Transcript and Presenter's Notes

Title: Fingerstick Blood Collection into a Microtainer for PNG


1
Fingerstick Blood Collection into a Microtainer
for PNG
2
Universal precautions
  • Assume that all human blood is potentially
    infectious for HIV, hepatitis, and other
    infectious agents.
  • Practice universal precautions using gloves, eye
    protection, and lab coats.
  • Always use sterile, single-use, disposable
    supplies for sample collection.

3
Finger stick procedure
  1. Place all collection materials on top of
    disposable pad. Open the alcohol swabs, gauze,
    and bandage. Have all items ready for blood
    collection. Attach the patients labels to the
    malaria slide and DBS card.

4
Finger stick procedure
  1. Put on your powder free gloves. Turn
    participants hand upward. Massage participants
    hand and lower part of the finger to increase
    blood flow.

5
Finger stick procedure
  1. Scrub the participants middle finger or ring
    finger with an alcohol swab. Dry with gauze.

6
Finger stick procedure
  1. Hold the finger in an upward position and lance
    the palm side surface of the finger (between the
    nail and the finger pad) with the lancet. Press
    firmly on the finger when making the puncture.
    Doing so will help you to obtain the amount of
    blood you need.

7
Finger stick procedure
  1. Apply slight pressure to start blood flow. Blot
    the first drop of blood on a gauze pad and
    discard in appropriate container.

8
Finger stick procedure
  1. Keep the finger in a downward position and gently
    massage it to maintain blood flow. Hold the
    Microtainer at an angle of 30 degrees below the
    collection site and use the scoop on the
    Microtainer to guide the drop into the vial. Do
    not scrape the skin. Fill the Microtainer to
    350 - 500 µL level.

9
Finger stick procedure
  1. Cap the Microtainer and gently invert it 10
    times to prevent clots from forming.

10
Finger stick procedure
  1. Apply a sterile adhesive bandage over the
    puncture site.

11
Finger stick procedure
  1. Place the label on the vial. If the label
    contains a barcode, the barcode needs to be
    vertical like a ladder when placed on the vial.
    If the barcode is not vertical, the laboratory
    will not be able to read the label. Place the
    label from left to right starting from the cap
    end and leave the graduated numbers on the tube
    visible.
  2. Properly discard all used materials.

12
Any questions?
Write a Comment
User Comments (0)