KX-TDA200/100 System (Ver.1.0) - PowerPoint PPT Presentation

1 / 37
About This Presentation
Title:

KX-TDA200/100 System (Ver.1.0)

Description:

System Connection Diagram ... Slot Card (Extension 1/5) (*): This merit is Non Blocking and ... Lower Card(Communicate MPR and Upper card) IP-GW4 Card FPGA FPGA ... – PowerPoint PPT presentation

Number of Views:540
Avg rating:3.0/5.0
Slides: 38
Provided by: 633694
Category:

less

Transcript and Presenter's Notes

Title: KX-TDA200/100 System (Ver.1.0)


1
KX-TDA200/100 System (Ver.1.0)
Chapter 1Hardware Configuration EU
  • Kyushu Matsushita Electric Co., Ltd.
  • Telecom Division
  • Edition 1.2 , 19, SEP., 2002

2
Chapter 1Hardware Configuration EU
1. System Connection Diagram 2. Inside Cabinet
Configuration
3. The characteristic of the
Hardware 4. System Capacity 5. System Card
configuration 6. Cards Specification
3
1. System Connection Diagram
LAN
4
2. Inside Cabinet Configuration (KX-TDA200)
Serial RS232 Port for SMDR/Prog.
USB Port for CTI / Prog.
1 option Slot
10 Free Slots (Slot card)
5
2. Inside Cabinet Configuration (KX-TDA100)
Serial RS232 Port for SMDR/Prog.
USB Port for CTI / Prog.
5 Free Slots(Slot card)
1 Option Slot
6
3. New Hardware Architecture(1/1)
  • (1) Powerful 32bit CPU(base clock 133MHz) in MPR
    (170MIPS)
  • (2) Load decentralization control
    processing(MPRlt-gtLPR)
  • (3) No EP-ROM (Onsite/Remote Software download)
  • (4) Free Slot Configuration
  • (5) Installer Friendly Wiring
  • (6) New type Option Card
  • - IP-GW Trunk Card
  • - CTI-LINK Card
  • - CS-INF Card
  • - PRI(QSIG) Card
  • - OPB3 Card
  • (7) No Battery Adapter Required
  • (8) Power on Maintenance
  • (9) 19-inch rack available with special adapter

