalent and cross links the
    multivalent antigen to form a lattice
    network or clumps (agglutination).
  • This reaction can be performed in a tube
    or on a glass slide e.g. ABO blood
    grouping.

6
Agglutination Test positive.
negative.
Antibody.
antigen
7
2. Haemaggultination Tests
  • It is a type of agglutination test performed on
    RBCs.
  • It has two types
  • Active the antigen is the RBC itself.
  • Viruses can clump red blood cells from one
    species or another (active hemagglutination)
  • This can be inhibited by specific anti-viral
    antibodies.
  • Another example is the test used in ABO grouping.
  • Passive the antigen here is not the RBC. The RBC
    absorbs it and expresses it on the surface.
  • It will form clumps when mixed with antibodies.
  • i.e. red cells are passive carriers .

8
Haemaggultination Tests
active
passive
9
Precipitation test
  • In this test, the antigen is in soluble
    form (solution).
  • Antibody cross -links antigen molecules to
    form aggregates (precipitates) in the
    zone of equivalence optimal proportion of
    antigen and antibody.
  • Precipitation test can be performed in
    solution or in semi- solid medium (agar).

10
Zone of Equivalence
For antibody-antigen reaction to form a
precipitate that we can see, the amount of
antigen and antibody should be the same (optimum
concentration). This happens in the zone of
equivalnce.
11
3,4 Precipitation in Agar.
  • In this test, we want to measure the amount of
    antibodies in a serum sample.
  • We use the fact that a precipitation will happen
    from an anitobdy-antigen reaction ONLY if their
    amount is the same.
  • This can be made by 2 methods
  • Single Radial Immunodiffusion
  • Double Immunodiffusion.

12
3. SINGLE RADIAL IMMUNODIFFUSION
  • MECHANISM
  • We use a plate with a known amount of antigen
    (lets say 1 mg).
  • The plate is special in that it has a hole for
    insertion of serum (see next slide)
  • Then we add serum (containing antibodies) into
    the hole.
  • RESULT
  • If the amount of antibody is equal to the amount
    of antigen (1 mg), it will precipitate
    immediately, forming a small precipitation ring.
  • If the amount of antibody is higher (lets say 10
    mg) than the amount of antigen in the plate, the
    antibodies will radiate out away from the center,
    to be diluted, and will stop only if it is
    diluted enough to be equal to the amount of
    antigen.

13
(No Transcript)
14
10 mg antiobdy
3 mg antibody
1 mg antibody
The solution contains 1 mg antigen
15
Single Radial Immunodiffusion.
16
4. Double immunodiffusion.
  • Here, we have a plate with 2 holes. We add the
    antigen in one of them, and the serum in the
    other, and we allow them to diffuse and form
    precipitation lines at the points of
    optimal concentrations.
  • This method is used to determine whether
    antigens are related, identical or
    non identical.
  • (see the next slides)

17
Double immunodiffusion
18
Double immunodiffusion
19
5. Radioimmunoassay (RAST) measure specific IGE
Labeled anti-IgE helps us to measure the amount
of reaction
20
6. Enzyme Linked Immunosorbent Assay (ELISA)
  • This method is used for measuring either
    antigen or antibody in patient serum.
  • For measurement of antibody, a known antigen is
    fixed to a surface i.e. bottom of small wells on
    a plastic plate.
  • Incubated with dilutions of the patients
    serum.
  • Washed and then re-incubated with anti-human
    antibody labeled with an enzyme i.e.
    horseradish peroxidase.
  • (see next slide)

21
ELISA .
antigen
Antibody.
Enzyme Labelled antibody
Enzyme substrate.
22
ELISA .
  • Enzyme activity is measured by adding the
    substrate for the enzyme that leads
    to development of a color.
  • Color reaction is estimated in a
    spectrophotometer.
  • The amount of antibody bound is
    proportional to the enzyme activity.
  • The titer of antibody in patients serum is
    the highest dilution of the serum
    that gives a positive color reaction .

23
ELISA
Intensity of color correspond to concentration of
antibody.
24
7. Immunofluoresence
  • Fluorescent dyes e.g. fluorescein and
    rhodamine can be covalently attached to
    antibody molecules and made visible by
    ultraviolet (UV) light in a
    fluorescent microscope.
  • Such labeled antibody can be used to
    identify antigens on surface of
    microorganisms ( e.g. treponemes), in
    histological section or in other
    specimens.

25
7. Immunofluoresence
  • It can be
  • Direct a known labeled antibody interacts
    directly with an unknown antigen .
  • Indirect Immunofluoresence involves a two
    stage process
  • Patients serum is added, incubated and the
    preparation is washed.
  • Antigen is attached to a slide.
  • Antibody of interest if present will
    remain attached and can be detected by
    addition of fluorescent dye labeled
    antibody under UV light.

26
Immunofluoresence .
Antigen fixed on slide e.g. nuclear antigen .
Biopsy specimen from patient.
27
Antigen Antibody Reactions
Immunofluoresence .
28
8. Complement fixation
  • Based on the principle that antigen and
    antibody reaction activates complement .
  • Antigen and antibody, one known and the other
    unknown are mixed.
  • A measured amount of complement is added .
  • If antigen-antibody reaction has occurred it
    will combine fix complement.

29
Complement Fixation
  • An indicator system consisting of sensitized
    red blood cells (red blood cells plus anti-red
    blood cell antibody) is added.
  • If the complement was fixed because of antigen
    antibody reaction red cells will not be
    hemolyzed i.e. the test is positive.
  • If the antigen antibody reaction did not occur in
    the first step complement will not be fixed and
    will be available to lyse RBCs a negative
    test.

30
Complement Fixation Test
31
Diagnosis of cell-mediated responses
  • 1. Delayed hypersensitivity reactions .
  • - delayed skin test.
  • - patch test.
  • 2. Lymphocyte transformation test .
  • lymphocyte activation test.
  • ( detect markers by flow cytometry .)

32
contact dermatitis diagnosed by patch test .
33
Patch test for contact dermatitis .
34
Type 1 allergy diagnosed by skin prick test .
Write a Comment
User Comments (0)
About PowerShow.com