Title: Unraveling The Mystery of Stepper Motor Technology
1Unraveling The Mystery of Stepper Motor Technology
Jeramé Chamberlain Nippon Pulse America, Inc.,
USA
2What is a Open LoopStepper Motor System?
- What Are Stepper Motors?
- How Do Stepper Motors Work?
- Troubleshoot Test Stepper Motors
3Basic Stepper Application
4Stepper Motor Coil
5PHASE A
PHASE A
One PhaseStep Sequence
S
N S
S
N
?
PHASE B
PHASE B
PHASE B
PHASE B
N
STEP 1
STEP 2
PHASE A
PHASE A
Two PhaseStepper Motor
PHASE A
PHASE A
N
N
S
PHASE B
PHASE B
PHASE B
PHASE B
S
STEP 4
STEP 3
PHASE A
PHASE A
6Types of Stepper Motors
- Permanent-Magnet (PM)
- PM rotor electromagnetic coil
- Variable Reluctance (VR)
- No PM, no residual torque
- Hybrid NEMA Sizing
- Combined PM VR Technology
7Cross Section of A TwoPhase Hybrid Motor
8PM Hybrid Stepper Motors
9Bipolar Coil Winding
- Each phase is a single winding
- Current flow and electromagnetic polarity is
reverses in the windings
10Unipolar Coil Winding
- Sometimes calledfour-phase steppers
- Current flow and electromagnetic polarity is NOT
reversed in the windings. Polarity comes from
alternately energized windings
11Motors Need MaintenanceSteppers Not So Much
- Stalled motors burn up
- Steppers operate in stall condition
- Most brushes go bad
- Steppers are brushless
- All bearings go bad
- Quality Stepper bearings are rated from 90-100K
hours - People break them
- Hammers dont fix Steppers
12Ohmmeter Test With Steppers
- Bipolar
- Always 4 leads
- Resistance is the same in both windings and both
directions
- Some 8 lead motors can be connected as bipolar
13Ohmmeter Test With Steppers
- Unipolar
- 5 or 6 leads
- Resistance from each phase to Common is the same
in both directions
- If 5 leads, two commons connected
- Some 8 lead motors can be Unipolar
14Unipolar Windings Wire Colors
15Bipolar Windings Wire Colors
16Stepper Motor Electronic System
- CPU, Controller, Sequencer, Driver
- One or more parts can be combined, based on
motion complexity
17Controller Receives Coordinates
- A dedicated controller generates motion profiles
that produce smoother motor operation than just
with a CPU.
18Controller Manages Interpolates
- Some controllers provide interpolation between
motors to produce smooth XYZ motions CNC
Machines
19Two Outputs Types to Sequencer
- Pulse Direction Speed Rotation
- CW/CCW Speed Rotation
20One Controller Two Output Types
- Pulse Direction Speed Rotation
- CW/CCW Speed Rotation
- Pulse Direction is the most common format used
in the USA - PCL6045B can output both formats
21Stepper Motor Sequencers
- Sequencers read speed and direction from
controller and deliver excitation sequence to the
driver
22Bipolar Stepper Drivers
- When Q1a and Q4a (green) are on, current flows in
one direction - When Q2a and Q3a (red) are turned on, current
flow is reversed
23Unipolar Stepper Drivers
- Half the drive electronics of bipolar, and 30
less torque - However, unipolar coils allow a higher pulse rate
than bipolar, before becoming saturated.
24Constant Current - Constant Voltage
25Current Lags Voltage in an Inductor
- Torque from stepper motors is generated by
current, not voltage - PWM or Chopper drive manages current through a
switch, applied at higher voltages to induce more
winding current - Chopper delivers more torque at higher speeds
26Half Stepping A Stepper Motor
- Easiest way to accomplish half stepping is by
using 1-2 phase excitation - Divides a steppers full step angle by two 7.5/2
3.25 per half step - 30 loss of torque depending on step rate when
compared to full step - Winding is not energized during each alternating
half step
27PHASE A
PHASE A
Half SteppingSequence
S
N S
S
N
?
PHASE B
PHASE B
PHASE B
PHASE B
N
STEP 1
STEP 3
PHASE A
PHASE A
Two PhaseStepper Motor
PHASE A
PHASE A
N
N
N
N
S
S
PHASE B
PHASE B
PHASE B
PHASE B
S
S
STEP 4
STEP 2
PHASE A
PHASE A
28Microstepping A Stepper Motor
- Full step can be broken into as many as 512 parts
- Current is limited through each winding.
- Unequal pull on the magnet means it moves toward
the weaker winding - Torque falls rapidly as speed increases
- Steps are not constant for positioning
- Microstepping should only be used for smooth
movement.
29Combined Sequencer Translator