Title: KX-TDA200/100 System (Ver.1.0)
1 KX-TDA200/100 System (Ver.1.0)
Chapter 1Hardware Configuration EU
- Kyushu Matsushita Electric Co., Ltd.
- Telecom Division
- Edition 1.2 , 19, SEP., 2002
2Chapter 1Hardware Configuration EU
1. System Connection Diagram 2. Inside Cabinet
Configuration
3. The characteristic of the
Hardware 4. System Capacity 5. System Card
configuration 6. Cards Specification
31. System Connection Diagram
LAN
42. Inside Cabinet Configuration (KX-TDA200)
Serial RS232 Port for SMDR/Prog.
USB Port for CTI / Prog.
1 option Slot
10 Free Slots (Slot card)
52. Inside Cabinet Configuration (KX-TDA100)
Serial RS232 Port for SMDR/Prog.
USB Port for CTI / Prog.
5 Free Slots(Slot card)
1 Option Slot
63. New Hardware Architecture(1/1)
- (1) Powerful 32bit CPU(base clock 133MHz) in MPR
(170MIPS) - (2) Load decentralization control
processing(MPRlt-gtLPR) - (3) No EP-ROM (Onsite/Remote Software download)
- (4) Free Slot Configuration
- (5) Installer Friendly Wiring
- (6) New type Option Card
- - IP-GW Trunk Card
- - CTI-LINK Card
- - CS-INF Card
- - PRI(QSIG) Card
- - OPB3 Card
- (7) No Battery Adapter Required
- (8) Power on Maintenance
- (9) 19-inch rack available with special adapter
7No Battery Adapter Required
(With Battery charger)
(It is useful for the maintenance)
M type 140W (Normal Traffic) L type 279W
(Normal Traffic)
(Batteries became three from two)
8Installer Friendly Wiring
Enough space for wiring
9Easy wall mounting system
1019-inch rack available with special adapter
TDA200
Special adapter
TDA100
114. System Configuration
Version 1.1
125. System Capacity (1/5)
ltCard Maxgt
KX-TDA200
(1) Extension Card Max.8 cards (Note
CS-INFMax.4 cards, Extension Card CS-INFMax.8
cards) (2) Trunk Card(include ISDN-EXT) Max.8
cards (Note 1 E1,PRI Cards count as 2
cards, VoIP Card needs 2 slots) (3) Extension
Card Trunk Card Max.10 cards
KX-TDA100
(1) Extension Card Max.4 cards (Note
CS-INFMax.2 cards, Extension Card CS-INFMax.4
cards) (2) Trunk Card(include ISDN-EXT) Max.4
cards (Note 1 E1,PRI Cards count as 2
cards, VoIP Card needs 2 slots) (3) Extension
Card Trunk Card Max.5 cards
ltPort Maxgt
Line Type
TDA100
TDA200
ltNoticegt
64
128
Trunk
Port Max increase when use PRI / E1 Cards.
Extension
64
128
Total
80
160
135. System Capacity (2/5)
(Method of estimating power supply capacity)
Power Factor
512 PU
PUPower Unit, 1PU1DPT
L
Type
Power Factor
New DPT
1PU /Unit
VPS
1PU /Port (2CH)
2PU /Port (2CH)
BRI Extension
Old DPT
4PU /Unit
Old APT
4PU /Unit
DHLC
8PU /Card
SLT
128 PU
128 PU
SLC8
8PU /Card
M
M
64 PU
SLC16/MSLC16
16PU /Card
S
CS
4PU /CS
TDA100
TDA200
You have to calculate not with a unit but
with the card.
It is costly, when changing to S-gtM and M-gtL.
Therefore, the size is decided by thinking about
the future.
145. System Capacity (3/5)
(Method of estimating power supply capacity)
ltExample 1 (TDA200)gt
Telephone Type
Number
Calculation
Total P.U.
New DPT
10 Units
10X1
10
Old DPT
10X4
40
10 Units
APT
10X4
40
10 Units
16 Units
SLT16
1X16
16
4 Units
SLT8
1X8
8
VPS
1 Port
1X1
1
Type
Power Factor
New DPT
1PU /Unit
Total 115 PU
VPS
1PU /Port (2CH)
It is OK with the M type
BRI Extension
2PU /Port (2CH)
Old DPT
4PU /Unit
APT
4PU /Unit
DHLC
8PU /Card
SLT
SLC8
8PU /Card
SLC16/MSLC16
16PU /Card
CS
4PU /CS
155. System Capacity (4/5)
(Method of estimating power supply capacity)
ltExample 2 (TDA200)gt
Telephone Type
Number
Calculation
Total P.U.