7
No Battery Adapter Required
(With Battery charger)
(It is useful for the maintenance)
M type 140W (Normal Traffic) L type 279W
(Normal Traffic)
(Batteries became three from two)
8
Installer Friendly Wiring
Enough space for wiring
9
Easy wall mounting system
10
19-inch rack available with special adapter
TDA200
Special adapter
TDA100
11
4. System Configuration
Version 1.1
12
5. System Capacity (1/5)
ltCard Maxgt
KX-TDA200
(1) Extension Card Max.8 cards (Note
CS-INFMax.4 cards, Extension Card CS-INFMax.8
cards) (2) Trunk Card(include ISDN-EXT) Max.8
cards (Note 1 E1,PRI Cards count as 2
cards, VoIP Card needs 2 slots) (3) Extension
Card Trunk Card Max.10 cards
KX-TDA100
(1) Extension Card Max.4 cards (Note
CS-INFMax.2 cards, Extension Card CS-INFMax.4
cards) (2) Trunk Card(include ISDN-EXT) Max.4
cards (Note 1 E1,PRI Cards count as 2
cards, VoIP Card needs 2 slots) (3) Extension
Card Trunk Card Max.5 cards
ltPort Maxgt
Line Type
TDA100
TDA200
ltNoticegt
64
128
Trunk
Port Max increase when use PRI / E1 Cards.
Extension
64
128
Total
80
160
13
5. System Capacity (2/5)
(Method of estimating power supply capacity)
Power Factor
512 PU
PUPower Unit, 1PU1DPT
L
Type
Power Factor
New DPT
1PU /Unit
VPS
1PU /Port (2CH)
2PU /Port (2CH)
BRI Extension
Old DPT
4PU /Unit
Old APT
4PU /Unit
DHLC
8PU /Card
SLT
128 PU
128 PU
SLC8
8PU /Card
M
M
64 PU
SLC16/MSLC16
16PU /Card
S
CS
4PU /CS
TDA100
TDA200
You have to calculate not with a unit but
with the card.
It is costly, when changing to S-gtM and M-gtL.
Therefore, the size is decided by thinking about
the future.
14
5. System Capacity (3/5)
(Method of estimating power supply capacity)
ltExample 1 (TDA200)gt
Telephone Type
Number
Calculation
Total P.U.
New DPT
10 Units
10X1
10
Old DPT
10X4
40
10 Units
APT
10X4
40
10 Units
16 Units
SLT16
1X16
16
4 Units
SLT8
1X8
8
VPS
1 Port
1X1
1
Type
Power Factor
New DPT
1PU /Unit
Total 115 PU
VPS
1PU /Port (2CH)
It is OK with the M type
BRI Extension
2PU /Port (2CH)
Old DPT
4PU /Unit
APT
4PU /Unit
DHLC
8PU /Card
SLT
SLC8
8PU /Card
SLC16/MSLC16
16PU /Card
CS
4PU /CS
15
5. System Capacity (4/5)
(Method of estimating power supply capacity)
ltExample 2 (TDA200)gt
Telephone Type
Number
Calculation
Total P.U.
New DPT
10 Units
10X1
10
Old DPT
10X4
40
10 Units
APT
10X4
40
10 Units
4 Units
SLT8
1X8
8
1 Units
VPS
1X1
1
CS
8 CS
8X4
32
Type
Power Factor
New DPT
1PU /Unit
Total 131 PU
VPS
1PU /Port (2CH)
M type cannot be used
BRI Extension
2PU /Port (2CH)
Old DPT
4PU /Unit
APT
4PU /Unit
DHLC
8PU /Card
SLT
SLC8
8PU /Card
SLC16/MSLC16
16PU /Card
CS
4PU /CS
16
5. System Capacity (5/5)
(Max Terminals)
Line Type
TDA100
TDA200
VPS(TVP System) (DPT Integration)
2
2
8
8
PC Console
16
32
CS
Wireless
128(32Group)
128(32Group)
PS
Door Phone / Opener External Relay / Sensor
8
16
17
6. Cards Specification (1/20)
(Main Processor Card MPR 1/3)
MPR Main Processor card (Pre-installed)
SD(Secure Digital) card (Pre-installed) - Store
Main Software - Store Customer Database -
Replaceable
SD Slot
RMTAnalogue Modem
Analogue Modem card (Optional) - Support Max.
56K bps (V.90)
USB Interface (Pre-installed) - Programming /
CTI
USB I/F
MEXExpansion Memory
Expansion Memory card (Optional) - Available
from Version 1.1 Software
Serial I/F
RS232-C / V.24 Interface (Pre-installed) -
Programming / SMDR
18
6. Cards Specification (2/20)
(Main Processor Card MPR 2/3)
Card Name
Function
Card Configuration
FLASH 512KB SDRAM 8MB SRAM 1.0MB
(TDA100 0.5MB) Slide SW ( Initial / Normal)
TSW is in both MPR and LPR.
MPR
