MTSC Training Course DAC New Model - PowerPoint PPT Presentation

1 / 41
About This Presentation
Title:

MTSC Training Course DAC New Model

Description:

MTSC Training Course DAC New Model & Function Prepared by: (Presenter's name) Date: (mm-dd-yyyy) * The Network Log records the activity of the cellular connections. – PowerPoint PPT presentation

Number of Views:208
Avg rating:3.0/5.0
Slides: 42
Provided by: mtscMoxaC
Category:

less

Transcript and Presenter's Notes

Title: MTSC Training Course DAC New Model


1
MTSC Training CourseDAC New Model Function
Prepared by (Presenter's name) Date (mm-dd-yyyy)
2
Agenda
  • New Model ioPAC 8020
  • New Functionality for ioLogik W5300 series
  • New Utility DA-Center

3
New Model ioPAC 8020
4
Modular RTU Controller ioPAC 8020
  • ioPAC 8020 is designed for Harsh Environments
  • Robust Aluminum Housing
  • Impact resistant
  • Prevent embrittlement
  • Wider Operation Temperature -40 75ºC
  • Anti-Vibration
  • Daisy Chain Connection
  • Built-in 2 Switch Ports
  • Hot-Swappable I/O modules

5
ioPAC 8020 Outlook
CPU module
ioPAC 8020-5-M12-T
ioPAC 8020-5-RJ45-T
OP Temp -40 75ºC, ClickGo, Active Alarming TCP, SNMP
LED Indicators
Serial Port .RS232 .RS422 .RS485
5 I/O Slots 5 I/O Slots
RM-1602-T 16 DIs
RM-2600-T 16 DOs
RM-3802-T 8AI, 420mA
RM-3810-T 8AI, 010V
RM-1050 10DI, 110Vdc Isolated
SD Card Slot .Not Available Now
Two Switch Ports M12 or RJ45
Dual 24Vdc Power Inputs
6
ioPAC 8020 Specification
  • Hardware Spec.
  • Two Switch Ports RJ45 or M12
  • Dual Power Inputs 1236Vdc, 1.26A(max)
  • Certifications UL508, EN50155
  • Software Spec.
  • Management Utility Modular-ioAdmin
  • ClickGoTM
  • SNMP V1/V2c/V3
  • Watchdog Modbus Connection/Unmatched I/O Modules

7
Non-stop Daisy Chain Support
  • Active linear bus topologies
  • Hardware pass-through function

100m
100m
100m
100m
ioPAC 8020
ioPAC 8020
ioPAC 8020
ioPAC 8020
Master Controller
8
Active Alarm System
  • Solving the system problem immediately

192.168.19.20,2006/02/19,161820,CDI00,S1
TCP/UDP
192.168.19.20
SNMP Trap
Ethernet
DI0
eMail
Internal10ms
9
Hot Swappable I/O
  • Auto Detection of installed Modules
  • Enable/Disable I/O combination check

10
Product Line Information
Model Name Description
ioPAC 8020-5-RJ45-T Modular RTU Controller w/ RJ45, -40 75 degree C, 5 I/O slots
ioPAC 8020-5-M12-T Modular RTU Controller w/ M12, -40 75 degree C, 5 I/O slots 
RM-1050-T 10 digital inputs, 110VDC, Ch-to-Ch isolated
RM-1602-T 16 digital inputs, 24VDC, Sink/Source type
RM-2600-T 16 digital outputs, 24VDC, Sink type, 0.2A
RM-3802-T 8 analog inputs, 4 to 20 mA, 16 bits
RM-3810-T 8 analog inputs, 0 to 10V, 16 bits
11
New Functions for ioLogik W5300 series
12
Agenda
  • I/O Expansion
  • Virtual Channel
  • Cellular Connection
  • Meter/Sensor Operation Mode
  • New Conditions in ClickGo

13
Expandable up to 3 external E1200 Modules
Ethernet
Supported Models E1210, E1211, E1212, E1214,
E1240
ioLogik E1210 16DIs
ioLogik E1214 6DIs, 6 Relays
ioLogik W5340 4AIs, 12DIOs, 2 Relays
ioLogik E1240 8AIs
14
E1200 as I/O Expansion
  • Make sure
  • All the E1200s are on the same subnet as W5340.
  • All the E1200s settings are configured properly.
  • The E1200s system configuration files are
    exported already.
  • Add E1200 by importing the system configuration
    file

15
E1200 as I/O Expansion
  • What if E1200 has been disconnected?
  • You can reconnect by

Right-click and choose Reconnect
16
Virtual Channel
  • Work with AI and Counter with Scaling with
    multiple operation.