New DPT
10 Units
10X1
10
Old DPT
10X4
40
10 Units
APT
10X4
40
10 Units
4 Units
SLT8
1X8
8
1 Units
VPS
1X1
1
CS
8 CS
8X4
32
Type
Power Factor
New DPT
1PU /Unit
Total 131 PU
VPS
1PU /Port (2CH)
M type cannot be used
BRI Extension
2PU /Port (2CH)
Old DPT
4PU /Unit
APT
4PU /Unit
DHLC
8PU /Card
SLT
SLC8
8PU /Card
SLC16/MSLC16
16PU /Card
CS
4PU /CS
165. System Capacity (5/5)
(Max Terminals)
Line Type
TDA100
TDA200
VPS(TVP System) (DPT Integration)
2
2
8
8
PC Console
16
32
CS
Wireless
128(32Group)
128(32Group)
PS
Door Phone / Opener External Relay / Sensor
8
16
176. Cards Specification (1/20)
(Main Processor Card MPR 1/3)
MPR Main Processor card (Pre-installed)
SD(Secure Digital) card (Pre-installed) - Store
Main Software - Store Customer Database -
Replaceable
SD Slot
RMTAnalogue Modem
Analogue Modem card (Optional) - Support Max.
56K bps (V.90)
USB Interface (Pre-installed) - Programming /
CTI
USB I/F
MEXExpansion Memory
Expansion Memory card (Optional) - Available
from Version 1.1 Software
Serial I/F
RS232-C / V.24 Interface (Pre-installed) -
Programming / SMDR
186. Cards Specification (2/20)
(Main Processor Card MPR 2/3)
Card Name
Function
Card Configuration
FLASH 512KB SDRAM 8MB SRAM 1.0MB
(TDA100 0.5MB) Slide SW ( Initial / Normal)
TSW is in both MPR and LPR.
MPR
CPU SH7709A (133MHz/32bit)
(Main Central Processing unit )
RMT
Analog modem card
Modem IC (V.90 support)
(Remote Maintenance Trunk)
(This card is unnecessary with the ISDN remote)
KX-TDA0196
Flash 8MB SDRAM 8MB SRAM 1MB (Version 1.1)
MEX
Reserved for the expansion of features
(Memory Expand)
KX-TDA0105
SD
Software preinstalled System does not work if a
SD card isnt mounted System data Back-up
Memory size 16MB
(Built in )
(Secure Digital Card)
196. Cards Specification (3/20)
(Main Processor Card MPR 3/3)
LED1 (BATT Alarm)
LED2 (SD Access)
Reset Switch
System Initialize Switch
(Include TSW)
USB Port
MOH2
MOH1
Pager 2
Pager 1
ASIC Application Specific Integrated circuit
206. Cards Specification (4/20)
Slot Card (Extension 1/5)
Extension card (Optional) Installed in Free
slot
DHLC8
DLC 8DLC 16
8 Digital Hybrid Line card - Support 8 D-PT
and 8 SLT - 2 Power Failure port - 8 DTMF
Receiver()
8 or 16 Digital Proprietary Line card
SLC8 SLC16
MSLC16
8 or 16 SLT Line card - 2 or 4 Power Failure
port - 8 or 16 DTMF Receiver()
16 SLT with Message Lamp - 4 Power Failure
port - 16 DTMF Receiver()
CSINF 8
8 DECT-CS Interface
() This merit is Non Blocking and Toll
restriction for SLT
216. Cards Specification (5/20)
Slot Card (Extension 2/5)
Card Name
Function
Card Configuration
Max use
8 DPT/ APT/SLT/DSS Console ports 2 power failure
ports 8 DTMF receiver Level control per
card Dont support analog OHCA. Software
downloadable from PBX DHLC card is treated as 16
extension card.