CPU SH7709A (133MHz/32bit)
(Main Central Processing unit )
RMT
Analog modem card
Modem IC (V.90 support)
(Remote Maintenance Trunk)
(This card is unnecessary with the ISDN remote)
KX-TDA0196
Flash 8MB SDRAM 8MB SRAM 1MB (Version 1.1)
MEX
Reserved for the expansion of features
(Memory Expand)
KX-TDA0105
SD
Software preinstalled System does not work if a
SD card isnt mounted System data Back-up
Memory size 16MB
(Built in )
(Secure Digital Card)
19
6. Cards Specification (3/20)
(Main Processor Card MPR 3/3)
LED1 (BATT Alarm)
LED2 (SD Access)
Reset Switch
System Initialize Switch
(Include TSW)
USB Port
MOH2
MOH1
Pager 2
Pager 1
ASIC Application Specific Integrated circuit
20
6. Cards Specification (4/20)
Slot Card (Extension 1/5)
Extension card (Optional) Installed in Free
slot
DHLC8
DLC 8DLC 16
8 Digital Hybrid Line card - Support 8 D-PT
and 8 SLT - 2 Power Failure port - 8 DTMF
Receiver()
8 or 16 Digital Proprietary Line card
SLC8 SLC16
MSLC16
8 or 16 SLT Line card - 2 or 4 Power Failure
port - 8 or 16 DTMF Receiver()
16 SLT with Message Lamp - 4 Power Failure
port - 16 DTMF Receiver()
CSINF 8
8 DECT-CS Interface
() This merit is Non Blocking and Toll
restriction for SLT
21
6. Cards Specification (5/20)
Slot Card (Extension 2/5)
Card Name
Function
Card Configuration
Max use
8 DPT/ APT/SLT/DSS Console ports 2 power failure
ports 8 DTMF receiver Level control per
card Dont support analog OHCA. Software
downloadable from PBX DHLC card is treated as 16
extension card.
DHLC8
CPU SH-1(12.288MHz) Flash 512KB External RAM
1KB Internal 128KB External
TDA200 8 TDA100 4
( Digital Hybrid Line)
KX-TDA0170
DLC16 (DLC8)
CPU SH-1(12.288MHz) Flash 512KB External RAM
1KB Internal 128KB External
16(8) port DPT card DSS console can be
connected Level control per card Software
downloadable from PBX
TDA200 8 TDA100 4
(Digital Proprietary Line)
KX-TDA0172 (0171)
MSLC16
Message Waiting Lamp control 16 DTMF receiver 4
power failure ports Level control per card
NO CPU
TDA200 8 TDA100 4
(SLT MW Lamp)
KX-TDA0175 (0174)
SLC16(SLC8)
16(8) DTMF receiver 4(2) power failure
ports Level control per card
TDA200 8 TDA100 4
ltSLC8gt CPU SH-1(12.288MHz) Flash 512KB
External RAM 1KB Internal 128KB
External ltSLC16gt NO CPU
(8-port SLT Line)
KX-TDA0173
CPU SH-1(12.288MHz) Flash 512KB External RAM
1KB Internal 128KB External
For DECT(4ch) / 2.4GHzSS-FH(3ch) Software
downloadable from PBX Level control per port
CSIF8
TDA200 4 TDA100 2
(8-port Cell Station I/F )
KX-TDA0144
Level control per card -15dB to 15dB is
available for both send and receive
22
6. Cards Specification (6/20)
Slot Card (Extension 3/5)
ltAvailable terminal for Extension Cardgt
23
6. Cards Specification (7/20)
Slot Card (Extension 4/5)
500m
720m
830m
New DPT(KX-T76XX Series, KX-T7560/7565)
444m
694m
1000m
24
6. Cards Specification (8/20)
Slot Card (Extension 5/5)
CSIF8 Card
Trans for the transmission
LED1 (Card status)
Echo Canceling
ASIC (CS-LPR communication)
RJ45
ASIC (MPR-LPR communication)
CPU
Flash ROM
25
6. Cards Specification (9/20)
Slot Card (Trunk 1/6)
Trunk card (Optional) Installed in Free slot
LCOT 8LCOT 16
8 or 16 Analogue CO card
EM 8
8 EM card - Type 5
Caller ID card for 8 CO
CID8
BRI 4 BRI 8
PRI 30
4 or 8 Basic RateISDN card
1 Primary RateISDN card (30-ch) - RJ45 / BNC
E1
IP-GW 4
1 E1 card - RJ45 / BNC
4 IP Gateway card - 10 Base-T - Requires 2-slot
26
6. Cards Specification (10/20)
Slot Card (Trunk 2/6)
Card Name
Function
Card Configuration
Max use
Can detect polarity reversal 4(2) power failure