17
Counter Scaling
  • The basic unit for operation Counter Scaling
  • Change of a Certain Period with unit conversion

(Counter Scaling)
(T sec)
T (second) 0 5 10 15 20 25 30 35 40 45 50
Raw Counts 0 3 5 6 14 19 24 32 44 50 59
Counter Scaling
Counter Scaling M x ?RAW D
i.e., Scaling multiply M 100, D0
T (sec)
18
Virtual Channel Operation Example
  • Counter Scaling update 5 sec (10 samples),
    Virtual Channel Interval 50 sec. per operation

Counter Scaling
T (sec)
19
Virtual Channel Application
  • Accumulation
  • Total volume of water in the last period of time
    (virtual channel interval)
  • Average
  • Average volume of water in the last period of
    time.
  • Min/Max
  • Min/Max level of water in the last period of
    time.
  • Incremental
  • Difference of water level in the last period of
    time.
  • Instantaneous
  • Current level of water

20
Optimization of Cellular Connection
  • Automatic Reconnection to network
  • Disabled by default to save bandwidth

Carrier Check for physical connection
PING Check for keeping connection Alive
21
Optimization of Cellular Connection
  • Network Log to system memory or SD
  • Disabled by default to protect the flash memory
    and save SD space
  • Helps to verify the communication problem during
    operation.

22
Meter/Sensor
  • Two Operation Modes
  • 1. Transparent Serial Tunnel
  • 2. Modbus TCP lt-gt Modbus RTU Gateway
  • Transparent Serial Tunnel Mode
  • - Support RS232/422/485 with built-in serial
    port.
  • - Provides remote server address and port
    number to bring legacy serial devices to GPRS
    network.
  • - For Serial Tunneling to work properly,
    Always On must be chosen under GPRS setting tab.
  • Modbus TCP lt-gt Modbus RTU Gateway
  • - Direct data exchange between host and field
    meter through Modbus.

23
New Condition in ClickGo
  • Support I/O information of E1200 for IF
    condition.
  • Support virtual channel as the trigger condition.
  • New criteria for IF condition
  • - IF I/O Expansion Module Connection Fail THEN
    XXX.

24
New Utility DA-Center
25
Agenda
  • Overview
  • Setting Up DA-Center

Confidential
26
Bridging to SCADA/Database System
Ethernet
Update rate 250ms
Tag Access
27
Customer Types
  • Large Scale Customers
  • Use huge number of I/O modules
  • Develop their own program and use database
  • Support ODBC driver (Oracle, MS-SQL, MySQL)
  • Small Scale Customers
  • Use few I/O modules
  • Without SCADA software
  • Analyze data with Excel or Access database
  • Use Excel to generate trend chart

28
User Interface of MOXA DA-Center
Configure Menu
Tags Information
MOXA Active OPC Server List
Event Log Window
29
Setting up the DA-Center
  • 5 steps to get it DONE!
  • Create a new project.
  • Add a new dataset either to a file or database.
  • Choose the OPC server.
  • Map OPC tags to dataset.
  • Start Recording.

30
Setting up the DA-Center (1)
  • Ensure the AOPC is installed/configured and
    activated.

31
Setting up the DA-Center (2)
Run DA-Center
Add a dataset
32
Setting up the DA-Center (3)
Specify a name for your database
Choose where you want to record your data
33
Setting up the DA-Center (4)
Choose or create a table
Fields to display
34
Setting up the DA-Center (5)
Select an OPC server
35
Setting up the DA-Center (6)
Specify a group name
Choose the update rate 100ms 500ms
Fields to display
Choose the tags for your group
36
Setting up the DA-Center (7)
Map your tags to dataset
Choose the tags you want to link to your dataset
37
Setting up the DA-Center (8)
Now its time to start recording
The event log window showing the current status
38
Setting up the DA-Center (9)
Final result in Excel
39
Setting up the DA-Center (10)
Trend Chart Line chart Bar chart
40
Q A
41
(No Transcript)
Write a Comment
User Comments (0)
About PowerShow.com