DHLC8
CPU SH-1(12.288MHz) Flash 512KB External RAM
1KB Internal 128KB External
TDA200 8 TDA100 4
( Digital Hybrid Line)
KX-TDA0170
DLC16 (DLC8)
CPU SH-1(12.288MHz) Flash 512KB External RAM
1KB Internal 128KB External
16(8) port DPT card DSS console can be
connected Level control per card Software
downloadable from PBX
TDA200 8 TDA100 4
(Digital Proprietary Line)
KX-TDA0172 (0171)
MSLC16
Message Waiting Lamp control 16 DTMF receiver 4
power failure ports Level control per card
NO CPU
TDA200 8 TDA100 4
(SLT MW Lamp)
KX-TDA0175 (0174)
SLC16(SLC8)
16(8) DTMF receiver 4(2) power failure
ports Level control per card
TDA200 8 TDA100 4
ltSLC8gt CPU SH-1(12.288MHz) Flash 512KB
External RAM 1KB Internal 128KB
External ltSLC16gt NO CPU
(8-port SLT Line)
KX-TDA0173
CPU SH-1(12.288MHz) Flash 512KB External RAM
1KB Internal 128KB External
For DECT(4ch) / 2.4GHzSS-FH(3ch) Software
downloadable from PBX Level control per port
CSIF8
TDA200 4 TDA100 2
(8-port Cell Station I/F )
KX-TDA0144
Level control per card -15dB to 15dB is
available for both send and receive
226. Cards Specification (6/20)
Slot Card (Extension 3/5)
ltAvailable terminal for Extension Cardgt
236. Cards Specification (7/20)
Slot Card (Extension 4/5)
500m
720m
830m
New DPT(KX-T76XX Series, KX-T7560/7565)
444m
694m
1000m
246. Cards Specification (8/20)
Slot Card (Extension 5/5)
CSIF8 Card
Trans for the transmission
LED1 (Card status)
Echo Canceling
ASIC (CS-LPR communication)
RJ45
ASIC (MPR-LPR communication)
CPU
Flash ROM
256. Cards Specification (9/20)
Slot Card (Trunk 1/6)
Trunk card (Optional) Installed in Free slot
LCOT 8LCOT 16
8 or 16 Analogue CO card
EM 8
8 EM card - Type 5
Caller ID card for 8 CO
CID8
BRI 4 BRI 8
PRI 30
4 or 8 Basic RateISDN card
1 Primary RateISDN card (30-ch) - RJ45 / BNC
E1
IP-GW 4
1 E1 card - RJ45 / BNC
4 IP Gateway card - 10 Base-T - Requires 2-slot
266. Cards Specification (10/20)
Slot Card (Trunk 2/6)
Card Name
Function
Card Configuration
Max use
Can detect polarity reversal 4(2) power failure
ports Level control per card
LCOT16 (LCOT8)
NO CPU
TDA200 8 TDA100 4
(Loop Start Trunk)
2-daughter board on LCOT16
1-daughter board on LCOT8
KX-TDA0181 (0180)
CID/PAY8
(Caller ID/Pay Tone)
NO CPU
TDA200 16 TDA100 8
CO Caller ID type -gt Bell/ETSI/DTMF type
KX-TDA0189
CID8
(Caller ID )
TDA200 16 TDA100 8
CO Caller ID type -gt Bell/ETSI/DTMF type
NO CPU
KX-TDA0193
EM 8
CPUSH-1(12.288MHz) FLASH512KB RAM
Internal 1KB SRAM128KB
Type5 DTMF/Pulse Dial Signaling Type
Continuous EM / Pulsed EM Software
downloadable from PBX
TDA200 8 TDA100 4
(EM TIE line card)
KX-TDA0184
RJ45/BNC(Slide SW) (ITU-T / ANSI
) ConnectorRJ45 (EIA/TIA) CPU
SH-1(12.288MHz) FLASH 512KB SRAM
512KB DSP mounted
E1
Level control per card Software downloadable
from PBX MFC-R2 / DTMF / Pulse Dial Signaling
Type Digital R2 / Continuous EM /
Pulsed EM
TDA200 4 TDA100 2
KX-TDA0188
Level control per card -15dB to 15dB is
available for both send and receive
276. Cards Specification (11/20)
Slot Card (Trunk 3/6)
Card Name
Function
Card Configuration
Max use
CPU SH-1(12.288MHz) FLASH 512KB SRAM
512KB RJ45
Extension / CO trunk per port Software
downloadable form PBX Level control per
card Only S/T point Power Failure pair port
port1 for BRI CO port2 for BRI
Extension Euro-ISDN / ETS
BRI8 (BRI4)
TDA200 8 TDA100 4
(ISDN Basic)
(Q-SIG)
KX-TDA0288 (0284)
CPU SH-1(12.288MHz) FLASH 512KB SRAM
512KB PRI30 BNC/RJ45 (Slide SW) PRI23
RJ45
CO Trunk Software Downloadable from PBX Level
control per card Impedance selective
(75/120ohms) Euro-ISDN / ETS / NT1
PRI30 (PRI23)
TDA200 4 TDA100 2
(ISDN Primary)
(Q-SIG)
KX-TDA0290 (0290)
CPU SH-1(12.288MHz) Flash 512KB External
RAM 1KB Internal 128KB
External RJ45(CO trunk side)
BRI2 DHLC4
2-port ISDN basic I/F for Extension / CO
trunk per port DPT / APT / SLT / DSS / Console
card with 4-port.