ports Level control per card
LCOT16 (LCOT8)
NO CPU
TDA200 8 TDA100 4
(Loop Start Trunk)
2-daughter board on LCOT16
1-daughter board on LCOT8
KX-TDA0181 (0180)
CID/PAY8
(Caller ID/Pay Tone)
NO CPU
TDA200 16 TDA100 8
CO Caller ID type -gt Bell/ETSI/DTMF type
KX-TDA0189
CID8
(Caller ID )
TDA200 16 TDA100 8
CO Caller ID type -gt Bell/ETSI/DTMF type
NO CPU
KX-TDA0193
EM 8
CPUSH-1(12.288MHz) FLASH512KB RAM
Internal 1KB SRAM128KB
Type5 DTMF/Pulse Dial Signaling Type
Continuous EM / Pulsed EM Software
downloadable from PBX
TDA200 8 TDA100 4
(EM TIE line card)
KX-TDA0184
RJ45/BNC(Slide SW) (ITU-T / ANSI
) ConnectorRJ45 (EIA/TIA) CPU
SH-1(12.288MHz) FLASH 512KB SRAM
512KB DSP mounted
E1
Level control per card Software downloadable
from PBX MFC-R2 / DTMF / Pulse Dial Signaling
Type Digital R2 / Continuous EM /
Pulsed EM
TDA200 4 TDA100 2
KX-TDA0188
Level control per card -15dB to 15dB is
available for both send and receive
27
6. Cards Specification (11/20)
Slot Card (Trunk 3/6)
Card Name
Function
Card Configuration
Max use
CPU SH-1(12.288MHz) FLASH 512KB SRAM
512KB RJ45
Extension / CO trunk per port Software
downloadable form PBX Level control per
card Only S/T point Power Failure pair port
port1 for BRI CO port2 for BRI
Extension Euro-ISDN / ETS
BRI8 (BRI4)
TDA200 8 TDA100 4
(ISDN Basic)
(Q-SIG)
KX-TDA0288 (0284)
CPU SH-1(12.288MHz) FLASH 512KB SRAM
512KB PRI30 BNC/RJ45 (Slide SW) PRI23
RJ45
CO Trunk Software Downloadable from PBX Level
control per card Impedance selective
(75/120ohms) Euro-ISDN / ETS / NT1
PRI30 (PRI23)
TDA200 4 TDA100 2
(ISDN Primary)
(Q-SIG)
KX-TDA0290 (0290)
CPU SH-1(12.288MHz) Flash 512KB External
RAM 1KB Internal 128KB
External RJ45(CO trunk side)
BRI2 DHLC4
2-port ISDN basic I/F for Extension / CO
trunk per port DPT / APT / SLT / DSS / Console
card with 4-port.
TDA200 4 TDA100 2
(Ver. 1.1)
(Q-SIG)
KX-TDA
CPU SH-1(12.288MHz) Flash 512KB External
RAM 1KB Internal 128KB External RJ45 (CO
trunk side)
LCOT4DHLC4
4-port analog LCOT (polarity reversal) 1
power failure port 4-Ports DPT / APT / SLT /
DSS / Console
TDA200 4 TDA100 2
(Ver. 1.1)
KX-TDA
CID4
CO Caller ID type -gt Bell/ETSI/DTMF type
TDA200 4 TDA100 2
(Ver. 1.1)
NO CPU
KX-TDA
Level control per card -15dB to 15dB is
available for both send and receive
28
6. Cards Specification (12/20)
Slot Card (Trunk 4/6)
You are able to use the straight cable both LINE
and EXTN. And E1/T1 is also same.
29
6. Cards Specification (13/20)
Slot Card (Trunk 5/6)
Card Name
Function
Card Configuration
Max use
VoIP H.323 V.2 Supports VoIP H.323 V.2 Voice
coded G.729a, G723.1 FAXG3 64 Kbps , Physical
I/F 10 BASE-T
IP-GW4
(occupy 2 slots)
TDA200 4 TDA100 2
(Q-SIG)
KX-TDA0480
30
6. Cards Specification (14/20)
Slot Card (Trunk 6/6)
IP-GW4 Card
DSP
CPU
10 Base T Ethernet Port
SD RAM
FPGA
RS232C Maintenance Port
(Communicate Lower card and Upper card)
Upper Card( VoIP/H.323 control )
Lower Card(Communicate MPR and Upper card)
FPGA Field Programmable Gate Array
31
6. Cards Specification (15/20)
CTI-LINK Card(1/3)
Option card Installed in Free slot Option
Slot
CTI-LINK
CTI Interface Card - 10 Base-T
32
6. Cards Specification (16/20)
CTI-LINK Card(2/3)
Card Name
Function
Card Configuration
Max use
Ethernet card for CTI communication Only data
controlled Physical I/F 10BASE-T
CPU SH7709A(133MHZ) FLASH512KB SDRAM8MB
CTI-LINK
TDA200 1 TDA100 1
(LAN I/F )
KX-TDA0410
33
6. Cards Specification (17/20)
CTI-LINK Card (3/3)
LAN Controller
LED1 (Card status)
Flash Memory
LED2 (Link status)
Trans
SD RAM
RJ45

