1
SSERemote Telemetry UnitSSE RTU
2
Telemetry Systems40-20 Years Ago
  • Rural Pumping Schemes Controlled by hand
  • Urban Schemes Controlled by Relay Logic
    Instrumentation
  • Very Basic Telemetry Systems Hard Wired with
    Mimic
  • Radio Telemetry Starting to emerge for remote
    control.

3
15 to 20 Years Ago
  • Demand for Operational Function Alarms
    Remote Control
  • Slow Radios (300 Baud) Installed Limited Data
    Throughput
  • Cable Replacer Type Telemetry System
  • Control Relay Logic/Basic PLC
  • Small Amount of Data Mainly Basic Alarming
    Limited Control
  • Master Station Mainly Mimic Panels DOS Based
    SCADA

4
Typical Telemetry Network Then!
5
Scada Application
Evolution of Technology
  • Driven by two main influences
  • From Client Side (Pulling forces)
  • Plants and distribution networks got more
    complex.
  • The demand for more information at a quicker
    rates.
  • Better / Faster service delivery.
  • From Technology offerings (Pushing forces)
  • New technologies offer better and smarter
    solutions
  • Faster processing power.
  • More robust communication networks.

6
Modern RTUs
  • Compact more I/O with smaller footprint
  • Connect to all wide area networks compatible
    with new IP based networks
  • Intelligent PLC Based processing capabilities
  • OPC Compliant Software open standard for
    industrial applications
  • Remote Diagnostics Network wide fault finding
    and configuration tools
  • Support for IEDs protocol support for
    intelligent devices
  • Protocol Standardization

7
SSE Design Philosophy
  • Client Requirement driven.
  • Technology driven.
  • Follow well established engineering practises.
  • Hardware Software are modular in design.
  • To design products that are
  • Economical
  • User friendly
  • Open
  • Compatible
  • Expandable
  • Always backwards compatible to older version RTUs

8
Typical Telemetry System Layout
SCADA, MES Information Systems
Backhaul Communication Network
Monitoring Equipment RTUs
Interfacing Connectivity
Instrumentation IEDs
Soft Starters
Energy Meters
Security Access Control
Actuators
Flow Meters
PLCs
9
SSE RTU-12 Features
  • Instrumentation IEDs
  • A wider choice of instruments.
  • Different interface signals
  • 4-20 mAmp, -20 - 20 mAmp
  • Volt mVolt.
  • Frequency pulses.
  • Micro Processor based instruments got more an
    more popular.
  • Intelligent Electronic Devices (IEDs)
  • IEDs with Direct communication capabilities.
  • Running different protocols,
  • At different baud rate,
  • Using different communication mediums.
  • IEDs got more and more popular, but started
    posing more and more interfacing challenges.

10
SSE RTU-12 Featurescont.
  • Interfacing
  • Discrete signals via conventional cabling
  • IEDs supported on a wide variety of interfacing
    and communication networks
  • RS-232
  • RS-485
  • Ethernet LAN
  • Etc
  • RTU-12 Equipment supports these mediums
    simultaneously

11
SSE RTU-12 Featurescont.
  • Communications Backhaul
  • Communication between remote RTUs and Master
    SCADA computers.
  • Protocols
  • DNP-3 Slave.
  • IEC 60870-5-101.
  • Modbus.
  • DF-1
  • Enermax.
  • Etc.
  • Running different communication mediums
  • Analogue Radio.
  • Data Radio.
  • Dial-Up.
  • SMS / GPRS / 3G.
  • Fibre Optic.
  • LAN
  • Wireless LAN.
  • Wi-Max
  • Satellite.

12
SSE RTU-12 Featurescont.
  • RTU-12 Summary
  • Monitor discrete I/O.
  • Interface simultaneously with IEDs on multiple
    protocols and on multiple mediums.
  • Backhaul comms interfacing on multiple protocols
    and on multiple mediums.
  • Data concentrator and manager.
  • Configurability vs Programmability.
  • PLC like programming for local or distributed
    control.
  • Intelligent data logger with event reporting and
    time stamping to 1ms resolution.
  • Advanced alarming direct to users cell phone via
    SMS.
  • Comprehensive configuration toolbox.
  • Advanced diagnostics functionality.

13
The Road ahead
  • Six new product releases in the next 12 Months.
  • Maestro 2000 RTU June 2011.
  • Based on RTU-12 technologies.
  • Speed 3 MIPS
  • New Enclosures.
  • Memory 640 K
  • New Switch-mode PSU.
  • Maestro 4000 RTU Feb 2012
  • Complete new Hardware design
  • Speed 66 MIPS
  • Memory 64 Meg.
  • 4 RS 232 Ports standard / One Isolated RS-485
    optional
  • Ethernet Port.
  • USB Port.
  • Serial / Remote IO Modules.

14
The Road ahead
  • IO Expansion Modules Feb 2012
  • Highspeed Serial Interfacing between RTU IO
    Modules.
  • Processor on each IO Module.
  • Remote IOs.
  • 1 msSec Time Stamping.
  • Maestro 8000 RTU Sept 2012
  • Complete new Hardware design.
  • Speed 250 MIPS
  • Memory 64 Meg.
  • Run Real-time Operating System Linux
  • 4 RS 232 Ports standard / One Isolated RS-458
    optional
  • Ethernet Port.
  • USB Host Device.
  • Serial / Remote IO Modules.
  • 1028 AIN, 1028 DIN, 1028 DOT, 1028 CIN, 512 AOT,
    1028 FIN