Title: SmartVFD HVAC, BYPASS, NXL, NXS Introduction


1
  • SmartVFD HVAC, BYPASS, NXL, NXS Introduction

2
Honeywell SmartVFD Today and tomorrow
SmartVFD BYPASS SmartVFD HVAC Disconnect 2-Contac
tor 3-Contactor Auto-Bypass HOA
SmartVFD COMPACT 480 VAC .5-7.5HP 208/230VAC,
1in, .25-3HP 208/230VAC, 3in .25-3HP 115VAC,
1in .15-1.5HP 575Vac, 1HP-7.5HP NEMA1 Kit Modbus
Std
  • SmartVFD HVAC
  • 480 VAC 1.5-250HP
  • 230VAC 1125HP
  • 575VAC - 1-150HP
  • Graphic Interface
  • Std fieldbus protocals

3
SmartVFD HVAC
  • Intuitive Interface
  • Easy Commissioning
  • Standard Communication
  • Reliable Protection
  • Effective Operation/Monitoring

The SmartVFD for Smart Buildings
4
Intuitive Interface
  • High resolution
  • Intuitive commissioning
  • Manual in keypad
  • Help screens
  • Real time clock
  • Local/Remote Button
  • Memory in keypad

Intuitive, Effective, Consistant SMART
5
Easy Communications
  • Standard
  • RS485
  • BACnet
  • N2
  • Modbus
  • Ethernet
  • Modbus/TCP
  • BACnet/IP
  • Option Cards
  • LonWorks
  • Profibus
  • CANopen
  • DeviceNet
  • Ethernet

Built-in Communications
6
Built-In Protection
  • DC Choke
  • Built in resistors for upfront protection
  • Varnished boards
  • RFI filter standard
  • Built in Fan
  • NEMA12 extra fan

Harmonic, RFI, Environmental Protection
7
SMART Software
  • Start-up Wizard Pump/Fan
  • Power loss ride through
  • Fire mode
  • Pump and Fan Cascade
  • Ramp Time Optimizer
  • Maintenance Counters
  • Pump Soft Fill
  • 2 PID Controllers

The SmartVFD for Smart Buildings
8
SmartVFD BYPASS
  • Low total installed cost
  • Compact size
  • Easy component access
  • NEMA 1, 12, 3R
  • All configurations
  • Disconnect
  • 2-contactor
  • 3-contactor
  • 3-contactor with AutoBypass, HOA

9
Features
10
Bypass Options
11
Smart VFD HVAC Mechanical Construction MR4
  • Panel
  • Main DC Fan
  • IP54 Fan
  • Rectifying ,
  • brake and IGBT
  • Heatsink
  • DC Choke
  • Control
  • assembly
  • Power Board
  • IP21 or 54
  • Plates and
  • sealing
  • DC Capacitor
  • GND Plates

12
Smart VFD HVAC Cabling
  • Sealing
  • No throughput clamps needed in IP21
  • No throughput clamps needed in IP54
  • EMC
  • 360 grounding with easy clamps inside the
    drive (consertrig)
  • Input cables
  • MCMK no shield needed
  • Motor cables
  • Max lenght
  • MR4 100m
  • MR5 and MR6 150m
  • MR7 200m
  • C2 MCCMK and C3/IT MCMK
  • Grounding
  • 2 PE wires needs to be connected to ground to
    fulfill EN61800-5-1.
  • Fuses and cable sizes MR4-9
  • Chapter 4.1.1.X in installation manual

13
Smart VFD HVAC Fieldbus RS-485
  • RS485 2 Wires always included in Vacon 100 HVAC
  • BACnet
  • N2
  • Modbus
  • RS485 4 Wires
  • Keypad
  • PC Tools
  • RS-485 4W
  • RS-485 2W

14
Smart VFD HVAC Fieldbus Ethernet
  • Ethernet module is integrated to the main
    processor
  • Supported General Protocols
  • TCP/IP (basic protocol)
  • DHCP, AUTOIP, IPConfig
  • FTP (Future Option)
  • HTTP, simple web browser interface (Future
    option)
  • Supported Industrial Protocols
  • Modbus/TCP
  • BacNet IP
  • Vacon HMI protocol (for PC tool usage)
  • Ethernet/IP and Profinet (Future option)
  • Cable max lenght 100m (to switch)
  • Ethernet

15
Smart VFD HVAC Control Board
  • ARM9 Processor (200MHz)
  • Flash Memory 32Mb
  • RAM Memory 128Mb

16