ASIC (MPR-LPR communication)
CPU
34
6. Cards Specification (18/20)
Option Card (1/3)
Option card Installed in Option Slot
OPB 3
Optional card mounting base board - 3 small
optional card space for MSG4 / DPH4 / EIO4 and
ECHO16
4-Ch. Message card - Total 8 min. Max. 64 MSG
MSG4
4 Doorphone /Door Opener card
DPH4
4 Sensor Input / 4 Relay Output card
EIO4
(Ver. 1.1)
16-Ch. Echo Cancelingcard
ECHO16
35
6. Cards Specification (19/20)
Option Card (2/3)
Card Name
Function
Card Configuration
Max use
OPB3
CPU SH1(12.288MHz) ROM 512KB(External) RAM
1KB(internal) 128KB(External)
TDA200 4 TDA100 2
Max 3 optional cards mountable Software
Downloadable from PBX
(Optional base card)
KX-TDA0190
OGM for DISA call / Queuing call / Wake
up Call / Internal hold melody DTMF
detection, CO-CO conversation DTMF
repeater functions
NO CPU Total 8 min. Max. 64 messages for
System Maximum of 3 MSG4 cards can be mounted on
the OPB3 card.
MSG4
TDA200 4 TDA100 2
(4-channels)
KX-TDA0191
NO CPU Maximum of 3 DPH4 cards can be mounted
on the OPB3 card.
DPH4
TDA200 4 TDA100 2
4-port Door-phone Door-opener card Door-phone
(T30865)
KX-TDA0161
DPH2 (-G)
NO CPU Maximum of 3 DPH2 cards can be mounted on
the OPB3 card.
TDA200 8 TDA100 4
2-port Door-phone Door-opener card For Germany
D-phone I/F
KX-TDA0162
NO CPU Maximum of 3 EIO cards can be mounted on
the OPB3 card.
EIO4
(External I/O) 4 Outputs (Relay) 4
Inputs Used for external relay / sensor
(Ver. 1.1)
TDA200 4 TDA100 2
KX-TDA0164
ECHO16
TDA200 2 TDA100 2
NO CPU Only 1 ECHO16 card can be mounted on the
OPB3 card.
16-port Echo Canceling card
KX-TDA0166
36
6. Cards Specification (20/20)
Option Card (3/3)
OPB3
DPH2
Extended
I/O

(back
side)

DPH4
Extended
I/O

MSG4

Extended

I/O
DSP
Flash
Memory

(back

side)
37
Chapter 1Hardware Configuration EU
Thank you very much !
Write a Comment
User Comments (0)
About PowerShow.com