TDA200 4 TDA100 2
(Ver. 1.1)
(Q-SIG)
KX-TDA
CPU SH-1(12.288MHz) Flash 512KB External
RAM 1KB Internal 128KB External RJ45 (CO
trunk side)
LCOT4DHLC4
4-port analog LCOT (polarity reversal) 1
power failure port 4-Ports DPT / APT / SLT /
DSS / Console
TDA200 4 TDA100 2
(Ver. 1.1)
KX-TDA
CID4
CO Caller ID type -gt Bell/ETSI/DTMF type
TDA200 4 TDA100 2
(Ver. 1.1)
NO CPU
KX-TDA
Level control per card -15dB to 15dB is
available for both send and receive
286. Cards Specification (12/20)
Slot Card (Trunk 4/6)
You are able to use the straight cable both LINE
and EXTN. And E1/T1 is also same.
296. Cards Specification (13/20)
Slot Card (Trunk 5/6)
Card Name
Function
Card Configuration
Max use
VoIP H.323 V.2 Supports VoIP H.323 V.2 Voice
coded G.729a, G723.1 FAXG3 64 Kbps , Physical
I/F 10 BASE-T
IP-GW4
(occupy 2 slots)
TDA200 4 TDA100 2
(Q-SIG)
KX-TDA0480
306. Cards Specification (14/20)
Slot Card (Trunk 6/6)
IP-GW4 Card
DSP
CPU
10 Base T Ethernet Port
SD RAM
FPGA
RS232C Maintenance Port
(Communicate Lower card and Upper card)
Upper Card( VoIP/H.323 control )
Lower Card(Communicate MPR and Upper card)
FPGA Field Programmable Gate Array
316. Cards Specification (15/20)
CTI-LINK Card(1/3)
Option card Installed in Free slot Option
Slot
CTI-LINK
CTI Interface Card - 10 Base-T
326. Cards Specification (16/20)
CTI-LINK Card(2/3)
Card Name
Function
Card Configuration
Max use
Ethernet card for CTI communication Only data
controlled Physical I/F 10BASE-T
CPU SH7709A(133MHZ) FLASH512KB SDRAM8MB
CTI-LINK
TDA200 1 TDA100 1
(LAN I/F )
KX-TDA0410
336. Cards Specification (17/20)
CTI-LINK Card (3/3)
LAN Controller
LED1 (Card status)
Flash Memory
LED2 (Link status)
Trans
SD RAM
RJ45
ASIC (MPR-LPR communication)
CPU
346. Cards Specification (18/20)
Option Card (1/3)
Option card Installed in Option Slot
OPB 3
Optional card mounting base board - 3 small
optional card space for MSG4 / DPH4 / EIO4 and
ECHO16
4-Ch. Message card - Total 8 min. Max. 64 MSG
MSG4
4 Doorphone /Door Opener card
DPH4
4 Sensor Input / 4 Relay Output card
EIO4
(Ver. 1.1)
16-Ch. Echo Cancelingcard
ECHO16
356. Cards Specification (19/20)
Option Card (2/3)
Card Name
Function
Card Configuration
Max use
OPB3
CPU SH1(12.288MHz) ROM 512KB(External) RAM
1KB(internal) 128KB(External)
TDA200 4 TDA100 2
Max 3 optional cards mountable Software
Downloadable from PBX
(Optional base card)
KX-TDA0190
OGM for DISA call / Queuing call / Wake
up Call / Internal hold melody DTMF
detection, CO-CO conversation DTMF
repeater functions
NO CPU Total 8 min. Max. 64 messages for
System Maximum of 3 MSG4 cards can be mounted on
the OPB3 card.
MSG4
TDA200 4 TDA100 2
(4-channels)
KX-TDA0191
NO CPU Maximum of 3 DPH4 cards can be mounted
on the OPB3 card.
DPH4
TDA200 4 TDA100 2
4-port Door-phone Door-opener card Door-phone
(T30865)
KX-TDA0161
DPH2 (-G)
NO CPU Maximum of 3 DPH2 cards can be mounted on
the OPB3 card.
TDA200 8 TDA100 4
2-port Door-phone Door-opener card For Germany
D-phone I/F
KX-TDA0162
NO CPU Maximum of 3 EIO cards can be mounted on
the OPB3 card.
EIO4
(External I/O) 4 Outputs (Relay) 4
Inputs Used for external relay / sensor
(Ver. 1.1)
TDA200 4 TDA100 2
KX-TDA0164
ECHO16
TDA200 2 TDA100 2
NO CPU Only 1 ECHO16 card can be mounted on the
OPB3 card.
16-port Echo Canceling card
KX-TDA0166
366. Cards Specification (20/20)
Option Card (3/3)
OPB3
DPH2
Extended
I/O
(back
side)
DPH4
Extended
I/O
MSG4
Extended
I/O
DSP
Flash
Memory
(back
side)
37Chapter 1Hardware Configuration EU
Thank you very much !